Intraoperative digital radiography for diagnosis of non-palpable breast lesions

被引:10
作者
Diekmann, F
Grebe, S
Bick, U
Winzer, KJ
Paepke, S
Hamm, B
机构
[1] Humboldt Univ, Charite, Inst Radiol, D-10117 Berlin, Germany
[2] Univ Chicago, Dept Radiol, Chicago, IL 60637 USA
[3] Humboldt Univ, Charite, Klin Allgemein Viszeral Gefass & Thoraxchirurg, Berlin, Germany
[4] Humboldt Univ, Charite, Abt Frauenheilkunde & Geburtshilfe, Berlin, Germany
来源
ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN | 2000年 / 172卷 / 12期
关键词
specimen radiography; digital; mammography;
D O I
10.1055/s-2000-9211
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: A procedure for performing intraoperative digital radiography of diagnostic breast specimens directly in the operating suite with teleradiologic assessment by a radiologist is presented. The efficiency of this procedure is compared with that of conventional magnification mammography performed in the radiology department. Material and Methods: Thirty-six specimen radiographs obtained by conventional magnification mammography were compared with 38 intraoperative digital magnification radiographs (DIMA Soft P42 prototype, Feinfocus Inc., Garbsen). The radiographs were assessed for lesion conspicuity and time savings for the surgeon, anesthesiologist, and radiologist. Results: The new procedure identified all 38 labeled pathological lesions, and the conventional technique likewise had a detection rate of 100% (36/36). The new technique resulted in considerable time savings for the surgeon and the radiologist. The duration of surgery was shorter and the time interval from removal of the specimen to reporting of the results was reduced from about 23 min to about 13 min. A single radiograph was sufficient for complete visualization of the specimen in all cases. Conclusion: Digital intraoperative specimen radiography considerably reduces the time of surgery depending on the local conditions and is highly accurate in locating a suspicious area within the tissue.
引用
收藏
页码:969 / 971
页数:3
相关论文
共 8 条
  • [1] Predictive value of specimen radiography for core needle biopsy of noncalcified breast masses
    Berg, WA
    Jaeger, B
    Campassi, C
    Kumar, D
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 1998, 171 (06) : 1671 - 1678
  • [2] MANAGEMENT OF THE BREAST SPECIMEN
    DORSI, CJ
    [J]. RADIOLOGY, 1995, 194 (02) : 297 - 302
  • [3] GALLAGER HS, 1975, AM J CLIN PATHOL, V646, P749
  • [4] Magnified radiographs as quality control for detection of microcalcifications in histopathology of breast biopsies
    Grunert, JH
    Flemming, P
    Borchert, B
    Farber, A
    Gmelin, E
    [J]. ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN, 2000, 172 (01): : 68 - 72
  • [5] Detection of micro calcifications in breast specimen by 4-fold DIMA direct magnification radiography compared to 1.5-fold conventional magnification radiography.
    Grunert, JH
    Borchert, B
    Farber, A
    Gmelin, E
    [J]. ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN, 1999, 171 (04): : 302 - 306
  • [6] Grunert JH, 1999, ROFO-FORTSCHR RONTG, V170, P347
  • [7] A new specimen radiography system with maximal 20fold magnification for breast specimens
    Moritz, JD
    Westerhof, JP
    Funke, M
    Breiter, N
    Oestmann, JW
    Grabbe, E
    [J]. ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN, 1998, 168 (02): : 133 - 138
  • [8] EFFICACY OF SPECIMEN RADIOGRAPHY OF CLINICALLY OCCULT NONCALCIFIED BREAST-LESIONS
    STOMPER, PC
    DAVIS, SP
    SONNENFELD, MR
    MEYER, JE
    GREENES, RA
    EBERLEIN, TJ
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 1988, 151 (01) : 43 - 47