Usefulness of intracranial pressure continuous monitoring in pseudotumor cerebri

被引:7
作者
Horcajadas Almansa, Angel [1 ]
Cordero Tous, Nicolas [1 ]
Roman Cutillas, Ana [1 ]
Saura Rojas, Enrique [1 ]
Jorques Infante, Ana [1 ]
Ianez Velasco, Benjamin [1 ]
Sanchez Corral, Carlos [1 ]
机构
[1] Hosp Virgen de las Nieves, Serv Neurocirugia, Granada, Spain
来源
NEUROCIRUGIA | 2015年 / 26卷 / 04期
关键词
Intracranial pressure monitoring; Benign chronic intracranial hypertension; Pseudotumor cerebri; B waves; NeuroPICture; LUMBOPERITONEAL SHUNTS; CLINICAL-PRACTICE; HYDROCEPHALUS; COMPLICATIONS; HYPERTENSION; EXPERIENCE; MANAGEMENT; HEADACHE; DEVICE;
D O I
10.1016/j.neucir.2014.11.010
中图分类号
Q189 [神经科学];
学科分类号
071006 ;
摘要
Objectives: To analyse the usefulness of intracranial pressure (ICP) monitoring in pseudotumor cerebri (PTC). Material and methods: Ten patients with suspected PTC, but having incomplete criteria for the syndrome, on whom ICP monitoring was performed. Demographic, clinical and radiological data were collected, as well as ICP monitoring data and related complications. Results were evaluated 6 months after surgery. Results: In relation to demographics, all patients were young females. Mean ICP was less than 250 mmH(2)O in 5 of 8 patients with pathological monitoring. Most patients (62.5%) showed A waves; these were related with higher mean ICP, but not always with papilloedema. All recordings showed high amplitude B waves. Most pathological recordings showed wave amplitudes superior to 5 mmHg. There were no complications related to the monitoring technique. Conclusions: Clinical and lumbar opening pressure data are not enough to establish PTC diagnosis correctly, especially if patient has been treated previously. Monitoring using ICP is a valuable, safe tool, and very useful in this syndrome. Mean ICP could be normal even with pathological recordings. Morphological analysis is necessary to establish diagnosis. A and B waves are highly related to shunt response. Wave amplitude is related to brain compliance and to shunt response as well. (C) 2013 Sociedad Espanola de Neurocirugia. Published by Elsevier Espana, S.L.U. All rights reserved.
引用
收藏
页码:157 / 166
页数:10
相关论文
共 24 条
[1]  
Czosnyka Marek, 2007, Neurosurg Focus, V22, pE2
[2]   RECORDING OF INTRACRANIAL-PRESSURE AND DAILY DRAINAGE IN PSEUDOTUMOR CEREBRI - A PRELIMINARY-STUDY [J].
DILAURO, L ;
TRAPELLI, F ;
POLI, R ;
ARDIGO, M ;
MARINI, G .
SURGICAL NEUROLOGY, 1984, 22 (02) :178-180
[3]   Is intracranial pressure waveform analysis useful in the management of pediatric neurosurgical patients? [J].
Eide, P. K. ;
Egge, A. ;
Due-Tonnessen, B. J. ;
Helseth, E. .
PEDIATRIC NEUROSURGERY, 2007, 43 (06) :472-481
[4]   Assessment of quality of continuous intracranial pressure recordings in children [J].
Eide, PK .
PEDIATRIC NEUROSURGERY, 2006, 42 (01) :28-34
[5]   Intracranial pressure parameters in idiopathic normal pressure hydrocephalus patients treated with ventriculo-peritoneal shunts [J].
Eide P.K. .
Acta Neurochirurgica, 2006, 148 (1) :21-29
[6]  
Eizaguirre I, 1982, An Esp Pediatr, V16, P520
[7]   The Camino intracranial pressure device in clinical practice.: Assessment in a 1000 cases [J].
Gelabert-González, M ;
Ginesta-Galan, V ;
Sernamito-García, R ;
Allut, AG ;
Bandin-Diéguez, J ;
Rumbo, RM .
ACTA NEUROCHIRURGICA, 2006, 148 (04) :435-441
[8]   LONG-TERM INTRACRANIAL-PRESSURE RECORDING IN MANAGEMENT OF PSEUDOTUMOR CEREBRI [J].
GUCER, G ;
VIERNSTEIN, L .
JOURNAL OF NEUROSURGERY, 1978, 49 (02) :256-263
[9]   Lumboperitoneal shunts: are the complications acceptable? [J].
Karabatsou, K ;
Quigley, G ;
Buxton, N ;
Foy, P ;
Mallucci, C .
ACTA NEUROCHIRURGICA, 2004, 146 (11) :1193-1197
[10]   MONITORING OF INTRACRANIAL PRESSURE [J].
LUNDBERG, N .
PROCEEDINGS OF THE ROYAL SOCIETY OF MEDICINE-LONDON, 1972, 65 (01) :19-&