A Histogram-Difference Method for Neutron/Gamma Discrimination Using Liquid and Plastic Scintillators

被引:9
作者
French, Robert M. [1 ]
Thevenin, Mathieu [2 ]
Hamel, Matthieu [2 ]
Montbarbon, Eva [2 ]
机构
[1] Univ Bourgogne, French Natl Ctr Sci Res, F-21000 Dijon, France
[2] CEA, LIST, French Atom Energy Commiss, F-91191 Gif Sur Yvette, France
关键词
Neutron-gamma discrimination; plastic scintillators; Qtail; Qtotal; PULSE-SHAPE DISCRIMINATION; GAMMA DISCRIMINATION; PERFORMANCE; DETECTORS; CF-252;
D O I
10.1109/TNS.2017.2720798
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
This paper introduces a novel and extremely simple-and therefore, easily implemented in a fieldprogrammable gate array-method of neutron/gamma pulse discrimination called the histogram-difference method (HDM). Crucially, this method relies on the use of a "reference set" of gamma-only pulses from Na-22, Cs-137, and Co-60 sources and on features extracted from the pulses. The pulses from this reference set are compared to a set of an identical number of n+gamma pulses from a Cf-252 source. Not only can HDM determine the presence of neutrons in the 252Cf source, but it can also estimate the approximate percentage of neutron pulses from that source. The results reported in this paper are based on data from different radioactive sources and a standard scintillator for this type of research, namely, BC-501A. These results were confirmed using three other scintillators, one made in-house and two others that are commercially available, EJ-299-33 and EJ-200. Pulses were encoded using Q values, which are features extracted from the pulses, that is, (Q(total), Q(tail)) pairs in SR2. As control, we also encoded pulses as the root-mean-square (RMS) distances from the average pulse of all known. -only pulses and ran HDM using these pulse representations. The results are very similar to those obtained using a Q-value encoding of the pulses.
引用
收藏
页码:2423 / 2432
页数:10
相关论文
共 25 条
  • [11] Neutron-gamma discrimination in plastic scintillators
    Hansen, RR
    Reeder, PL
    Peurrung, AJ
    Stromswold, DC
    [J]. IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2000, 47 (06) : 2024 - 2028
  • [12] Digital pulse-shape algorithms for scintillation-based neutron detectors
    Jastaniah, SD
    Sellin, PJ
    [J]. IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2002, 49 (04) : 1824 - 1828
  • [13] EJ-309 pulse shape discrimination performance with a high gamma-ray-to-neutron ratio and low threshold
    Kaplan, A. C.
    Flaska, M.
    Enqvist, A.
    Dolan, J. L.
    Pozzi, S. A.
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2013, 729 : 463 - 468
  • [14] Lawrence CC, 2010, IEEE NUCL SCI CONF R, P110, DOI 10.1109/NSSMIC.2010.5873726
  • [15] Test of digital neutron-gamma discrimination with four different photomultiplier tubes for the NEutron Detector Array (NEDA)
    Luo, X. L.
    Modamio, V.
    Nyberg, J.
    Valiente-Dobon, J. J.
    Nishada, Q.
    de Angelis, G.
    Agramunt, J.
    Egea, F. J.
    Erduran, M. N.
    Erturk, S.
    de France, G.
    Gadea, A.
    Gonzalez, V.
    Hueyuek, T.
    Jaworski, G.
    Moszynski, M.
    Di Nitto, A.
    Palacz, M.
    Soederstroem, P. -A.
    Sanchis, E.
    Triossi, A.
    Wadsworth, R.
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2014, 767 : 83 - 91
  • [16] STUDY OF N-GAMMA DISCRIMINATION WITH NE213 AND BC501A LIQUID SCINTILLATORS OF DIFFERENT SIZE
    MOSZYNSKI, M
    COSTA, GJ
    GUILLAUME, G
    HEUSCH, B
    HUCK, A
    MOUATASSIM, S
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1994, 350 (1-2) : 226 - 234
  • [17] Normand S., 2011, P ANIMMA, P1
  • [18] Okamoto K., 1980, P IAEA CONS MEET NEU, P90
  • [19] Testing on novel neutron detectors as alternative to 3He for security applications
    Peerani, Paolo
    Tomanin, Alice
    Pozzi, Sara
    Dolan, Jennifer
    Miller, Eric
    Flaska, Marek
    Battaglieri, Marco
    De Vita, Raffaella
    Ficini, Luisa
    Ottonello, Giacomo
    Ricco, Giovanni
    Dermody, Geraint
    Giles, Calvin
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2012, 696 : 110 - 120
  • [20] Study of the thermal neutron detector ZnS(Ag)/LiF response using digital pulse processing
    Pino, F.
    Stevanato, L.
    Cester, D.
    Nebbia, G.
    Sajo-Bohus, L.
    Viesti, G.
    [J]. JOURNAL OF INSTRUMENTATION, 2015, 10