Accuracy of linear measurements using three imaging modalities: two lateral cephalograms and one 3D model from CBCT data

被引:43
|
作者
Pittayapat, Pisha [1 ,2 ,3 ]
Bornstein, Michael M. [1 ,2 ,4 ]
Nozu Imada, Thais Sumie [5 ]
Coucke, Wim [6 ]
Lambrichts, Ivo [7 ]
Jacobs, Reinhilde [1 ,2 ]
机构
[1] Univ Leuven, Fac Med, Dept Imaging & Pathol, OIC,OMFS IMPATH Res Grp, B-3000 Leuven, Belgium
[2] Univ Hosp Leuven, Oral & Maxillofacial Surg, B-3000 Leuven, Belgium
[3] Chulalongkorn Univ, Fac Dent, Dept Radiol, Bangkok, Thailand
[4] Univ Bern, Sch Dent Med, Dept Oral Surg & Stomatol, Bern, Switzerland
[5] Univ Sao Paulo FOB USP, Dept Stomatol, Bauru Sch Dent, Sao Paulo, Brazil
[6] Sci Inst Publ Hlth, Dept Biol Clin, Brussels, Belgium
[7] Hasselt Univ, Lab Morphol, Biomed Res Inst, Diepenbeek, Belgium
关键词
BEAM COMPUTED-TOMOGRAPHY; 3-DIMENSIONAL IMAGES; RELIABILITY; IDENTIFICATION;
D O I
10.1093/ejo/cju036
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Background: The aim of this study was to evaluate the accuracy of linear measurements on three imaging modalities: lateral cephalograms from a cephalometric machine with a 3 m source-to-mid-sagittal-plane distance (SMD), from a machine with 1.5 m SMD and 3D models from cone-beam computed tomography (CBCT) data. Methods: Twenty-one dry human skulls were used. Lateral cephalograms were taken, using two cephalometric devices: one with a 3 m SMD and one with a 1.5 m SMD. CBCT scans were taken by 3D Accuitomo (R) 170, and 3D surface models were created in Maxilim (R) software. Thirteen linear measurements were completed twice by two observers with a 4 week interval. Direct physical measurements by a digital calliper were defined as the gold standard. Statistical analysis was performed. Results: Nasion-Point A was significantly different from the gold standard in all methods. More statistically significant differences were found on the measurements of the 3 m SMD cephalograms in comparison to the other methods. Intra-and inter-observer agreement based on 3D measurements was slightly better than others. Limitations: Dry human skulls without soft tissues were used. Therefore, the results have to be interpreted with caution, as they do not fully represent clinical conditions. Conclusions: 3D measurements resulted in a better observer agreement. The accuracy of the measurements based on CBCT and 1.5 m SMD cephalogram was better than a 3 m SMD cephalogram. These findings demonstrated the linear measurements accuracy and reliability of 3D measurements based on CBCT data when compared to 2D techniques. Future studies should focus on the implementation of 3D cephalometry in clinical practice.
引用
收藏
页码:202 / 208
页数:7
相关论文
共 9 条
  • [1] Accuracy and reliability of craniometric measurements on lateral cephalometry and 3D measurements on CBCT scans
    Gribel, Bruno Frazao
    Gribel, Marcos Nadler
    Frazao, Diogo Campos
    McNamara, James A., Jr.
    Manzi, Flavio Ricardo
    ANGLE ORTHODONTIST, 2011, 81 (01) : 26 - 35
  • [2] Comparison of linear and angular measurements in CBCT scans using 2D and 3D rendering software
    Aksoy, Secil
    Kelahmet, Umay
    Hincal, Evren
    Oz, Ulas
    Orhan, Kaan
    BIOTECHNOLOGY & BIOTECHNOLOGICAL EQUIPMENT, 2016, 30 (04) : 777 - 784
  • [3] Comparative study of reproducibility and accuracy in measuring mesiodistal tooth sizes using three different methods: 2D digital, 3D CBCT, and 3D CBCT segmented
    Hernandez, Yanira
    Tarazona, Beatriz
    Zamora, Natalia
    Cibrian, Rosa
    Luis Gandia, Jose
    Paredes, Vanessa
    ORAL RADIOLOGY, 2015, 31 (03) : 165 - 172
  • [4] 3D accuracy of deciduous tooth model reconstructed from CBCT scan
    Li, Hongbo
    Liu, Lin
    Gao, Yuxuan
    Shi, Xiaowei
    MEASUREMENT TECHNOLOGY AND ITS APPLICATION, PTS 1 AND 2, 2013, 239-240 : 798 - +
  • [5] Analysis of linear measurements on 3D surface models using CBCT data segmentation obtained by automatic standard pre-set thresholds in two segmentation software programs: an in vitro study
    Poleti, Marcelo Lupion
    Freire Fernandes, Thais Maria
    Pagin, Otavio
    Moretti, Marcela Rodrigues
    Fischer Rubira-Bullen, Izabel Regina
    CLINICAL ORAL INVESTIGATIONS, 2016, 20 (01) : 179 - 185
  • [6] Determining the Accuracy of the Mandibular Canal Region in 3D Biomodels Fabricated from CBCT Scanned Data: A Cadaveric Study
    Abd Fattah, Syed Yusoff Alzawawi Syed
    Hariri, Firdaus
    Nambiar, Phrabhakaran
    Abu Bakar, Zulkiflee
    Rahman, Zainal Ariff Abdul
    CURRENT MEDICAL IMAGING, 2019, 15 (07) : 645 - 653
  • [7] Accuracy of Linear Craniometric Measurements Obtained from Laser Scanning Created 3D Models of Dry Skulls
    Toneva, Diana
    Nikolova, Silviya
    Georgiev, Ivan
    Tchorbadjieff, Assen
    ADVANCED COMPUTING IN INDUSTRIAL MATHEMATICS, 2017, 681 : 215 - 229
  • [8] One Step before 3D Printing-Evaluation of Imaging Software Accuracy for 3-Dimensional Analysis of the Mandible: A Comparative Study Using a Surface-to-Surface Matching Technique
    Lo Giudice, Antonino
    Ronsivalle, Vincenzo
    Grippaudo, Cristina
    Lucchese, Alessandra
    Muraglie, Simone
    Lagravere, Manuel O.
    Isola, Gaetano
    MATERIALS, 2020, 13 (12)
  • [9] Sensing and imaging of exosomal CD26 secreted from cancer cells and 3D colorectal tumor model using a novel near-infrared fluorogenic probe
    Wang, Dan-Dan
    Qian, Xing-Kai
    Li, Hong-Xin
    Jia, Gui-Hua
    Jin, Qiang
    Luan, Xin
    Zhu, Ya-Di
    Wang, Yi-Nan
    Huang, Jian
    Zou, Li-Wei
    Ge, Guang-Bo
    Yang, Ling
    MATERIALS SCIENCE AND ENGINEERING C-MATERIALS FOR BIOLOGICAL APPLICATIONS, 2021, 130