Reducing User Discomfort in Direct Load Control of Domestic Water Heaters

被引:0
作者
Belov, Alexander [1 ]
Vasenev, Alexandr [2 ]
Havinga, Paul J. M. [1 ]
Meratnia, Nirvana [1 ]
van der Zwaag, Berend Jan [3 ]
机构
[1] Univ Twente, Pervas Syst Res Grp, POB 217, NL-7500 AE Enschede, Netherlands
[2] Univ Twente, Serv Cybersecur & Safety Res Grp, NL-7500 AE Enschede, Netherlands
[3] Adapt Syst, Hengelo O, Netherlands
来源
2015 IEEE INNOVATIVE SMART GRID TECHNOLOGIES - ASIA (ISGT ASIA) | 2015年
关键词
Power system management; Power demand; Control systems; Optimal control; Power system stability; CONTROL STRATEGIES; MODEL;
D O I
暂无
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
Direct Load Control (DLC) is an effective instrument for achieving a guaranteed load curtailment. Unfortunately, if a customer considers that personal discomfort outweighs money savings after DLC shutting down of home appliances, DLC solution can be rejected. This paper proposes the way to remediate customer comfort concerns by pre-storing additional energy in electric loads before their disconnection from the grid. We take electric tank water heaters as an illustrative example of residential loads with storage. To illuminate our approach we first show how to balance electric consumption for pre-storing with user thermal discomfort for a single water heater. Then, we illustrate how the approach can be scaled-up to a multiple-boiler scenario, when ten remotely controlled boilers act next to fifty non-controlled boilers. The simulations for the latter case show that the expected user thermal discomfort can be significantly reduced at the cost of a reasonable increase of electricity demand preceding DLC event.
引用
收藏
页数:6
相关论文
共 23 条
  • [1] A summary of demand response in electricity markets
    Albadi, M. H.
    El-Saadany, E. F.
    [J]. ELECTRIC POWER SYSTEMS RESEARCH, 2008, 78 (11) : 1989 - 1996
  • [2] ALIZADEH M, 2013, P 51 ANN ALL C COMM, P1029
  • [3] Bartam J., 2007, LEGIONELLA PREVENTIO
  • [4] Belov Alexander., 2014, Journal of Engineering Applied Sciences, V9, P2106
  • [5] Borenstein A, 2002, CTR STUDY ENERGY MAR, V103
  • [6] Development of a Monte Carlo based aggregate model for residential electric water heater loads
    Dolan, PS
    Nehrir, MH
    Gerez, V
    [J]. ELECTRIC POWER SYSTEMS RESEARCH, 1996, 36 (01) : 29 - 35
  • [7] Appliance Commitment for Household Load Scheduling
    Du, Pengwei
    Lu, Ning
    [J]. IEEE TRANSACTIONS ON SMART GRID, 2011, 2 (02) : 411 - 419
  • [8] Elgazzar K., P 2009 IEEE CAN C EL, P1141
  • [9] Frincu M., P 2014 IEEE C TECHN, P61
  • [10] A multiple objective approach to direct load control using an interactive evolutionary algorithm
    Gomes, A.
    Antunes, C. H.
    Martins, A. G.
    [J]. IEEE TRANSACTIONS ON POWER SYSTEMS, 2007, 22 (03) : 1004 - 1011