Four- and eight-channel aortoiliac CT angiography: A comparative study

被引:3
作者
Karcaaltincaba, M
Foley, D
机构
[1] Med Coll Wisconsin, Dept Radiol, Milwaukee, WI 53226 USA
[2] Hacettepe Univ, Dept Radiol, Sch Med, TR-06100 Ankara, Turkey
关键词
abdominal aortic aneurysm; aortoiliac; CT angiography; multidetector CT systems;
D O I
10.1007/s00270-003-0131-9
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Purpose: To compare performance parameters, contrast material load and radiation dose in a patient cohort having aortoiliac CT angiography using 4- and 8-channel multidetector CT (MDCT) systems. Methods: Eighteen patients with abdominal aortic aneurysms underwent initial 4-channel and follow-up 8-channel MDCT angiography. Both the 4- and 8-channel MDCT systems utilized a matrix detector of 16 x 1.25 mm rows. Scan coverage included the abdominal aorta and iliac arteries to the level of the proximal femoral arteries. For 4-channel MDCT, nominal slice thickness and beam pitch were 1.25 mm and 1.5, respectively, and for 8-channel MDCT they were 1.25 mm and 1.35 or 1.65 respectively. Scan duration, iodinated contrast material load and mean aortoiliac attenuation were compared retrospectively. Comparative radiation dose measurements for 4- and 8-channel MDCT were obtained using a multiple scan average dose technique on an abdominal phantom. Results: Compared with 4-channel MDCT, 8-channel MDCT aortoiliac angiography was performed with equivalent collimation, decreased contrast load (mean 45% decrease: 144 ml versus 83 ml of 300 mg iodine/ml contrast material) and decreased acquisition time (mean 51% shorter: 34.4 sec versus 16.9 sec) without a significant change in mean aortic enhancement (299 HU versus 300 HU, p > 0.05). Radiation dose was 2 rad for the 4-channel system and 2/1.5 rad for the 8-channel system at 1.35/1.65 pitch respectively. Conclusion: Compared with 4-channel MDCT, aortoiliac CT angiography with 8-channel MDCT produces equivalent z-axis resolution with decreased contrast load and acquisition time without increased radiation exposure.
引用
收藏
页码:169 / 172
页数:4
相关论文
共 11 条
[1]   Eight-channel multidetector computed tomography: Unique potential for pediatric chest: Computed tomography angiography [J].
Denecke, T ;
Frush, DP ;
Li, J .
JOURNAL OF THORACIC IMAGING, 2002, 17 (04) :306-309
[2]   From the RSNA refresher courses - CT angiography: Clinical applications in the abdomen [J].
Fishman, EK .
RADIOGRAPHICS, 2001, 21 :S3-S16
[3]  
Foley WD, 2003, J COMPUT ASSIST TOMO, V27, pS23, DOI 10.1097/00004728-200305001-00006
[4]   Four multidetector-row helical CT: Image quality and volume coverage speed [J].
Hu, H ;
He, HD ;
Foley, WD ;
Fox, SH .
RADIOLOGY, 2000, 215 (01) :55-62
[5]   Gadolinium-enhanced multidetector CT angiography of the thoracoabdominal aorta [J].
Karcaaltincaba, M ;
Foley, WD .
JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2002, 26 (06) :875-878
[6]   Original report - Dose and pitch relationship for a particular multislice CT scanner [J].
Mahesh, M ;
Scatarige, JC ;
Cooper, J ;
Fishman, EK .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2001, 177 (06) :1273-1275
[7]   Multislice CT angiography [J].
Prokop, M .
EUROPEAN JOURNAL OF RADIOLOGY, 2000, 36 (02) :86-96
[8]   Are Greek letter social organizations a factor in undergraduates' perceptions of international instructors? [J].
Rubin, DL ;
Ainsworth, S ;
Cho, E ;
Turk, D ;
Winn, L .
INTERNATIONAL JOURNAL OF INTERCULTURAL RELATIONS, 1999, 23 (01) :1-12
[9]   Aorta and iliac arteries: Single versus multiple detector-row helical CT angiography [J].
Rubin, GD ;
Shiau, MC ;
Leung, AN ;
Kee, ST ;
Logan, LJ ;
Sofilos, MC .
RADIOLOGY, 2000, 215 (03) :670-676
[10]   Cost identification of abdominal aortic aneurysm imaging by using time and motion analyses [J].
Rubin, GD ;
Armerding, MD ;
Dake, MD ;
Napel, S .
RADIOLOGY, 2000, 215 (01) :63-70