Automatic Method for Bone Segmentation in Cone Beam Computed Tomography Data Set

被引:10
作者
Vaitiekunas, Mantas [1 ]
Jegelevicius, Darius [1 ,2 ]
Sakalauskas, Andrius [3 ]
Grybauskas, Simonas [4 ]
机构
[1] Kaunas Univ Technol, Biomed Engn Inst, LT-51423 Kaunas, Lithuania
[2] Kaunas Univ Technol, Dept Elect Engn, LT-51367 Kaunas, Lithuania
[3] JSC Telemed, LT-03154 Vilnius, Lithuania
[4] Simonas Grybauskas Orthognath Surg, LT-03229 Vilnius, Lithuania
来源
APPLIED SCIENCES-BASEL | 2020年 / 10卷 / 01期
关键词
cone beam computed tomography; automatic segmentation; sliding window; 3D virtual surgical plan; Otsu's method; MAGNETIC-RESONANCE IMAGES; CT; MODEL;
D O I
10.3390/app10010236
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
Due to technical aspects of Cone Beam Computed Tomography (CBCT), the automatic methods for bone segmentation are not widely used in the clinical practice of endodontics, orthodontics, oral and maxillofacial surgery. The aim of this study was to evaluate method's accuracy for bone segmentation in CBCT data sets. The sliding three dimensional (3D) window, histogram filter and Otsu's method were used to implement the automatic segmentation. The results of automatic segmentation were compared with the results of segmentation performed by an experienced oral and maxillofacial surgeon. Twenty patients and their forty CBCT data sets were used in this study (20 preoperative and 20 postoperative). Intraclass Correlation Coefficients (ICC) were calculated to prove the reliability of surgeon segmentations. ICC was 0.958 with 95% confidence interval [0.896 ... 0.983] in preoperative data sets and 0.931 with 95% confidence interval [0.836 ... 0.972] in postoperative data sets. Three basic metrics were used in order to evaluate the accuracy of the automatic method-Dice Similarity Coefficient (DSC), Root Mean Square (RMS), Average Distance Error (ADE) of surfaces mismatch and additional metric in order to evaluate computation time of segmentation was used. The mean value of preoperative DSC was 0.921, postoperative-0.911, the mean value of preoperative RMS was 0.559 mm, postoperative-0.647 mm, the ADE value of preoperative cases was 0.043 mm, postoperative-0.057 mm, the mean computational time to perform the segmentation was 46 s. The automatic method showed clinically acceptable accuracy results and thus can be used as a new tool for automatic bone segmentation in CBCT data. It can be applied in oral and maxillofacial surgery for performance of 3D Virtual Surgical Plan (VSP) or for postoperative follow-up.
引用
收藏
页数:13
相关论文
共 50 条
  • [31] Innovative Tool for Automatic Detection of Arterial Stenosis on Cone Beam Computed Tomography
    Simoni, Agnese
    Barcali, Eleonora
    Lorenzetto, Cosimo
    Tiribilli, Eleonora
    Rastrelli, Vieri
    Manetti, Leonardo
    Nardi, Cosimo
    Iadanza, Ernesto
    Bocchi, Leonardo
    APPLIED SCIENCES-BASEL, 2023, 13 (02):
  • [32] Automatic Classification System for Periapical Lesions in Cone-Beam Computed Tomography
    Andrade Calazans, Maria Alice
    Ferreira, Felipe Alberto B. S.
    Melo Guedes Alcoforado, Maria de Lourdes
    dos Santos, Andrezza
    Pontual, Andrea dos Anjos
    Madeiro, Francisco
    SENSORS, 2022, 22 (17)
  • [33] Panoramic cone beam computed tomography
    Chang, Jenghwa
    Zhou, Lili
    Wang, Song
    Chao, K. S. Clifford
    MEDICAL PHYSICS, 2012, 39 (05) : 2930 - 2946
  • [34] Cone Beam Computed Tomography in Orthodontics
    Dindaroglu, Furkan
    Yetkiner, Enver
    TURKISH JOURNAL OF ORTHODONTICS, 2016, 29 (01) : 16 - 21
  • [35] Cone Beam Computed Tomography in Orthodontics
    Coskun, Ipek
    Kaya, Burcak
    TURKISH JOURNAL OF ORTHODONTICS, 2018, 31 (02) : 55 - 61
  • [36] A Laboratory Scanner for Cone Beam Breast Computed Tomography
    Russo, P.
    Mettivier, G.
    Lauria, A.
    Montesi, M. C.
    WORLD CONGRESS ON MEDICAL PHYSICS AND BIOMEDICAL ENGINEERING, VOL 25, PT 2 - DIAGNOSTIC IMAGING, 2009, 25 : 563 - 565
  • [37] Use of cone beam computed tomography in otolaryngologic treatments
    Cakli, Hamdi
    Cingi, Cemal
    Ay, Yazgi
    Oghan, Fatih
    Ozer, Torun
    Kaya, Ercan
    EUROPEAN ARCHIVES OF OTO-RHINO-LARYNGOLOGY, 2012, 269 (03) : 711 - 720
  • [38] Operational principles for cone-beam computed tomography
    Hatcher, David C.
    JOURNAL OF THE AMERICAN DENTAL ASSOCIATION, 2010, 141 (10) : 3S - 6S
  • [39] Radiation Exposure of Abdominal Cone Beam Computed Tomography
    Sailer, Anna M.
    Schurink, Geert Willem H.
    Wildberger, Joachim E.
    de Graaf, Rick
    van Zwam, Willem H.
    de Haan, Michiel W.
    Kemerink, Gerrit J.
    Jeukens, Cecile R. L. P. N.
    CARDIOVASCULAR AND INTERVENTIONAL RADIOLOGY, 2015, 38 (01) : 112 - 120
  • [40] Cone Beam Computed Tomography and Virtual Cloning: A Review
    Sarkar, Anand Shankar
    Hegde, Shruthi
    Ajila, Vidya
    Darwin, Deepthi
    JOURNAL OF HEALTH AND ALLIED SCIENCES NU, 2024, 14 (01): : 17 - 22