Evaluation of Optical Refractometer for Assessing Failure of Transfer of Passive Immunity in Foals

被引:10
作者
de Sobral, Gilvannya Goncalves [1 ]
Neto, Oswaldo Christiano Gomes [2 ]
da Silva, Avaniel Marinho [3 ]
Carneiro, Gustavo Ferrer [1 ]
机构
[1] Univ Fed Rural Pernambuco, Recife, PE, Brazil
[2] Cent Monte Verde Reprod Equina, Saire, PE, Brazil
[3] HEBRON Farmaceut Caruaru, Caruaru, PE, Brazil
关键词
Total protein; Immunoglobulins; Radial immunodiffusion; IMMUNOGLOBULIN-G CONCENTRATION; RADIAL IMMUNODIFFUSION; IGG CONCENTRATIONS; VALIDATION; DISORDERS; DIAGNOSIS; COLOSTRUM; VALUES; CARE;
D O I
10.1016/j.jevs.2021.103758
中图分类号
S85 [动物医学(兽医学)];
学科分类号
0906 ;
摘要
The aim of the present study is to evaluate the correlation between the total protein measured by an optical refractometer and the concentration of IgG by radial immunodiffusion (RID) to determine the performance of the optical refractometer to diagnose the failure of passive transfer of immunity (FPTI) in 12-hour-old foals. Blood was collected from foals (n = 30) 12 hours after birth. A study was carried out to measure the serum IgG concentration by RID test and measure total protein (TP) by optical refractometer. The correlation coefficient was measured between the TP concentration and the IgG-RID. Correlation was made between the IgG-IDR levels of colostrum in mares and the IgG-IDR concentration of the plasma of the foals. A ROC curve was made to identify the ideal cutoff point, in addition to the tests for sensitivity and specificity. The area under the curve (AUC) was calculated. The IgG concentration by RID was positively correlated with a refractometer. Colostrum IgG concentration by RID was moderately correlated with foal plasma IgG-RID concentration. In the ROC curve, AUC was 0.931, and the cutoff point found was <= 5,7 g/dL as the most optimal combination, with 100% sensitivity and 73.3% specificity. Thus, it can be concluded that the total protein concentration by refractometer shows effective utility in the evaluation of FPTI in foals since they are highly sensitive, associated with a low cost, easy to handle, and easily carried out in the field. (C) 2021 Elsevier Inc. All rights reserved.
引用
收藏
页数:5
相关论文
共 30 条
[1]   Causes of equine perinatal mortality [J].
Abraham, Michelle ;
Bauquier, Jennifer .
VETERINARY JOURNAL, 2021, 273
[2]  
Acworth NRJ, 2003, EQUINE VET EDUC, V15, P207, DOI 10.1111/j.2042-3292.2003.tb00245.x
[3]   Immunodeficiency disorders in horses [J].
Crisman, Mark V. ;
Scarratt, W. Kent .
VETERINARY CLINICS OF NORTH AMERICA-EQUINE PRACTICE, 2008, 24 (02) :299-+
[4]  
Santos Fernanda Carlini Cunha, 2014, Ciênc. anim. bras., V15, P307, DOI 10.1590/1809-6891v15i323935
[5]  
Curcio BR, 2012, ANIM REPROD, V9, P182
[6]   Evaluation of five commercially available assays and measurement of serum total protein concentration via refractometry for the diagnosis of failure of passive transfer of immunity in foals [J].
Davis, R ;
Giguère, S .
JAVMA-JOURNAL OF THE AMERICAN VETERINARY MEDICAL ASSOCIATION, 2005, 227 (10) :1640-1645
[7]   Comparison of tests for failure of passive transfer in neonatal calf serum using total protein refractometry and the biuret method [J].
Denholm, Katharine ;
Haggerty, Alexandra ;
Mason, Colin ;
Ellis, Kathryn .
PREVENTIVE VETERINARY MEDICINE, 2021, 189
[8]   Pathophysiology, diagnosis and treatment of neonatal sepsis [J].
Dunkel, B. ;
Corley, K. T. T. .
EQUINE VETERINARY EDUCATION, 2015, 27 (02) :92-98
[9]   Usefulness of digital and optical refractometers for the diagnosis of failure of transfer of passive immunity in neonatal foals [J].
Elsohaby, I. ;
Riley, C. B. ;
McClure, J. T. .
EQUINE VETERINARY JOURNAL, 2019, 51 (04) :451-457
[10]   Evaluation of Digital and Optical Refractometers for Assessing Failure of Transfer of Passive Immunity in Dairy Calves [J].
Elsohaby, I. ;
McClure, J. T. ;
Keefe, G. P. .