Early hemodynamic and neurohormonal response after transcatheter aortic valve implantation

被引:29
作者
Sherif, Mohammad A. [1 ,2 ]
Abdel-Wahab, Mohamed [2 ]
Awad, Omar [2 ]
Geist, Volker
El-Shahed, Ghada [2 ]
Semmler, Reinhard [3 ]
Tawfik, Mazen [2 ]
Khattab, Ahmed A. [2 ]
Richardt, Doreen [4 ]
Richardt, Gert
Toelg, Ralph
机构
[1] Segeberger Kliniken GmbH, Herz Kreislauf Zentrum, Dept Cardiol, D-23795 Bad Segeberg, Germany
[2] Ain Shams Univ Hosp, Dept Cardiol, Cairo, Egypt
[3] Segeberger Kliniken GmbH, Dept Cardiovasc Surg, D-23795 Bad Segeberg, Germany
[4] Schleswig Holstein Univ Hosp, Dept Cardiovasc Surg, Lubeck, Germany
关键词
PROSTHESIS-PATIENT MISMATCH; NATRIURETIC PEPTIDE; DOPPLER-ECHOCARDIOGRAPHY; FOLLOW-UP; STENOSIS; REPLACEMENT; REGURGITATION;
D O I
10.1016/j.ahj.2010.07.017
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background The conventional surgical aortic bioprostheses used for treatment of aortic stenosis (AS) are inherently stenotic in nature. The more favorable mechanical profile of the Medtronic CoreValve bioprosthesis may translate into a better hemodynamic and neurohormonal response. Patients and Methods The early hemodynamic and neurohormonal responses of 56 patients who underwent successful transcatheter aortic valve implantation (TAVI) using the Medtronic CoreValve bioprosthesis for severe symptomatic AS were compared with those of 36 patients who underwent surgical aortic valve replacement (SAVR) using tissue valves in the same period. Results At baseline, patients in the TAVI and SAVR group had comparable indexed aortic valve area (0.33 +/- 0.1 vs 0.34 +/- 0.1 cm(2), respectively; P=.69) and mean transvalvular gradient (51.1 +/- 16.5 vs 53.1 +/- 14.3 mm Hg, respectively; P=.56). At 30-day follow-up, mean transvalvular gradient was lower in the TAVI group than in the SAVR group (10.3 +/- 4 vs 13.1 +/- 6.2 mm Hg, respectively; P=.015), and the indexed aortic valve area was larger in the TAVI group (1.0 +/- 0.14 vs 0.93 +/- 0.13 cm(2)/m(2); P=.017). There was a trend toward a higher incidence of moderate patient-prosthesis mismatch in the surgical group compared with the TAVI group (30.5% vs 17.8%, respectively; P=.11). The overall incidence of prosthetic regurgitation (any degree) was higher in the TAVI group than in the SAVR group (85.7% vs 16.7%, respectively; P<.00001). The left ventricular mass index decreased after TAVI (175.1 +/- 61.8 vs 165.6 +/- 57.2 g/m(2); P=.0003) and remained unchanged after SAVR (165.1 +/- 50.6 vs 161 +/- 64.8 g/m(2); P=.81). Similarly, NT-ProBNP decreased after TAVI (3,479 +/- 2,716 vs 2,533 +/- 1,849 pg/mL; P=.033) and remained unchanged after SAVR (1,836 +/- 2,779 vs 1,689 +/- 1,533 pg/mL; P=.78). There was a modest correlation between natriuretic peptides and left ventricular mass index in the whole cohort (r=0.4, P=.013). Conclusion In patients with severe AS, TAVI resulted in lower transvalvular gradients and higher valve areas than SAVR. Such hemodynamic performance after TAVI may have contributed to early initiation of a reverse cardiac remodeling process and a decrease in natriuretic peptides. (Am Heart J 2010;160:862-9.)
引用
收藏
页码:862 / 869
页数:8
相关论文
共 26 条
  • [1] Incidence, associated factors and evolution of non-severe functional mitral regurgitation in patients with severe aortic stenosis undergoing aortic valve replacement
    Caballero-Borrego, Juan
    Gomez-Doblas, Juan Jose
    Cabrera-Bueno, Fernando
    Garcia-Pinilla, Jose Manuel
    Maria Melero, Jose
    Porras, Carlos
    Olalla, Eduardo
    De Teresa Galvan, Eduardo
    [J]. EUROPEAN JOURNAL OF CARDIO-THORACIC SURGERY, 2008, 34 (01) : 62 - 66
  • [2] Echocardiography for transcatheter aortic valve implantation
    Chin, Derek
    [J]. EUROPEAN JOURNAL OF ECHOCARDIOGRAPHY, 2009, 10 (01): : I21 - I29
  • [3] Comparison of the Hemodynamic Performance of Percutaneous and Surgical Bioprostheses for the Treatment of Severe Aortic Stenosis
    Clavel, Marie-Annick
    Webb, John G.
    Pibarot, Philippe
    Altwegg, Lukas
    Dumont, Eric
    Thompson, Chris
    De Larochelliere, Robert
    Doyle, Daniel
    Masson, Jean-Bernard
    Bergeron, Sebastien
    Bertrand, Olivier F.
    Rodes-Cabau, Josep
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2009, 53 (20) : 1883 - 1891
  • [4] de Jaegere Peter, 2007, EuroIntervention, V2, P500
  • [5] De Jaegere Peter P Th, 2008, EuroIntervention, V4, P351, DOI 10.4244/EIJV4I3A63
  • [6] ECHOCARDIOGRAPHIC ASSESSMENT OF LEFT-VENTRICULAR HYPERTROPHY - COMPARISON TO NECROPSY FINDINGS
    DEVEREUX, RB
    ALONSO, DR
    LUTAS, EM
    GOTTLIEB, GJ
    CAMPO, E
    SACHS, I
    REICHEK, N
    [J]. AMERICAN JOURNAL OF CARDIOLOGY, 1986, 57 (06) : 450 - 458
  • [7] Gegouskov V A, 2003, Swiss Surg, V9, P247, DOI 10.1024/1023-9332.9.5.247
  • [8] Increased plasma natriuretic peptide levels reflect symptom onset in aortic stenosis
    Gerber, IL
    Stewart, RAH
    Legget, ME
    West, TM
    French, RL
    Sutton, TM
    Yandle, TG
    French, JK
    Richards, AM
    White, HD
    [J]. CIRCULATION, 2003, 107 (14) : 1884 - 1890
  • [9] Percutaneous aortic valve replacement for severe aortic stenosis in high-rick patients using the second- and current third-generation self-expanding CoreValve prosthesis - Device success and 30-day clinical outcome
    Grube, Eberhard
    Schuler, Gerhard
    Buellesfeld, Lutz
    Gerckens, Ulrich
    Linke, Axel
    Wenaweser, Peter
    Sauren, Barthel
    Mohr, Friedrich-Wilhelm
    Walther, Thomas
    Zickmann, Bernfried
    Iversen, Stein
    Felderhoff, Thomas
    Cartier, Raymond
    Bonan, Raoul
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2007, 50 (01) : 69 - 76
  • [10] Plasma levels of brain and atrial natriuretic peptides elevate in proportion to left ventricular end-systolic wall stress in patients with aortic stenosis
    Ikeda, T
    Matsuda, K
    Itoh, H
    Shirakami, G
    Miyamoto, Y
    Yoshimasa, T
    Nakao, K
    Ban, T
    [J]. AMERICAN HEART JOURNAL, 1997, 133 (03) : 307 - 314