Accuracy of iodine quantification using dual energy CT in latest generation dual source and dual layer CT

被引:166
|
作者
Pelgrim, Gert Jan [1 ]
van Hamersvelt, Robbert W. [2 ]
Willemink, Martin J. [2 ]
Schmidt, Bernhard T. [3 ]
Flohr, Thomas [3 ]
Schilham, Arnold [2 ]
Milles, Julien [4 ]
Oudkerk, Matthijs [1 ]
Leiner, Tim [2 ]
Vliegenthart, Rozemarijn [1 ,5 ]
机构
[1] Univ Groningen, Univ Med Ctr Groningen, Ctr Med Imaging North East Netherlands, POB EB44,Hanzepl 1, NL-9713 GZ Groningen, Netherlands
[2] Univ Utrecht, Med Ctr, Dept Radiol, Utrecht, Netherlands
[3] Siemens Healthcare GmbH, Forchheim, Germany
[4] Philips Healthcare, Best, Netherlands
[5] Univ Groningen, Univ Med Ctr Groningen, Dept Radiol, Groningen, Netherlands
关键词
Tomography; x-ray computed; Absorptiometry; photon; Myocardial perfusion imaging; Iodine; Phantoms; imaging; COMPUTED-TOMOGRAPHY; IMAGE-QUALITY; PHANTOM;
D O I
10.1007/s00330-017-4752-9
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
To determine the accuracy of iodine quantification with dual energy computed tomography (DECT) in two high-end CT systems with different spectral imaging techniques. Five tubes with different iodine concentrations (0, 5, 10, 15, 20 mg/ml) were analysed in an anthropomorphic thoracic phantom. Adding two phantom rings simulated increased patient size. For third-generation dual source CT (DSCT), tube voltage combinations of 150Sn and 70, 80, 90, 100 kVp were analysed. For dual layer CT (DLCT), 120 and 140 kVp were used. Scans were repeated three times. Median normalized values and interquartile ranges (IQRs) were calculated for all kVp settings and phantom sizes. Correlation between measured and known iodine concentrations was excellent for both systems (R = 0.999-1.000, p < 0.0001). For DSCT, median measurement errors ranged from -0.5% (IQR -2.0, 2.0%) at 150Sn/70 kVp and -2.3% (IQR -4.0, -0.1%) at 150Sn/80 kVp to -4.0% (IQR -6.0, -2.8%) at 150Sn/90 kVp. For DLCT, median measurement errors ranged from -3.3% (IQR -4.9, -1.5%) at 140 kVp to -4.6% (IQR -6.0, -3.6%) at 120 kVp. Larger phantom sizes increased variability of iodine measurements (p < 0.05). Iodine concentration can be accurately quantified with state-of-the-art DECT systems from two vendors. The lowest absolute errors were found for DSCT using the 150Sn/70 kVp or 150Sn/80 kVp combinations, which was slightly more accurate than 140 kVp in DLCT.
引用
收藏
页码:3904 / 3912
页数:9
相关论文
共 50 条
  • [1] Accuracy of iodine quantification using dual energy CT in latest generation dual source and dual layer CT
    Gert Jan Pelgrim
    Robbert W. van Hamersvelt
    Martin J. Willemink
    Bernhard T. Schmidt
    Thomas Flohr
    Arnold Schilham
    Julien Milles
    Matthijs Oudkerk
    Tim Leiner
    Rozemarijn Vliegenthart
    European Radiology, 2017, 27 : 3904 - 3912
  • [2] Accuracy of iodine quantification in dual energy CT: A phantom study across 3 different CT systems
    Dehlinger, N.
    Bach, J.
    Willaume, T.
    Ohana, M.
    Dillenseger, J. P.
    RADIOGRAPHY, 2024, 30 (01) : 226 - 230
  • [4] Cerebral artery evaluation of dual energy CT angiography with dual source CT
    Ma Rui
    Liu Cheng
    Deng Kai
    Song Shao-juan
    Wang Dao-ping
    Huang Ling
    CHINESE MEDICAL JOURNAL, 2010, 123 (09) : 1139 - 1144
  • [5] Dual-Energy CT: Lower Limits of Iodine Detection and Quantification
    Jacobsen, Megan C.
    Cressman, Erik N. K.
    Tamm, Eric P.
    Baluya, Dodge L.
    Duan, Xinhui
    Cody, Dianna D.
    Schellingerhout, Dawid
    Layman, Rick R.
    RADIOLOGY, 2019, 292 (02) : 414 - 419
  • [6] Iodine Beam Hardening Correction for Single KVp CT and Quantification Accuracy Relative to Dual-Energy Monochromatic CT
    Yadava, G.
    Imai, Y.
    Hsieh, J.
    MEDICAL PHYSICS, 2014, 41 (06) : 452 - 452
  • [7] Gastrointestinal Applications of Iodine Quantification Using Dual-Energy CT: A Systematic Review
    Xu, Jack Junchi
    Taudorf, Mikkel
    Ulriksen, Peter Sommer
    Achiam, Michael Patrick
    Resch, Timothy Andrew
    Nielsen, Michael Bachmann
    Lonn, Lars Birger
    Hansen, Kristoffer Lindskov
    DIAGNOSTICS, 2020, 10 (10)
  • [8] Dual-Energy CT Iodine Accuracy Across Vendors and Platforms
    Jacobsen, M.
    Wood, C.
    Cody, D.
    MEDICAL PHYSICS, 2016, 43 (06) : 3835 - 3836
  • [9] Implementation of a Dual Source Dual Energy CT for Proton Therapy
    Cheng, C.
    O'Reilly, S.
    Malajovich, I.
    Lalonde, A.
    Burgdorf, B.
    Zou, J.
    Yin, L.
    Swisher-McClure, S.
    Ghiam, A. Fotouhi
    Lukens, J.
    Lin, A.
    Dong, L.
    Teo, B. K.
    MEDICAL PHYSICS, 2019, 46 (06) : E120 - E121
  • [10] Evaluation of Intra-Manufacturer Dual-Energy CT Iodine Quantification Accuracy: Phantom Studies
    Zhao, A.
    Borhani, A.
    Catania, R.
    MEDICAL PHYSICS, 2021, 48 (06)