Biomechanical effect of intertrochanteric curved varus osteotomy on stress reduction in femoral head osteonecrosis: a finite element analysis

被引:11
作者
Wang, Yuzhu [1 ]
Yamako, Go [2 ]
Okada, Takato [3 ]
Arakawa, Hideki [1 ]
Nakamura, Yoshihiro [1 ]
Chosa, Etsuo [1 ]
机构
[1] Univ Miyazaki, Fac Med, Dept Orthopaed Surg, Miyazaki, Miyazaki, Japan
[2] Univ Miyazaki, Fac Engn, Dept Mech Engn, Miyazaki, Miyazaki, Japan
[3] Univ Miyazaki, Grad Sch Engn, Miyazaki, Miyazaki, Japan
关键词
TOTAL HIP-ARTHROPLASTY; PERIACETABULAR OSTEOTOMY; ROTATIONAL OSTEOTOMY; CORE DECOMPRESSION; AVASCULAR NECROSIS; TANTALUM ROD; VERIFICATION; VALIDATION; COLLAPSE; SENSITIVITY;
D O I
10.1186/s13018-021-02614-z
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background Intertrochanteric curved varus osteotomy (CVO) has been widely used to remove the necrotic bone away from the weight-bearing portion in the treatment of osteonecrosis of the femoral head (ONFH). However, whether all types of necrosis will benefit from CVO, in terms of the stress level, the effect of different center-edge (CE) angles of acetabulum on stress distribution of necrosis after CVO, and the relationship between the intact ratio and the stress of necrosis, has never been addressed. The purpose of the study was to evaluate the influence of CVO on the stress reduction in necrotic bone using a finite element analysis (FEA) with different CE angles. Methods CVO finite element models of the hip joint were simulated with a lesion of 60 degrees. The osteotomy angles were divided into four configurations (15 degrees, 20 degrees, 25 degrees, and 30 degrees), and three types (A, B, and C1) of lesions were established based on the Japanese Investigation Committee (JIC) classification. In addition, two CE angles (18 degrees and 33 degrees) of acetabulum were considered. The maximum and mean von Mises stress were analyzed in terms of the necrotic bone by a physiological loading condition. Moreover, the correlation of the intact ratio measured in 3D and the stress distribution after CVO was analyzed. Results Stress reduction was obtained after CVO. For type B, the CVO angle was 20 degrees (0.61 MPa), and for type C1, the CVO angle was 30 degrees (0.77 MPa), if the mean stress level was close to type A (0.61 MPa), as a standard. The maximum and mean von Mises stress were higher in the CE angle of 18 degrees models, respectively. The intact ratio measured in 3D had a good negative correlation with stress after CVO and had more influence on stress distribution in comparison to other geometric parameters. Conclusions For making decisions about the biomechanics of CVO, a CVO angle of > 20 degrees was recommended for type B and > 30 degrees was safe for type C1. The risk of progressive collapse was increased in the insufficient situation of the weight-bearing portion after CVO. The intact ratio could provide information about clinical outcomes and stress distribution after CVO.
引用
收藏
页数:10
相关论文
共 50 条
[1]   Specimen-specific modeling of hip fracture pattern and repair [J].
Ali, Azhar A. ;
Cristofolini, Luca ;
Schileo, Enrico ;
Hu, Haixiang ;
Taddei, Fulvia ;
Kim, Raymond H. ;
Rullkoetter, Paul J. ;
Laz, Peter J. .
JOURNAL OF BIOMECHANICS, 2014, 47 (02) :536-543
[2]   Subject-specific finite element model of the pelvis: Development, validation and sensitivity studies [J].
Anderson, AE ;
Peters, CL ;
Tuttle, BD ;
Weiss, JA .
JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME, 2005, 127 (03) :364-373
[3]  
Anderson Andrew E., 2007, Computer Methods in Biomechanics and Biomedical Engineering, V10, P171, DOI 10.1080/10255840601160484
[4]   Finite Element Analysis of the Multiple Drilling Technique for Early Osteonecrosis of the Femoral Head [J].
Bae, Ji Yong ;
Kwak, Dai Soon ;
Park, Kyung Soon ;
Jeon, Insu .
ANNALS OF BIOMEDICAL ENGINEERING, 2013, 41 (12) :2528-2537
[5]  
BAKER KJ, 1989, CLIN ORTHOP RELAT R, P183
[6]   A NON-LINEAR FINITE-ELEMENT ANALYSIS OF SOME EARLY COLLAPSE PROCESSES IN FEMORAL-HEAD OSTEONECROSIS [J].
BROWN, TD ;
MUTSCHLER, TA ;
FERGUSON, AB .
JOURNAL OF BIOMECHANICS, 1982, 15 (09) :705-715
[7]   Selection of fixation devices in proximal femur rotational osteotomy: clinical complications and finite element analysis [J].
Chen, WP ;
Tai, CL ;
Shih, CH ;
Hsieh, PH ;
Leou, MC ;
Lee, MS .
CLINICAL BIOMECHANICS, 2004, 19 (03) :255-262
[8]   The clinical and radiographic results of intertrochanteric curved varus osteotomy for idiopathic osteonecrosis of the femoral head [J].
Hamanishi, Michio ;
Yasunaga, Yuji ;
Yamasaki, Takuma ;
Mori, Ryo ;
Shoji, Takeshi ;
Ochi, Mitsuo .
ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 2014, 134 (03) :305-310
[9]   Correlation between radiographic measures of acetabular morphology with 3D femoral head coverage in patients with acetabular retroversion [J].
Hansen, Benjamin J. ;
Harris, Michael D. ;
Anderson, Lucas A. ;
Peters, Christopher L. ;
Weiss, Jeffrey A. ;
Anderson, Andrew E. .
ACTA ORTHOPAEDICA, 2012, 83 (03) :233-239
[10]   Finite element predictions of cartilage contact mechanics in hips with retroverted acetabula [J].
Henak, C. R. ;
Carruth, E. D. ;
Anderson, A. E. ;
Harris, M. D. ;
Ellis, B. J. ;
Peters, C. L. ;
Weiss, J. A. .
OSTEOARTHRITIS AND CARTILAGE, 2013, 21 (10) :1522-1529