Tests on high-strength rectangular concrete-filled steel hollow section stub columns

被引:133
作者
Liu, DL [1 ]
机构
[1] Nanyang Technol Univ, Sch Civil & Environm Engn, Singapore 639798, Singapore
关键词
column; concentric loading; concrete; high strength; steel;
D O I
10.1016/j.jcsr.2005.01.001
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
An experimental programme on high-strength rectangular concrete-filled steel hollow section columns is reported. A total of 22 specimens were tested under concentric loading. The test variables include the material strengths (f(y) = 495 MPa; f(c)' = 60 and 89 MPa), cross-sectional aspect ratio (1.0-2.0) and volumetric steel-to-concrete ratio (0.13-0.17). Favourable ductility performance was observed for the specimens in the tests. The experimental results are employed to calibrate the specifications in the codes (EC4, ACI and AISC) for the design of high-strength composite columns. Comparison indicates that the specifications in ACI and AISC conservatively estimate the failure loads of the specimens by 9 and 11%, respectively. The EC4 method gives a close and conservative estimate of the ultimate capacities with a difference of M (c) 2005 Elsevier Ltd. All rights reserved.
引用
收藏
页码:902 / 911
页数:10
相关论文
共 16 条
[1]  
*AM CONCR I, 2002, ACI31802ACI 318R02
[2]  
*AM SOC TEST MAT, 1997, TEST METH TENS TEST
[3]  
[Anonymous], 1999, LOAD RES FACT DES SP
[4]  
*BRIT STAND I, 1994, 199411 ENV
[5]   Behavior of eccentrically loaded concrete-filled steel tubular columns [J].
Fujimoto, T ;
Mukai, A ;
Nishiyama, I ;
Sakino, K .
JOURNAL OF STRUCTURAL ENGINEERING, 2004, 130 (02) :203-212
[6]   STRENGTH ANALYSIS OF CONCRETE-FILLED THIN-WALLED STEEL BOX COLUMNS [J].
GE, HB ;
USAMI, T .
JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 1994, 30 (03) :259-281
[7]   Flexural behaviour of high-strength rectangular concrete-filled steel hollow sections [J].
Gho, WM ;
Liu, DL .
JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 2004, 60 (11) :1681-1696
[8]   Tests on stub columns of concrete-filled RHS sections [J].
Han, LH .
JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 2002, 58 (03) :353-372
[9]  
Kilpatrick AE, 1999, ACI STRUCT J, V96, P642
[10]   Ultimate capacity of high-strength rectangular concrete-filled steel hollow section stub columns [J].
Liu, DL ;
Gho, WM ;
Yuan, H .
JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 2003, 59 (12) :1499-1515