Experimental characterization of anthracite combustion and NOx emission for a 300-MWe down-fired boiler with a novel combustion system: Influence of primary and vent air distributions

被引:49
作者
Wang, Qingxiang [1 ]
Chen, Zhichao [1 ]
Han, Hui [1 ]
Zeng, Lingyan [1 ]
Li, Zhengqi [1 ]
机构
[1] Harbin Inst Technol, Sch Energy Sci & Engn, 92 West Dazshi St, Harbin 150001, Heilongjiang, Peoples R China
关键词
Down-fired boiler; Swirl burner; Novel combustion technology; Air distribution; Pulverized coal burnout; NOx emission; MOMENTUM FLUX RATIO; UTILITY BOILER; SECONDARY-AIR; COAL COMBUSTION; MULTIPLE-INJECTION; TECHNOLOGY; LOCATION; BURNOUT; TEMPERATURE; REDUCTION;
D O I
10.1016/j.apenergy.2019.01.080
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
To further reduce unburned combustible in fly ash of the improved down-fired boiler with the eccentric-swirl secondary -air combustion technology, a breakthrough idea is proposed to significantly increase the primary air velocity by reducing the damper opening of vent air. In this study, the effects of the high primary air velocity on anthracite burnout and NOx formation are investigated via industrial experiments. With increasing primary air velocity, there is a significant change in the dominant role between the inhibition effect of pulverized coal concentration reduction and the promotion effect of the recirculation zone enlargement on the pulverized coal ignition. With increasing primary air velocity from 23.9 to 32.6 m/s, the flue gas temperature in the furnace hopper increases by approximately 75 degrees C. Besides, the increase of coal char burnout rate at the initial combustion stage is larger than that at the intense combustion stage, and the sum of NOx reduction rates at the initial and intense combustion stages varies from 57 to 61%. The boiler thermal efficiency basically rises linearly from 91 to 92.34% with increasing primary air velocity from 23.9 to 32.6 m/s, and the change of primary air velocity has little influence on the NOx emission at the furnace outlet. Compared with the original boiler, unburned combustible in fly ash decreases by approximately four percentage points, boiler thermal efficiency increases by 3.3%, and NOx emission decreases by 43.3% under the primary air velocity of 32.6 m/s for the improved boiler.
引用
收藏
页码:1551 / 1562
页数:12
相关论文
共 50 条
[21]   Influence of Inner Secondary Air Vane Angle on Combustion Characteristics and NOx Emissions of a Down-Fired Pulverized-Coal 300 MWe Utility Boiler [J].
Fan, Subo ;
Li, Zhengqi ;
Zhu, Qunyi .
COMBUSTION SCIENCE AND TECHNOLOGY, 2013, 185 (06) :975-989
[22]   Combustion and NOx Emission Characteristics of a Down-Fired Furnace with the Hot Air Packing Combustion Technology [J].
Yang, Weijuan ;
Zhou, Zhijun ;
Yang, Wenchuang ;
Zhou, Junhu ;
Wang, Zhihua ;
Liu, Jianzhong ;
Cen, Kefa .
ENERGY & FUELS, 2014, 28 (01) :439-446
[23]   Investigations on combustion optimization and NOX reduction of a 600-MWe down-fired boiler: Influence of rearrangement of tertiary air and jet angle of secondary air and separated over-fire air [J].
Chen, Tao ;
Zhou, Yiding ;
Wang, Ben ;
Deng, Weili ;
Song, Zijian ;
Li, Wei ;
Yang, Wu ;
Sun, Lushi .
JOURNAL OF CLEANER PRODUCTION, 2020, 277
[24]   Reducing NOx Emissions for a 600 MWe Down-Fired Pulverized-Coal Utility Boiler by Applying a Novel Combustion System [J].
Ma, Lun ;
Fang, Qingyan ;
Lv, Dangzhen ;
Zhang, Cheng ;
Chen, Yiping ;
Chen, Gang ;
Duan, Xuenong ;
Wang, Xihuan .
ENVIRONMENTAL SCIENCE & TECHNOLOGY, 2015, 49 (21) :13040-13049
[25]   Combustion stability, burnout and NOx emissions of the 300-MW down-fired boiler with bituminous coal: Load variation and low-load comparison with anthracite [J].
Zhang, Xin ;
Chen, Zhichao ;
Zhang, Mingdi ;
Zeng, Lingyan ;
Li, Zhengqi .
FUEL, 2021, 295
[26]   Influence of outer secondary-air vane angle on combustion characteristics and NOx emissions of a down-fired pulverized-coal 300 MWe utility boiler [J].
Fan, Subo ;
Li, Zhengqi ;
Yang, Xuehai ;
Liu, Guangkui ;
Chen, Zhichao .
FUEL, 2010, 89 (07) :1525-1533
[27]   Characterization of Coal Combustion and Steam Temperature with Respect to Staged-Air Angle in a 600 MWe Down-Fired Boiler [J].
Kuang, Min ;
Li, Zhengqi ;
Ling, Zhongqian ;
Chen, Zhuofu ;
Yuan, Danyan .
ENERGY & FUELS, 2014, 28 (06) :4199-4205
[28]   Industrial-scale Investigations on Combustion Characteristics and NO x Emissions of a 300-MWe Down-fired Boiler: Bituminous Coal Combustion and Coal Varieties Comparison [J].
Zhang, Xin ;
Chen, Zhichao ;
Li, Liankai ;
Zeng, Lingyan ;
Li, Zhengqi .
COMBUSTION SCIENCE AND TECHNOLOGY, 2022, 194 (15) :3155-3174
[29]   Numerical investigation on the influence of nozzle-organization-mode of split burner on flow field distribution and combustion characteristics of a 300-MWe subcritical down-fired boiler [J].
Du, He ;
Zeng, Lingyan ;
Liu, Shuxuan ;
Li, Xiaoguang ;
Yuan, Zhenhua ;
Xie, Cheng ;
Liu, Wenjie ;
Yang, Xiuchao ;
Chen, Zhichao ;
Li, Zhengqi .
ASIA-PACIFIC JOURNAL OF CHEMICAL ENGINEERING, 2019, 14 (06)
[30]   Numerical Simulation of Flow and Combustion Characteristics in a 300 MWe Down-Fired Boiler with Different Overfire Air Angles [J].
Ren, Feng ;
Li, Zhengqi ;
Liu, Guangkui ;
Chen, Zhichao ;
Zhu, Qunyi .
ENERGY & FUELS, 2011, 25 (04) :1457-1464