Relations between the bone density values from computerized tomography, and implant stability parameters:: a clinical study of 230 regular platform implants

被引:171
作者
Turkyilmaz, Ilser
Tumer, Celal
Ozbek, Esma Nida
Toezuem, Tolga F.
机构
[1] Ohio State Univ, Coll Dent, Dept Restorat & Prosthet Dent, Columbus, OH 43218 USA
[2] Hacettepe Univ, Fac Dent, Dept Oral & Maxillofacial Surg, TR-06100 Ankara, Turkey
[3] Baskent Univ, Fac Dent, Dept Periodontol, TR-06490 Ankara, Turkey
[4] Hacettepe Univ, Fac Dent, Dept Periodontol, Ankara, Turkey
关键词
bone density; computerized tomography; CT; dental implants; Hounsfield unit; implant stability; insertion torque; resonance frequency analysis;
D O I
10.1111/j.1600-051X.2007.01112.x
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Aims: The objective of this study was to determine the relationship between bone density, insertion torque, and implant stability at implant placement. Materials and Methods: One-hundred and eight patients were treated with 230 Branemark System implants. A computerized tomography (CT) machine was used for pre-operative evaluation of the jaw bone for each patient. The maximum insertion torque values were recorded with the OsseoCare equipment. Implant stability measurements were performed with the Osstell machine for only 142 implants. Results: The mean bone density and insertion torque values were 721 254 Hounsfield unit (HU) and 39.1 +/- 7 N cm for 230 implants, and the correlation was significant (r = 0.664, p < 0.001). The mean bone density, insertion torque, and resonance frequency analysis values were 751 +/- 257 HU, 39.4 +/- 7 Nc m, and 70.5 +/- 7 implant stability quotient (ISQ), respectively, for 142 implants. Statistically significant correlations were found between bone density and insertion torque values (p < 0.001); bone density and ISQ values (p < 0.001); and insertion torque and ISQ values (p < 0.001). Conclusion: The bone density values from pre-operative CT examination may provide an objective assessment of bone quality, and significant correlations between bone density and implant stability parameters may help clinicians to predict primary stability before implant insertion.
引用
收藏
页码:716 / 722
页数:7
相关论文
共 40 条
[1]  
Aranyarachkul P, 2005, INT J ORAL MAX IMPL, V20, P416
[2]   Correlation of insertion torques with bone mineral density from dental quantitative CT in the mandible [J].
Beer, A ;
Gahleitner, A ;
Holm, A ;
Tschabitscher, M ;
Homolka, P .
CLINICAL ORAL IMPLANTS RESEARCH, 2003, 14 (05) :616-620
[3]  
BRINEMARK PI, 1985, TISSUE INTEGRATED PR, P11
[4]  
da Cunha HA, 2004, INT J ORAL MAX IMPL, V19, P578
[5]  
De Backer H, 2006, INT J PROSTHODONT, V19, P567
[6]   A retrospective analysis of factors associated with multiple implant failures in maxillae [J].
Ekfeldt, A ;
Christiansson, U ;
Eriksson, T ;
Lindén, U ;
Lundqvist, S ;
Rundcrantz, T ;
Johansson, LÅ ;
Nilner, K ;
Billström, C .
CLINICAL ORAL IMPLANTS RESEARCH, 2001, 12 (05) :462-467
[7]  
Engfors Ingela, 2004, Clin Implant Dent Relat Res, V6, P190, DOI 10.1111/j.1708-8208.2004.tb00035.x
[8]  
Engquist B, 1988, Int J Oral Maxillofac Implants, V3, P129
[9]   Three-dimensional morphometric analysis of human cadaver bone: microstructural data from maxilla and mandible [J].
Fanuscu, MI ;
Chang, TL .
CLINICAL ORAL IMPLANTS RESEARCH, 2004, 15 (02) :213-218
[10]  
Friberg B, 1999, INT J ORAL MAX SURG, V28, P297