A comparison between stereophotogrammetry and smartphone structured light technology for three-dimensional face scanning

被引:50
作者
D'Ettorre, Giorgio [1 ]
Farronato, Marco [2 ]
Candida, Ettore [1 ]
Quinzi, Vincenzo [3 ]
Grippaudo, Cristina [4 ,5 ]
机构
[1] Univ Cattolica Sacro Cuore, Dent Inst, Orthodont Head & Neck Dept, Rome, Italy
[2] Univ Milan, Osped Maggiore Policlin, Dept Med Surg & Dent, Fdn IRCCS IRCCS Ist Ricovero & Cura Carattere Sci, Via Commenda 10, I-20122 Milan, Italy
[3] Univ Aquila, Sect Orthodont, Dept Life Hlth & Environm Sci, Laquila, Italy
[4] Fdn Policlin Univ A Gemelli IRCCS, Dent Inst, Head & Neck Dept, Rome, Italy
[5] Univ Cattolica Sacro Cuore, Dent Inst, Neck Dept, Rome, Italy
关键词
Stereophotogrammetry; Orthodontics; Facial scan; REPRODUCIBILITY; VALIDATION; RELIABILITY; ACCURACY;
D O I
10.2319/040921-290.1
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Objectives: To compare three-dimensional facial scans obtained by stereophotogrammetry with two different applications for smartphone supporting the TrueDepth system, a structured light technology. Materials and Methods: Facial scans of 40 different subjects were acquired with three different systems. The 3dMDtrio Stereophotogrammetry System (3dMD, Atlanta, Ga) was compared with a smartphone (iPhone Xs; Apple, Cupertino, Calif) equipped with the Bellus3D Face Application (version 1.6.11; Bellus3D Inc, Campbell, Calif) or Capture (version 1.2.5; Standard Cyborg Inc, San Francisco, Calif). Times of image acquisition and elaboration were recorded. The surface-to-surface deviation and the distance between 18 landmarks from 3dMD reference images to those acquired with Bellus3D or Capture were measured. Results: Capturing and processing times with the smartphone applications were considerably longer than with the 3dMD system. The surface-to-surface deviation analysis between the Bellus3D and 3dMD showed an overlap percentage of 80.01% +/- 5.92% and 56.62% +/- 7.65% within the ranges of 1 mm and 0.5 mm discrepancy, respectively. Images from Capture showed an overlap percentage of 81.40% +/- 9.59% and 56.45% +/- 11.62% within the ranges of 1 mm and 0.5 mm, respectively. Conclusions: The face image acquisition with the 3dMD device is fast and accurate, but bulky and expensive. The new smartphone applications combined with the TrueDepth sensors show promising results. They need more accuracy from the operator and more compliance from the patient because of the increased acquisition time. Their greatest advantages are related to cost and portability.
引用
收藏
页码:358 / 363
页数:6
相关论文
共 23 条
  • [1] The Accuracy of Digital Face Scans Obtained from 3D Scanners: An In Vitro Study
    Amornvit, Pokpong
    Sanohkan, Sasiwimol
    [J]. INTERNATIONAL JOURNAL OF ENVIRONMENTAL RESEARCH AND PUBLIC HEALTH, 2019, 16 (24)
  • [2] [Anonymous], 1994, Anthropometry of the Head and Face
  • [3] Validation of a vision-based, three-dimensional facial imaging system
    Ayoub, A
    Garrahy, A
    Hood, C
    White, J
    Bock, M
    Siebert, JP
    Spencer, R
    Ray, A
    [J]. CLEFT PALATE-CRANIOFACIAL JOURNAL, 2003, 40 (05) : 523 - 529
  • [4] Ayoub A F, 1996, Int J Adult Orthodon Orthognath Surg, V11, P225
  • [5] Measurement accuracy and dependence on external influences of the iPhone X TrueDepth sensor
    Breitbarth, Andreas
    Schardt, Timothy
    Kind, Cosima
    Brinkmann, Julia
    Dittrich, Paul-Gerald
    Notni, Gunther
    [J]. PHOTONICS AND EDUCATION IN MEASUREMENT SCIENCE, 2019, 11144
  • [6] Broca M., 1862, Bull De La Societe d'Anthropologie De Paris, V3, P514
  • [7] Smartphone Application as a Low-Cost Alternative for Digitizing Facial Defects: Is It Accurate Enough for Clinical Application?
    Elbashti, Mahmoud E.
    Sumita, Yuka, I
    Aswehlee, Amel M.
    Seelaus, Rosemary
    [J]. INTERNATIONAL JOURNAL OF PROSTHODONTICS, 2019, 32 (06) : 541 - 543
  • [8] A novel method for superimposition and measurements on maxillary digital 3D models-studies on validity and reliability
    Ganzer, Niels
    Feldmann, Ingalill
    Liv, Per
    Bondemark, Lars
    [J]. EUROPEAN JOURNAL OF ORTHODONTICS, 2018, 40 (01) : 45 - 51
  • [9] Are Portable Stereophotogrammetric Devices Reliable in Facial Imaging? A Validation Study of VECTRA H1 Device
    Gibelli, Daniele
    Pucciarelli, Valentina
    Cappella, Annalisa
    Dolci, Claudia
    Sforza, Chiarella
    [J]. JOURNAL OF ORAL AND MAXILLOFACIAL SURGERY, 2018, 76 (08) : 1772 - 1784
  • [10] 3D digital stereophotogrammetry: a practical guide to facial image acquisition
    Heike, Carrie L.
    Upson, Kristen
    Stuhaug, Erik
    Weinberg, Seth M.
    [J]. HEAD & FACE MEDICINE, 2010, 6