Bioresorbable ureteral stents from natural origin polymers

被引:43
作者
Barros, Alexandre A. [1 ,2 ]
Duarte, Ana Rita C. [1 ,2 ]
Pires, Ricardo A. [1 ,2 ]
Sampaio-Marques, Belem [2 ,3 ]
Ludovico, Paula [2 ,3 ]
Lima, Estevao [2 ,3 ]
Mano, Joao F. [1 ,2 ]
Reis, Rui L. [1 ,2 ]
机构
[1] Univ Minho, Res Grp Biomat Biodegradables & Biomimet 3Bs, Headquarters European Inst Excellence Tissue Engn, P-4806909 Taipas, Guimaraes, Portugal
[2] ICVS 3Bs PT Govt Associate Lab, Braga, Portugal
[3] Univ Minho, Sch Hlth Sci, Life & Hlth Sci Res Inst ICVS, Braga, Portugal
关键词
aerogel; hydrogel; natural polymers; bioresorbable polymers; kidney stones; supercritical fluid technology; ureteral stents; DRAINAGE STENT; DEGRADATION; RESISTANCE; ENCRUSTATION; BIOMATERIAL; HYDROGEL; BLENDS;
D O I
10.1002/jbm.b.33237
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
In this work, stents were produced from natural origin polysaccharides. Alginate, gellan gum, and a blend of these with gelatin were used to produce hollow tube (stents) following a combination of templated gelation and critical point carbon dioxide drying. Morphological analysis of the surface of the stents was carried out by scanning electron microscopy. Indwelling time, encrustation, and stability of the stents in artificial urine solution was carried out up to 60 days of immersion. In vitro studies carried out with simulated urine demonstrated that the tubes present a high fluid uptake ability, about 1000%. Despite this, the materials are able to maintain their shape and do not present an extensive swelling behavior. The bioresorption profile was observed to be highly dependent on the composition of the stent and it can be tuned. Complete dissolution of the materials may occur between 14 and 60 days. Additionally, no encrustation was observed within the tested timeframe. The ability to resist bacterial adherence was evaluated with Gram-positive Staphylococcus aureus and two Gram-negatives Escherichia coli DH5 alpha and Klebsiella oxytoca. For K. oxytoca, no differences were observed in comparison with a commercial stent (Biosoft((R)) duo, Porges), although, for S. aureus all tested compositions had a higher inhibition of bacterial adhesion compared to the commercial stents. In case of E. coli, the addition of gelatin to the formulations reduced the bacterial adhesion in a highly significant manner compared to the commercial stents. The stents produced by the developed technology fulfill the requirements for ureteral stents and will contribute in the development of biocompatible and bioresorbable urinary stents. (c) 2014 Wiley Periodicals, Inc. J Biomed Mater Res Part B: Appl Biomater, 103B: 608-617, 2015.
引用
收藏
页码:608 / 617
页数:10
相关论文
共 46 条
  • [11] Alginate/gelatin blend films and their properties for drug controlled release
    Dong, Zhanfeng
    Wang, Qun
    Du, Yumin
    [J]. JOURNAL OF MEMBRANE SCIENCE, 2006, 280 (1-2) : 37 - 44
  • [12] Unleashing the potential of supercritical fluids for polymer processing in tissue engineering and regenerative medicine
    Duarte, Ana Rita C.
    Santo, Vitor E.
    Alves, Anabela
    Siiva, Simone S.
    Moreira-Silva, Joana
    Silva, Tiago H.
    Marques, Alexandra P.
    Sousa, Rui A.
    Gomes, Manuela E.
    Mano, Joao F.
    Reis, Rui L.
    [J]. JOURNAL OF SUPERCRITICAL FLUIDS, 2013, 79 : 177 - 185
  • [13] The role of organic solvent on the preparation of chitosan scaffolds by supercritical assisted phase inversion
    Duarte, Ana Rita C.
    Mano, Joao F.
    Reis, Rui L.
    [J]. JOURNAL OF SUPERCRITICAL FLUIDS, 2012, 72 : 326 - 332
  • [14] POLYURETHANE INTERNAL URETERAL STENTS IN TREATMENT OF STONE PATIENTS - MORBIDITY RELATED TO INDWELLING TIMES
    ELFAQIH, SR
    SHAMSUDDIN, AB
    CHAKRABARTI, A
    ATASSI, R
    KARDAR, AH
    OSMAN, MK
    HUSAIN, I
    [J]. JOURNAL OF UROLOGY, 1991, 146 (06) : 1487 - 1491
  • [15] Preparation and characterization of alginate/gelatin blend fibers
    Fan, LH
    Du, YM
    Huang, RH
    Wang, Q
    Wang, XH
    Zhang, LN
    [J]. JOURNAL OF APPLIED POLYMER SCIENCE, 2005, 96 (05) : 1625 - 1629
  • [16] Comparison of a biodegradable ureteral stent versus the traditional double-J stent for the treatment of ureteral injury: an experimental study
    Fu, Wei-Jun
    Wang, Zhong-Xin
    Li, Gang
    Cui, Fu-Zhai
    Zhang, Yuanyuan
    Zhang, Xu
    [J]. BIOMEDICAL MATERIALS, 2012, 7 (06)
  • [17] Gogra A.B., 2010, Journal of American Science, V6, P78
  • [18] Mechanical performance of polyurethane ureteral stents in vitro and ex vivo
    Gorman, SP
    Jones, DS
    Bonner, MC
    Akay, M
    Keane, PF
    [J]. BIOMATERIALS, 1997, 18 (20) : 1379 - 1383
  • [19] Antibacterial surfaces: the quest for a new generation of biomaterials
    Hasan, Jafar
    Crawford, Russell J.
    Lvanova, Elena P.
    [J]. TRENDS IN BIOTECHNOLOGY, 2013, 31 (05) : 31 - 40
  • [20] New Metallic Ureteral Stents: Improved Tensile Strength and Resistance to Extrinsic Compression
    Hendlin, Kari
    Korman, Emily
    Monga, Manoj
    [J]. JOURNAL OF ENDOUROLOGY, 2012, 26 (03) : 271 - 274