Clinical Walking Tests and Gait Pattern Characterization During 6-Minute Walk Test Using Inertial Sensors: Follow-Up in Individuals With Lower Limb Amputation

被引:0
|
作者
Younesian, Hananeh [1 ,2 ]
Legrand, Thomas [1 ,2 ]
Miramand, Ludovic [1 ,2 ]
Beausoleil, Sarah [1 ,2 ]
Turcot, Katia [1 ,2 ]
机构
[1] Laval Univ, Dept Kinesiol, Quebec City, PQ, Canada
[2] Ctr Interdisciplinary Res Rehabil & Social Integr, Quebec City, PQ, Canada
关键词
cadence; stance ratio; push-up ratio; variability; amputees; GO TEST; BALANCE; PEOPLE; MOBILITY; PERFORMANCE; IMPROVEMENT; CAPACITY; AMPUTEES; VALUES; SPEED;
D O I
10.1123/jab.2020-0327
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Inertial measurement units and normative values enable clinicians to quantify clinical walking tests and set rehabilitation goals. Objectives of this study were (1) to compare time- and distance-based walking tests in individuals with lower limb amputation (iLLA) and normative values following rehabilitation discharge (T1) and 6 weeks after discharge (T2) and (2) to investigate spatiotemporal and foot kinematic parameters over a 6-minute walk test using inertial measurement units. Twelve iLLA participated in this study. Distance, cadence, stance ratio, loading rate ratio, push-up ratio, path length, and minimum toe clearance were analyzed during 6-minute walk test. Nonparametric repeated-measures analysis of variance tests, Bonferroni corrections, were performed. Time of distance-based walking tests diminished at T2 (P < .02). Compared with normative values, walking performance in iLLA was reduced. Cadence at T2 increased significantly (P = .026). Stance ratio increased in both legs at T2 (P < .05). Push-up ratio tended to decrease at T2 in the amputated leg (P= .0003). Variability of path length and minimum toe clearance at T2 were less than at 11 in the nonamputated leg (P < .05). Spatiotemporal improvement at T2 could be due to prosthesis adaptation in iLLA. The lower performance of the functional walk test compared with normative values could be due to amputation and pain-related fatigue.
引用
收藏
页码:440 / 449
页数:10
相关论文
共 5 条
  • [1] Evolution of gait parameters in individuals with a lower-limb amputation during a six-minute walk test
    Beausoleil, Sarah
    Miramand, Ludovic
    Turcot, Katia
    GAIT & POSTURE, 2019, 72 : 40 - 45
  • [2] Wearable Inertial Sensors to Assess Gait during the 6-Minute Walk Test: A Systematic Review
    Storm, Fabio Alexander
    Cesareo, Ambra
    Reni, Gianluigi
    Biffi, Emilia
    SENSORS, 2020, 20 (09)
  • [3] Minimal clinically important difference in walking velocity, gait profile score and two minute walk test for individuals with lower limb amputation
    Carse, Bruce
    Scott, Helen
    Davie-Smith, Fiona
    Brady, Laura
    Colvin, John
    GAIT & POSTURE, 2021, 88 : 221 - 224
  • [4] The use of the 6-min walk test as a proxy for the assessment of energy expenditure during gait in individuals with lower-limb amputation
    Kark, Lauren
    McIntosh, Andrew S.
    Simmons, Anne
    INTERNATIONAL JOURNAL OF REHABILITATION RESEARCH, 2011, 34 (03) : 227 - 234
  • [5] Gait parameters assessed with inertial measurement unit during 6-minute walk test in people after stroke
    Pollet, Joel
    Buraschi, Riccardo
    Villafane, Jorge Hugo
    Piovanelli, Barbara
    Negrini, Stefano
    INTERNATIONAL JOURNAL OF REHABILITATION RESEARCH, 2021, 44 (04) : 358 - 363