Increased dose rate precision in combined α and β counting in the μDose system - a probabilistic approach to data analysis

被引:14
|
作者
Tudyka, Konrad [1 ]
Bluszcz, Andrzej [1 ]
Poreba, Grzegorz [1 ]
Milosz, Sebastian [1 ]
Adamiec, Grzegorz [1 ]
Kolarczyk, Aleksander [2 ]
Kolb, Thomas [3 ]
Lomax, Johanna [3 ]
Fuchs, Markus [3 ]
机构
[1] Silesian Tech Univ, Inst Phys, Ctr Sci & Educ, Div Radioisotopes, Ul S Konarskiego 22B, PL-44100 Gliwice, Poland
[2] miDose Solut, Ul Wolnosci 234b-4, PL-41800 Zabrze, Poland
[3] Justus Liebig Univ Giessen, Dept Geog, D-35390 Giessen, Germany
关键词
Monte Carlo; Bayesian; Correlated uncertainties; Luminescence dating; Dose rate; alpha counting; beta counting; AGE; ATTENUATION; SOIL;
D O I
10.1016/j.radmeas.2020.106310
中图分类号
TL [原子能技术]; O571 [原子核物理学];
学科分类号
0827 ; 082701 ;
摘要
The mu Dose system was developed to allow the measurement of environmental levels of natural radioactive isotopes. The system records alpha and beta particles along with four decay pairs arising from successive decays of Bi-214/Po-214, Rn-220/Po-216, Bi-212/Po-212 and Rn-219/Po-215. Under the assumption of secular equilibrium, this allows assessing the specific radioactivities of U-238, U-235, Th-232 day chains and K-40. This assessment provides results with uncertainties which are correlated and, thus, require the development of an error estimation methodology which takes this issue into account. In the current work, we present two different approaches for uncertainty propagation based on Monte Carlo and Bayesian methods. Both approaches produce statistically indistinguishable results and allow significantly better dose rate precision than when the correlations are not accounted for. In the given example, the dose rate precision is improved by a factor of two.
引用
收藏
页数:7
相关论文
共 50 条
  • [1] μDose: A compact system for environmental radioactivity and dose rate measurement
    Tudyka, Konrad
    Milosz, Sebastian
    Adamiec, Grzegorz
    Bluszcz, Andrzej
    Poreba, Grzegorz
    Paszkowski, Lukasz
    Kolarczyk, Aleksander
    RADIATION MEASUREMENTS, 2018, 118 : 8 - 13
  • [2] Shutdown dose rate analysis for the European TBM system in ITER
    Pereslavtsev, P.
    Fischer, U.
    Grosse, D.
    Leichtle, D.
    Majerle, M.
    FUSION ENGINEERING AND DESIGN, 2012, 87 (5-6) : 493 - 497
  • [3] Systematic analysis and modeling of the FLASH sparing effect as a function of dose and dose rate
    Fu, Qi-Bin
    Zhang, Yan
    Wang, Yu-Cheng
    Huang, Tu-Chen
    Zhu, Hong-Yu
    Deng, Xiao-Wu
    NUCLEAR SCIENCE AND TECHNIQUES, 2024, 35 (10)
  • [4] Increased morbidity following the introduction of remote afterloading, with increased dose rate, for cancer of the cervix
    Newman, G
    RADIOTHERAPY AND ONCOLOGY, 1996, 39 (02) : 97 - 103
  • [5] THE INTERNAL DOSE RATE IN QUARTZ GRAINS: EXPERIMENTAL DATA AND CONSEQUENCES FOR LUMINESCENCE DATING
    Szymak, Agnieszka
    Moska, Piotr
    Poreba, Grzegorz
    Tudyka, Konrad
    Adamiec, Grzegorz
    GEOCHRONOMETRIA, 2022, 49 (01): : 9 - 17
  • [6] Using rainfall radar data to improve interpolated maps of dose rate in the Netherlands
    Hiemstra, Paul H.
    Pebesma, Edzer J.
    Heuvelink, Gerard B. M.
    Twenhofel, Chris J. W.
    SCIENCE OF THE TOTAL ENVIRONMENT, 2010, 409 (01) : 123 - 133
  • [7] Assessment of gated sweep technique for total dose and dose rate analysis in bipolar oxides
    Minson, E
    Sanchez, I
    Barnaby, HJ
    Pease, RL
    Platteter, DG
    Dunham, G
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2004, 51 (06) : 3723 - 3729
  • [8] Monte Carlo determination of gamma-ray dose rate with the GEANT system
    Likar, A
    Vidmar, T
    Pucelj, B
    HEALTH PHYSICS, 1998, 75 (02): : 165 - 169
  • [9] Calculation of the Equivalent Dose Rate Distribution Using Data Obtained with a γ Locator
    V. N. Potapov
    A. V. Chesnokov
    S. B. Shcherbak
    Atomic Energy, 2002, 92 : 357 - 366
  • [10] A combined dose calculation and verification method for a small animal precision irradiator based on onboard imaging
    Granton, Patrick V.
    Podesta, Mark
    Landry, Guillaume
    Nijsten, Sebastiaan
    Bootsma, Gregory
    Verhaegen, Frank
    MEDICAL PHYSICS, 2012, 39 (07) : 4155 - 4166