Quality assurance of malaria rapid diagnostic tests used for routine patient care in rural Tanzania: microscopy versus real-time polymerase chain reaction

被引:12
作者
Masanja, Irene M. [1 ]
McMorrow, Meredith L. [2 ,3 ]
Maganga, Mussa B. [1 ]
Sumari, Debora [1 ]
Udhayakumar, Venkatachalam [2 ]
McElroy, Peter D. [2 ,4 ]
Kachur, S. Patrick [2 ,3 ]
Lucchi, Naomi W. [2 ]
机构
[1] Ifakara Hlth Inst, Dar Es Salaam, Tanzania
[2] US Ctr Dis Control & Prevent, Ctr Global Hlth, Malaria Branch, Atlanta, GA USA
[3] US PHS, Rockville, MD USA
[4] US President Malaria Initiat PMI, Dar Es Salaam, Tanzania
关键词
Rapid diagnostic test (RDT); Microscopy; qPCR; Quality assurance (QA); Routine malaria tests; PLASMODIUM-FALCIPARUM MALARIA; TRANSMISSION; MISDIAGNOSIS; PERFORMANCE; THICK; HRP-2; AREA; PCR; AGE;
D O I
10.1186/s12936-015-0597-3
中图分类号
R51 [传染病];
学科分类号
100401 ;
摘要
Background: The World Health Organization (WHO) recommends parasitologic confirmation of suspected malaria cases before treatment. Due to the limited availability of quality microscopy services, this recommendation has become scalable following increased use of antigen-detecting malaria rapid diagnostic tests (RDTs) in many malaria-endemic countries. This study was carried out to monitor quality of RDT performance in selected health facilities using two quality assurance (QA) methods: reference microscopy and detection of parasite DNA by real-time quantitative polymerase chain reaction (qPCR) on dried blood spots (DBS). Methods: Blood samples for QA were collected from patients undergoing RDT for diagnostic confirmation of malaria during two to three consecutive days per month in 12 health facilities in rural Tanzania. Stained blood smears (BS) were first examined at the district hospitals (BS1) and then at a reference laboratory (BS2). Discordant BS1 and BS2 results prompted a third examination. Molecular analysis was carried out at the Ifakara Health Institute laboratory in Bagamoyo. Results: Malaria RDTs had a higher positivity rate (6.5%) than qPCR (4.2%) or microscopy (2.9% for BS1 and 2.5% for BS2). Poor correlation was observed between RDT and BS results: BS1 (K = 0.5), BS2 (K = 0.43) and qPCR (K = 0.45), challenging the utility of these tests for RDT QA. In addition, many challenges related to qPCR processing were recorded and long delays in obtaining QA test results for both microscopy and qPCR. Conclusions: Overall there was limited agreement among the three diagnostic approaches and neither microscopy nor qPCR appear to be good QA options for RDTs under field conditions.
引用
收藏
页数:7
相关论文
共 42 条
[1]   Dried Plasmodium falciparum-infected samples as positive controls for malaria rapid diagnostic tests [J].
Aidoo, Michael ;
Patel, Jaymin C. ;
Barnwell, John W. .
MALARIA JOURNAL, 2012, 11
[2]   Reducing malaria misdiagnosis: the importance of correctly interpreting ParaCheck Pf® "faint test bands" in a low transmission area of Tanzania [J].
Allen, Lisa K. ;
Hatfield, Jennifer M. ;
DeVetten, Giselle ;
Ho, Jeremy C. ;
Manyama, Mange .
BMC INFECTIOUS DISEASES, 2011, 11
[3]  
[Anonymous], MAL RAP DIAGN TEST P
[4]  
[Anonymous], UPD WHO PROC SEL US
[5]  
[Anonymous], MAL RAP DIAGN TEST P
[6]  
[Anonymous], T R SOC TROP MED HYG
[7]  
[Anonymous], 2010, Guidelines for the treatment of Malaria, DOI DOI 10.1080/03630269.2023.2168201
[8]  
[Anonymous], TANZ FIG 2010
[9]   Does the availability of blood slide microscopy for malaria at health centers improve the management of persons with fever in Zambia? [J].
Barat, L ;
Chipipa, J ;
Kolczak, M ;
Sukwa, T .
AMERICAN JOURNAL OF TROPICAL MEDICINE AND HYGIENE, 1999, 60 (06) :1024-1030
[10]   Thick blood film examination for Plasmodium falciparum malaria has reduced sensitivity and underestimates parasite density [J].
Bejon, Philip ;
Andrews, Laura ;
Hunt-Cooke, Angela ;
Sanderson, Frances ;
Gilbert, Sarah C. ;
Hill, Adrian V. S. .
MALARIA JOURNAL, 2006, 5 (1)