Determination of octylphenol and nonylphenol in aqueous sample using simultaneous derivatization and dispersive liquid-liquid microextraction followed by gas chromatography-mass spectrometry

被引:69
作者
Luo, Shusheng [1 ]
Fang, Ling [1 ]
Wang, Xiaowei [1 ]
Liu, Hongtao [2 ]
Ouyang, Gangfeng [1 ]
Lan, Chongyu [1 ]
Luan, Tiangang [1 ]
机构
[1] Sun Yat Sen Univ, State Key Lab Biocontrol, MOE Key Lab Aquat Prod Safety, Sch Life Sci, Guangzhou 510275, Guangdong, Peoples R China
[2] So Med Univ, Hyg Detect Ctr, Sch Publ Hlth & Trop Med, Guangzhou 510515, Guangdong, Peoples R China
基金
中国国家自然科学基金;
关键词
Derivatization; Dispersive liquid-liquid microextraction (DLLME); Methyl chloroformate; Endocrine disrupting alkylphenols; Gas chromatography-mass spectrometry; ENDOCRINE-DISRUPTING CHEMICALS; SOLID-PHASE MICROEXTRACTION; AMINO-ACIDS; STEROID-HORMONES; WATER SAMPLES; EXTRACTION; CHLOROFORMATES; CHLOROPHENOLS;
D O I
10.1016/j.chroma.2010.06.030
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
A simple and fast sample preparation method for the determination of nonylphenol (NP) and octylphenol (OP) in aqueous samples by simultaneous derivatization and dispersive liquid-liquid microextraction (DLLME) was investigated using gas chromatography-mass spectrometry (GC/MS) In this method, a combined dispersant/derivatization catalyst (methanol/pyridine mixture) was firstly added to an aqueous sample, following which a derivatization reagent/extraction solvent (methyl chloroformate/chloroform) was rapidly injected to combine in situ derivatization and extraction in a single step After centrifuging, the sedimented phase containing the analytes was injected into the GC port by autosampler for analysis. Several parameters, such as extraction solvent, dispersant solvent, amount of derivatization reagent, derivatization and extraction time, pH, and ionic strength were optimized to obtain higher sensitivity for the detection of NP and OP. Under the optimized conditions', good linearity was observed in the range of 0 1-1000 mu g L-1 and 0 01-100 mu g L-1 with the limits of detection (LOD)of 0.03 mu g L-1 and 0 002 mu g L-1 for NP and OP, respectively. Water samples collected from the Pearl River were analyzed with the proposed method, the concentrations of NP and OP were found to be 2.40 +/- 0 16 mu g L-1 and 0.037 +/- 0 001 mu g L-1, respectively. The relative recoveries of the water samples spiked with different concentrations of NP and OP were in the range of 88 3-106.7%. Compared with SPME and SPE, the proposed method can be successfully applied to the rapid and convenient determination of NP and OP in aqueous samples (C) 2010 Elsevier B.V All rights reserved
引用
收藏
页码:6762 / 6768
页数:7
相关论文
共 24 条
[1]   Dispersive liquid-liquid microextraction combined with gas chromatography-flame photometric detection - Very simple, rapid and sensitive method for the determination of organophosphorus pesticides in water [J].
Berijani, Sana ;
Assadi, Yaghoub ;
Anbia, Mansoor ;
Milani Hosseini, Mohammad-Reza ;
Aghaee, Elham .
JOURNAL OF CHROMATOGRAPHY A, 2006, 1123 (01) :1-9
[2]   Simultaneous derivatization and extraction of anilines in waste water with dispersive liquid-liquid microextraction followed by gas chromatography-mass spectrometric detection [J].
Chiang, Jing-Shan ;
Huang, Shang-Da .
TALANTA, 2008, 75 (01) :70-75
[3]   Determination of chlorophenols in water samples using simultaneous dispersive liquid-liquid microextraction and derivatization followed by gas chromatography-electron-capture detection [J].
Fattahi, Nazir ;
Assadi, Yaghoub ;
Hosseini, Mohammad Reza Milani ;
Jahromi, Elham. Zeini .
JOURNAL OF CHROMATOGRAPHY A, 2007, 1157 (1-2) :23-29
[4]   Ultrasonic-assisted derivatization reaction of amino acids prior to their determination in urine by using single-drop microextraction in conjunction with gas chromatography [J].
Fiamegos, YC ;
Nanos, CG ;
Stalikas, CD .
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2004, 813 (1-2) :89-94
[5]   In-drop derivatisation liquid-phase microextraction assisted by ion-pairing transfer for the gas chromatographic determination of phenolic endocrine disruptors [J].
Fiamegos, Yiannis C. ;
Stalikas, Constantine D. .
ANALYTICA CHIMICA ACTA, 2007, 597 (01) :32-40
[6]   Dispersive liquid-liquid microextraction combined with gas chromatography-electron capture detection for the determination of polychlorinated biphenyls in soils [J].
Hu, Jia ;
Fu, Lingyan ;
Zhao, Xinna ;
Liu, Xiujuan ;
Wang, Huili ;
Wang, Xuedong ;
Dai, Liyan .
ANALYTICA CHIMICA ACTA, 2009, 640 (1-2) :100-105
[7]   Chloroformates in gas chromatography as general purpose derivatizing agents [J].
Husek, P .
JOURNAL OF CHROMATOGRAPHY B, 1998, 717 (1-2) :57-91
[8]   Fluoroalkyl chloroformates in treating amino acids for gas chromatographic analysis [J].
Husek, Petr ;
Simek, Petr ;
Hartvich, Petr ;
Zahradnickova, Helena .
JOURNAL OF CHROMATOGRAPHY A, 2008, 1186 (1-2) :391-400
[9]   Trace analysis of phenolic xenoestrogens in water samples by stir bar sorptive extraction with in situ derivatization and thermal desorption-gas chromatography-mass spectrometry [J].
Kawaguchi, M ;
Inoue, K ;
Yoshimura, M ;
Sakui, N ;
Okanouchi, N ;
Ito, R ;
Yoshimura, Y ;
Nakazawa, H .
JOURNAL OF CHROMATOGRAPHY A, 2004, 1041 (1-2) :19-26
[10]   Dispersive liquid-liquid microextraction followed by reversed phase-high performance liquid chromatography for the determination of polybrominated diphenyl ethers at trace levels in landfill leachate and environmental water samples [J].
Li, Yanyan ;
Wei, Guohui ;
Hu, Jia ;
Liu, Xiujuan ;
Zhao, Xinna ;
Wang, Xuedong .
ANALYTICA CHIMICA ACTA, 2008, 615 (01) :96-103