A Bidimensional System of Facial Movement Analysis Conception and Reliability in Adults

被引:15
作者
Baude, Marjolaine [1 ]
Hutin, Emilie [1 ]
Gracies, Jean-Michel [1 ]
机构
[1] Hosp Univ Henri Mondor, Lab Analyse & Restaurat Mouvement, Serv Reeduc Neurolocomotrice, F-94010 Creteil, France
关键词
3-DIMENSIONAL VIDEO ANALYSIS; MOTION ANALYSIS; HOUSE-BRACKMANN; KAPPA-COEFFICIENTS; MEASUREMENT TOOL; GRADING SYSTEMS; COMPUTER-SYSTEM; PARALYSIS; QUANTIFICATION; EXPRESSIONS;
D O I
10.1155/2015/812961
中图分类号
Q81 [生物工程学(生物技术)]; Q93 [微生物学];
学科分类号
071005 ; 0836 ; 090102 ; 100705 ;
摘要
Objective. To design a bidimensional facial movement measuring tool and study its reliability. Methods. We utilized the free video-analysis software Kinovea that can track preselected points during movements and measure two-point distances off-line. Three raters positioned facial markers on 10 healthy individuals and video-taped them during maximal bilateral contractions of frontalis, corrugator, orbicularis oculi, zygomaticus, orbicularis oris, and buccinator, on two occasions. Each rater also analyzed the first video twice, one week apart. For each muscle, intrarater reliability was measured by percent agreements (PA) and intraclass correlation coefficients (ICC) between two assessments of the same video one week apart and between assessments of two videos collected one week apart. Interrater reliability was measured by PA, ICC, and coefficients of variation (CV) between assessments of the first video-recording by the three raters. Results. Intrarater and interrater reliabilities were good to excellent for frontalis (PA and ICC > 70%; CV < 15%), moderate for orbicularis oculi, zygomaticus, and orbicularis oris, and poor for corrugator and buccinators. Discussion. Without formal prior training, the proposed method was reliable for frontalis in healthy subjects. Improved marker selection, training sessions, and testing reliability in patients with facial paresis may enhance reliability for orbicularis oculi, zygomaticus, and orbicularis oris.
引用
收藏
页数:8
相关论文
共 49 条
[1]  
Aiguade R., 2013, KINESITHERAPIE REV, V13, P58
[2]  
Baude M., 2012, APRM, V55, pe295
[3]   Agreement between the Sunnybrook, House-Brackmann, and Yanagihara facial nerve grading systems in Bell's palsy [J].
Berg, T ;
Jonsson, L ;
Engström, M .
OTOLOGY & NEUROTOLOGY, 2004, 25 (06) :1020-1026
[4]   A NOTE ON THE USE OF THE INTRACLASS CORRELATION-COEFFICIENT IN THE EVALUATION OF AGREEMENT BETWEEN 2 METHODS OF MEASUREMENT [J].
BLAND, JM ;
ALTMAN, DG .
COMPUTERS IN BIOLOGY AND MEDICINE, 1990, 20 (05) :337-340
[5]   2X2 KAPPA-COEFFICIENTS - MEASURES OF AGREEMENT OR ASSOCIATION [J].
BLOCH, DA ;
KRAEMER, HC .
BIOMETRICS, 1989, 45 (01) :269-287
[6]  
Bruyneel A. V., 2013, KINESITHERAPIE REV, V13, P30
[7]   Threshold of Visual Perception of Facial Asymmetry in a Facial Paralysis Model [J].
Chu, Eugene A. ;
Farrag, Tarik Y. ;
Ishii, Lisa E. ;
Byrne, Patrick J. .
ARCHIVES OF FACIAL PLASTIC SURGERY, 2011, 13 (01) :14-19
[8]   Quantification of the three-dimensional displacement of normal facial movement [J].
Coulson, SE ;
Croxson, GR ;
Gilleard, WL .
ANNALS OF OTOLOGY RHINOLOGY AND LARYNGOLOGY, 2000, 109 (05) :478-483
[9]   Reliability of the "Sydney," "Sunnybrook," and "House Brackmann" facial grading systems to assess voluntary movement and synkinesis after facial nerve paralysis [J].
Coulson, SE ;
Croxson, GR ;
Adams, RD ;
O'Dwyer, NJ .
OTOLARYNGOLOGY-HEAD AND NECK SURGERY, 2005, 132 (04) :543-549
[10]   Puckering and blowing facial expressions in people with facial movement disorders [J].
Denlinger, Rachel L. ;
VanSwearingen, Jessie M. ;
Cohn, Jeffrey F. ;
Schmidt, Karen L. .
PHYSICAL THERAPY, 2008, 88 (08) :909-915