Multifixation campimetry on line: a perimeter for the detection of visual field loss using the internet

被引:9
|
作者
Damato, B [1 ]
Groenewald, C [1 ]
机构
[1] Royal Liverpool Univ Hosp, St Pauls Eye Unit, Liverpool L7 8XP, Merseyside, England
关键词
D O I
10.1136/bjo.87.10.1296
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
More widespread perimetry would improve opportunities for preventing visual handicap from ocular and intracranial diseases, some of which are life threatening. With internet access becoming more ubiquitous, the authors have developed multifixation campimetry on line, for qualified practitioners and lay individuals around the world, free of charge.
引用
收藏
页码:1296 / 1298
页数:3
相关论文
共 50 条
  • [21] Detection and resolution thresholds in the binocular visual field using parallel line targets
    Wakayama, A
    Matsumoto, C
    Ohmure, K
    Matsumoto, F
    Shimomura, Y
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2004, 45 : U422 - U422
  • [22] USE OF FIELDMASTER AUTOMATED PERIMETER FOR THE DETECTION OF EARLY VISUAL-FIELD CHANGES IN GLAUCOMA
    HONG, C
    KITAZAWA, Y
    SHIRATO, S
    INTERNATIONAL OPHTHALMOLOGY, 1982, 4 (03) : 151 - 156
  • [23] Validation and Reproducibility of the Heidelberg Edge Perimeter in the Detection of Visual Field Defects in Glaucoma Participants
    Lam, Jonathan Maxwell
    Hark, Lisa A.
    Myers, Jonathan S.
    Katz, L. Jay
    Siraj, Safa
    Waisbourd, Michael
    Gogte, Priyanka
    Cui, Qi J.
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2017, 58 (08)
  • [24] Simplified automatic method for measuring the visual field using the perimeter ZERK 1
    Robert Koprowski
    Paweł Kasprowski
    Marek Rzendkowski
    BioMedical Engineering OnLine, 15
  • [25] Simplified automatic method for measuring the visual field using the perimeter ZERK 1
    Koprowski, Robert
    Kasprowski, Pawel
    Rzendkowski, Marek
    BIOMEDICAL ENGINEERING ONLINE, 2016, 15 : 1
  • [26] ERG campimetry using a multi-input stimulation technique for mapping of retinal function in the central visual field
    Kretschmann, U
    Ruther, K
    Usui, T
    Zrenner, E
    OPHTHALMIC RESEARCH, 1996, 28 (05) : 303 - 311
  • [27] Detection of progressive visual field loss by suprathreshold perimetry
    Spry, PGD
    Henson, DB
    Sparrow, JM
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 1997, 38 (04) : 2656 - 2656
  • [28] The performance of iPad-based noise-field perimeter versus Humphrey Field Analyser in detecting glaucomatous visual field loss
    Ding, Jianbin
    Tecson, Ivan C.
    Ang, Bryan C. H.
    Chiew, Wenqi
    Chua, Chunhau
    Yip, Leonard W. L.
    EYE, 2022, 36 (04) : 800 - 811
  • [29] The performance of iPad-based noise-field perimeter versus Humphrey Field Analyser in detecting glaucomatous visual field loss
    Jianbin Ding
    Ivan C. Tecson
    Bryan C. H. Ang
    Wenqi Chiew
    Chunhau Chua
    Leonard W. L. Yip
    Eye, 2022, 36 : 800 - 811