New application of polymer gels in medical radiation dosimetry: Plasmonic sensors

被引:11
|
作者
Adliene, Diana [1 ]
Urbonavicius, Benas Gabrielis [1 ]
Laurikaitiene, Jurgita [1 ]
Puiso, Judita [1 ]
机构
[1] Kaunas Univ Technol, Phys Dept, Studentu Str 50, Kaunas, Lithuania
关键词
X-ray irradiation; Gel dosimeters; Surface plasmon resonance; Plasmonic sensor; Dosimetry system; RESONANCE; DETECTORS; FRICKE; CT;
D O I
10.1016/j.radphyschem.2019.108609
中图分类号
O64 [物理化学(理论化学)、化学物理学];
学科分类号
070304 ; 081704 ;
摘要
Polymer gels are amongst the most promising future dosimetric tools for medical applications, since irradiated gels are capable to represent a phantom and a dosimeter with a 3D-dose distribution measurement capability and biological tissue equivalency in one. High spatial resolution of these gels but limited dose sensitivity, especially in low dose region, as well complicated and time consuming read out methods are the main issues needing improvement. Operating principle of plasmonic sensors which are commonly used in biotechnology to assess the concentration and reaction rate of various organic compounds, is based on the excitation of strong free electron oscillations (surface plasmon resonance, SPR) in the boundary layer between metal and dielectric using polarized light and measurement of the refracted light characteristics. Plasmonic sensors stand out from the other sensing technologies due to their high resolution and relatively low uncertainties. Combination of plasmonic sensors' characteristics and capabilities of dosimetric gels is key when developing dosimetric gel based SPR sensors for point dose measurements and corresponding relatively simple, however sensitive, in-house made dosimetric system working in angular mode, all of which is presented in this paper. Developed plasmonic sensor itself comprised out of Au diffraction grating, extracted from commercial optical media disc, spin-coated with a thin dosimetric gel (nPAG or VIPET) layer. Fabrication procedure of the plasmonic sensor and creation of the corresponding optical read out system are discussed in this paper. Irradiation experiments performed with dosimetric gel based SPR sensor (point dosimeter) have shown the feasibility of this new type dosimetry system to measure low absorbed doses (up to 5Gy) and revealed the potential of this system to perform measurements with the dosimetric sensitivity up to two times higher as compared to other known optical dose evaluation methods. Key aspects regarding sensitivity and resolution of plasmonic dosimeters are also discussed.
引用
收藏
页数:7
相关论文
共 50 条
  • [21] Polymer applications in the dosimetry of ionizing radiation
    Stuglik, Z
    POLIMERY, 1997, 42 (03) : 156 - 161
  • [22] THE APPLICATION OF COMMERCIAL RED PERSPEX AND OTHER POLYMER DYE SYSTEMS TO RADIATION DOSIMETRY
    WHITTAKER, B
    BRITISH JOURNAL OF RADIOLOGY, 1963, 36 (430): : 779 - 779
  • [23] Radiation dosimetry properties of smartphone CMOS sensors
    Van Hoey, Olivier
    Salavrakos, Alexia
    Marques, Antonio
    Nagao, Alexandre
    Willems, Ruben
    Vanhavere, Filip
    Cauwels, Vanessa
    Nascimento, Luana F.
    RADIATION PROTECTION DOSIMETRY, 2016, 168 (03) : 314 - 321
  • [24] Radiochromic film for medical radiation dosimetry
    Butson, MJ
    Yu, PKN
    Cheung, T
    Metcalfe, P
    MATERIALS SCIENCE & ENGINEERING R-REPORTS, 2003, 41 (3-5): : 61 - 120
  • [25] Radiation dosimetry for diagnostic medical exposures
    Martin, C. J.
    RADIATION PROTECTION DOSIMETRY, 2008, 128 (04) : 389 - 412
  • [26] Medical Radiation Dosimetry: Concepts and Needs
    Kron, Tomas
    CONCEPTS AND TRENDS IN MEDICAL RADIATION DOSIMETRY, 2011, 1345 : 24 - 35
  • [27] Absolute dosimetry with polymer gels-a TLD reference system
    Mann, P.
    Schwahofer, A.
    Karger, C. P.
    PHYSICS IN MEDICINE AND BIOLOGY, 2019, 64 (04):
  • [28] Application of radiation track in radiation biophysics and dosimetry
    Nikjoo, H
    Uehara, S
    ATOMIC AND MOLECULAR DATA AND THEIR APPLICATIONS, 2002, 636 : 14 - 22
  • [29] Size Separation of polymer gels using Plasmonic Optical Tweezers
    Wake, Sayuri
    Shoji, Tatsuya
    Tsuboi, Yasuyuki
    OPTICAL MANIPULATION AND STRUCTURED MATERIALS CONFERENCE 2021, 2021, 11926
  • [30] On the measurement of radiation isocenter for medical accelerators using 3D polymer gel dosimetry. Introduction, application, and good practices
    Kozicki, Marek
    Maras, Piotr
    MEASUREMENT, 2023, 221