The Utility of Multidetector-Row Computed Tomography Angiography for Evaluating Perforators of Fibular Osteocutaneous Flaps

被引:6
|
作者
Satoh, Takashi [1 ]
Kimata, Yoshihiro [2 ]
Hasegawa, Kenjiro [2 ]
Namba, Yuzaburo [2 ]
机构
[1] Kyorin Univ, Sch Med, Dept Plast & Reconstruct Surg, Tokyo 1818611, Japan
[2] Okayama Univ, Dept Plast Reconstruct Surg, Okayama, Japan
关键词
Fibular osteocutaneous flap; perforator; MDCT angiography; preoperative imaging; PREOPERATIVE LEG ANGIOGRAPHY; ANTEROLATERAL THIGH FLAP; CT ANGIOGRAPHY; RECONSTRUCTION; DOPPLER; NEED;
D O I
10.1055/s-0030-1267380
中图分类号
R61 [外科手术学];
学科分类号
摘要
Multidetector-row computed tomography angiography (MDCTA) can be used to visualize small vessels and has been used to search for perforators in deep inferior epigastric artery perforator flaps and anterolateral thigh flaps. Fibula osteocutaneous flaps are often used for mandibular reconstruction, but questions remain about the reliability of these flaps and the variety of their perforators. Eight patients who were candidates for mandibular or pedal reconstruction with a fibula osteocutaneous flap were prospectively evaluated with MDCTA and Doppler sonography. We evaluated the number, position, and course of perforators with MDCTA. The perforators were classified, and intraoperative findings were compared with those of Doppler sonography and MDCTA. MDCTA accurately identified the perforators and showed a satisfactory concordance with intraoperative findings. The high spatial resolution of MDCTA allows the perforators' origin, course, and type to be precisely described. Eighteen vessels were identified with MDCTA, and on average, 2.3 vessels were identified in the leg of each patient. The rate of concordance with operative findings was 87.5% for MDCTA. With MDCTA, flap perforators can be accurately evaluated before surgery in a manner not possible with traditional angiography or Doppler sonography. Reliable perforators can be chosen, and detailed operative plans can be made.
引用
收藏
页码:29 / 36
页数:8
相关论文
共 50 条
  • [21] Detection of intracranial aneurysms with 64 channel multidetector row computed tomography: Comparison with digital subtraction angiography
    Pozzi-Mucelli, Fabio
    Bruni, Stefano
    Doddi, Marco
    Calgaro, Antonio
    Braini, Massimiliano
    Cova, Maria
    EUROPEAN JOURNAL OF RADIOLOGY, 2007, 64 (01) : 15 - 26
  • [22] Comparison of Multidetector-Row Computed Tomography and Duplex Doppler Ultrasonography in Detecting Atherosclerotic Carotid Plaques Complicated with Intraplaque Hemorrhage
    Ajduk, Marko
    Bulimbasic, Stela
    Pavic, Ladislav
    Sarlija, Mirko
    Patrlj, Leonardo
    Brkljacic, Boris
    Pavic, Predrag
    Cikara, Igor
    Ivanac, Gordana
    COLLEGIUM ANTROPOLOGICUM, 2013, 37 (01) : 213 - 219
  • [23] Optimal iodine dose for 3-dimensional multidetector-row CT angiography of the liver
    Ichikawa, Tomoaki
    Motosugi, Utaroh
    Morisaka, Hiroyuki
    Sou, Hironobu
    Onohara, Kojiro
    Sano, Katsuhiro
    Araki, Tsutomu
    EUROPEAN JOURNAL OF RADIOLOGY, 2012, 81 (09) : 2450 - 2455
  • [24] Assessment of Moyamoya Disease Using Multidetector Row Computed Tomography
    Sugino, Toshiya
    Mikami, Takeshi
    Ohtaki, Shunya
    Hirano, Tohru
    Iihoshi, Satoshi
    Houkin, Kiyohiro
    Mikuni, Nobuhiro
    JOURNAL OF STROKE & CEREBROVASCULAR DISEASES, 2013, 22 (05) : 644 - 649
  • [25] Preoperative Computed Tomography Angiography for ALT Flaps Optimizes Design and Reduces Operative Time
    Schneider, Christopher M.
    Palines, Patrick A.
    Womac, Daniel J.
    Tuggle, Charles T.
    St Hilaire, Hugo
    Stalder, Mark W.
    JOURNAL OF RECONSTRUCTIVE MICROSURGERY, 2022, 38 (06) : 491 - 498
  • [26] Multidetector Row Computed Tomography in the Management of Penetrating Neck Injuries
    Munera, Felipe
    Danton, Gary
    Rivas, Luis A.
    Henry, Robert P.
    Ferrari, Michelle G.
    SEMINARS IN ULTRASOUND CT AND MRI, 2009, 30 (03) : 195 - 204
  • [27] Radiation dose in multidetector row computed tomography cardiac imaging
    Bae, KT
    Hong, C
    Whiting, BR
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2004, 19 (06) : 859 - 863
  • [28] Grading of carotid artery stenosis with multidetector-row CT angiography: visual estimation or caliper measurements?
    Annet Waaijer
    M. Weber
    M. S. van Leeuwen
    J. Kardux
    W. B. Veldhuis
    R. Lo
    F. J. A. Beek
    M. Prokop
    European Radiology, 2009, 19 : 2809 - 2818
  • [29] Grading of carotid artery stenosis with multidetector-row CT angiography: visual estimation or caliper measurements?
    Waaijer, Annet
    Weber, M.
    van Leeuwen, M. S.
    Kardux, J.
    Veldhuis, W. B.
    Lo, R.
    Beek, F. J. A.
    Prokop, M.
    EUROPEAN RADIOLOGY, 2009, 19 (12) : 2809 - 2818
  • [30] Prospective evaluation of multidetector-row CT angiography for the diagnosis of vasospasm following subarachnoid hemorrhage: A comparison with digital subtraction angiography
    Chaudhary, Saadia R.
    Ko, Nerissa
    Dillon, William P.
    Yu, Melissa B.
    Liu, Songling
    Criqui, Geoffrey I.
    Higashida, Randall T.
    Smith, Wade S.
    Wintermark, Max
    CEREBROVASCULAR DISEASES, 2008, 25 (1-2) : 144 - 150