Monte Carlo simulation of the imaging properties of scintillator-coated X-ray pixel detectors

被引:9
|
作者
Hjelm, M [1 ]
Norlin, B
Nilsson, HE
Fröjdh, C
Badel, X
机构
[1] Mid Sweden Univ, Dept Informat Technol & Media, SE-85170 Sundsvall, Sweden
[2] Royal Inst Technol, Dept Microelect & Informat Technol, SE-16440 Kista, Sweden
关键词
X-ray; signal-to-noise ratio; Monte Carlo simulation; imaging; pixel detector; scintillating screen;
D O I
10.1016/S0168-9002(03)01553-5
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
The spatial resolution of scintillator-coated X-ray pixel detectors is usually limited by the isotropic light spread in the scintillator. One way to overcome this limitation is to use a pixellated scintillating layer on top of the semiconductor pixel detector. Using advanced etching and filling techniques, arrays of CsI columns have been successfully fabricated and characterized. Each CsI waveguide matches one pixel of the semiconductor detector, limiting the spatial spread of light. Another concept considered in this study is to detect the light emitted from the scintillator by diodes formed in the silicon pore walls. There is so far no knowledge regarding the theoretical limits for these two approaches, which makes the evaluation of the fabrication process difficult. In this work we present numerical calculations of the signal-to-noise ratio (SNR) for detector designs based on scintillator-filled pores in silicon. The calculations are based on separate Monte Carlo (MC) simulations of X-ray absorption and light transport in scintillator waveguides. The resulting data are used in global MC simulations of flood exposures of the detector array, from which the SNR values are obtained. Results are presented for two scintillator materials, namely CsI (Tl) and GADOX. (C) 2003 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:76 / 85
页数:10
相关论文
共 50 条
  • [21] A Monte Carlo simulation of x-ray mammography
    Spyrou, G
    Panayiotakis, G
    Tzanakos, G
    PROCEEDINGS OF THE 18TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOL 18, PTS 1-5, 1997, 18 : 842 - 843
  • [22] Monte Carlo simulations in X-ray imaging
    Giersch, Juergen
    Durst, Juergen
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2008, 591 (01): : 300 - 305
  • [23] Cascade modeling of pixelated scintillator detectors for x-ray imaging
    Kim, Ho Kyung
    Yun, Seung Man
    Ko, Jong Soo
    Cho, Gyuseong
    Graeve, Thorsten
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2008, 55 (03) : 1357 - 1366
  • [24] Monte Carlo simulation of the response functions of CdTe detectors to be applied in x-ray spectroscopy
    Tomal, A.
    Santos, J. C.
    Costa, P. R.
    Lopez Gonzales, A. H.
    Poletti, M. E.
    APPLIED RADIATION AND ISOTOPES, 2015, 100 : 32 - 37
  • [25] A Monte Carlo ray-tracing simulation of coherent X-ray diffractive imaging
    Fevola, Giovanni
    Knudsen, Erik Bergback
    Ramos, Tiago
    Carbone, Dina
    Andreasen, Jens Wenzel
    JOURNAL OF SYNCHROTRON RADIATION, 2020, 27 (134-145) : 134 - 145
  • [26] Monte Carlo simulation of image properties of an X-ray intensifying screen
    Wang, Y
    Wang, JJ
    Wang, KL
    Liu, GZ
    Liu, YQ
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2000, 448 (03): : 567 - 570
  • [27] X-ray radiography of HPGe detectors for Monte Carlo simulations
    Pohuliai, Serhii
    Vlasenko, Andrey
    Malgin, Vladislav
    Kanapelka, Marina
    APPLIED RADIATION AND ISOTOPES, 2023, 198
  • [28] Simulation of the X-ray response of scintillator coated silicon CCDs
    Frojdh, C.
    Nilsson, H.E.
    Nelvig, P.
    Petersson, C.S.
    IEEE Transactions on Nuclear Science, 1998, 45 (3 pt 1): : 374 - 378
  • [29] Monte Carlo Simulation of X-Ray Imaging Using a Graphics Processing Unit
    Badal, Andreu
    Badano, Aldo
    2009 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-5, 2009, : 4081 - 4084
  • [30] Monte Carlo simulation on X-ray backlighting imaging in fast ignition research
    Han, Dan
    Zhao, Zongqing
    Shan, Lianqiang
    Tan, Fang
    Qiangjiguang Yu Lizishu/High Power Laser and Particle Beams, 2012, 24 (08): : 1861 - 1866