Predictive role of SEC in mitral restenosis following successful percutaneous balloon mitral valvuloplasty (PBMV)

被引:0
|
作者
Tasbulak, Omer [1 ]
Duran, Mustafa [2 ]
Sahin, Ahmet Anil [3 ]
Demir, All Riza [1 ]
Uygur, Begum [1 ]
Avci, Yalcin [1 ]
Celik, Omer [1 ]
Yalcin, Ahmet Arif [1 ]
Erturk, Mehmet [1 ]
机构
[1] Univ Hlth Sci, Mehmet Akif Ersoy Thorac & Cardiovasc Surg Traini, Dept Cardiol, Istanbul, Turkey
[2] Konya Training & Res Hosp, Dept Cardiol, Konya, Turkey
[3] Istinye Univ, Liv Hosp Bahcesehir, Fac Med, Dept Cardiol, Istanbul, Turkey
来源
ANNALS OF CLINICAL AND ANALYTICAL MEDICINE | 2022年 / 13卷 / 08期
关键词
Percutaneous Balloon Mitral Valvuloplasty; Mitral Restenosis; Spontaneous Echo Contrast; SPONTANEOUS ECHO CONTRAST; THROMBOEMBOLIC RISK; P-SELECTIN; STENOSIS; VALVOTOMY; ECHOCARDIOGRAPHY; IMMEDIATE; PLATELET; VALVE;
D O I
10.4328/ACAM.21143
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Aim: The aim of this study was to investigate the predictive role of spontaneous echo contrast (SEC) in mitral restenosis after percutaneous balloon mitral valvuloplasty (PBMV). Material and Methods: We retrospectively analyzed 341 consecutive patients who underwent PBMV at our hospital. Subjects who participated in the study were assigned to two groups: patients who had demonstrable SEC in the left atrial cavity and left atrial appendage and patients who did not have SEC in the left atrial cavity and left atrial appendage. For each group, the following variables were analyzed: demographic characteristics, past medical records, laboratory values, transthoracic echocardiography (TTE) and transesophageal echocardiography (TEE) parameters. Results: Compared to patients without SEC, patients with SEC were older, had a higher incidence of diabetes mellitus (DM), ischemic stroke and AF (p<0.05). With respect to TTE and TEE measurements, patients with SEC had lower estimated pre-procedural left ventricular ejection fraction (LVEF), a smaller calculated mitral valve area (MVA), a larger left atrial (LA) dimension and higher estimated preprocedural Wilkins score (p<0.05). In addition, the incidence of mitral restenosis following PBMV was significantly higher in patients with SEC compared to patients without SEC ( p <0.05), and this difference was more apparent in patients with grade 3-4 SEC compared to those with grade 1-2 SEC (p<0.05) Discussion: Our data showed that there is a strong association between SEC formation in the left atrium and left atrial appendage and mitral restenosis following PBMV
引用
收藏
页码:873 / 878
页数:6
相关论文
共 50 条
  • [21] Successful percutaneous balloon mitral valvuloplasty in patients with left atrial appendage thrombus
    Akilli, Hakan
    Aribas, Alpay
    Altunbas, Gokhan
    Ozdemir, Kurtulus
    ANATOLIAN JOURNAL OF CARDIOLOGY, 2013, 13 (01): : 73 - 74
  • [22] EFFICACY AND IMMEDIATE OUTCOMES OF PERCUTANEOUS BALLOON MITRAL VALVULOPLASTY IN SEVERE RHEUMATIC MITRAL STENOSIS
    Ihsan, Atif
    Ali, Jabar
    Gandhi, Sanjay
    Khan, Yasir
    Hassan, Zair
    Jan, Muneeb Ullah
    Kumari, Usha
    PAKISTAN HEART JOURNAL, 2022, 55 (02): : 140 - 144
  • [23] Immediate results of redo percutaneous mitral valvuloplasty
    Fennira, S.
    Antit, S.
    Sioua, S.
    Ellouze, Y.
    Kamoun, S.
    Mrabett, K.
    Zairi, I.
    Kraiem, S.
    ANNALES DE CARDIOLOGIE ET D ANGEIOLOGIE, 2013, 62 (02): : 108 - 115
  • [24] Impact of Atrioventricular Compliance on Clinical Outcome of Patients Undergoing Successful Percutaneous Balloon Mitral Valvuloplasty
    Mahfouz, Ragab A.
    Elawady, Waled
    Hossein, Ekhlas
    Yosri, Ahmad
    ECHOCARDIOGRAPHY-A JOURNAL OF CARDIOVASCULAR ULTRASOUND AND ALLIED TECHNIQUES, 2013, 30 (10): : 1187 - 1193
  • [25] In-hospital and Readmission Outcomes With Percutaneous Balloon Mitral Valvuloplasty
    Elkaryoni, Ahmed
    Hussain, Fizza
    Chahine, Nicole
    Khan, Rizwan
    Malhotra, Akshay
    Mentias, Amgad
    Alkhouli, Mohamad A.
    Sharaf, Barry L.
    Gordon, Paul
    Lopez, John J.
    Aronow, Herbert D.
    Abbott, Jinnette Dawn
    Saad, Marwan
    CURRENT PROBLEMS IN CARDIOLOGY, 2022, 47 (12)
  • [26] Repeat Percutaneous Balloon Mitral Valvotomy vs Mitral Valve Replacement in Patients With Restenosis After Previous Balloon Mitral Valvotomy and Unfavorable Valve Characteristics
    Aslanabadi, Naser
    Golmohammadi, Ali
    Sohrabi, Bahram
    Kazemi, Babak
    CLINICAL CARDIOLOGY, 2011, 34 (06) : 401 - 406
  • [27] Effectiveness of Percutaneous Balloon Mitral Valvuloplasty for Rheumatic Mitral Stenosis with Mild to Severe Mitral Regurgitation
    Lu, LinXiang
    Hong, Lang
    Fang, Jun
    Chen, LiangLong
    BIOMED RESEARCH INTERNATIONAL, 2016, 2016
  • [28] Role of three dimensional transesophageal echocardiography in predicting mitral regurgitation after percutaneous balloon mitral valvuloplasty
    Alkhouly, Abdelaal Alsayed
    Al-Amin, Ali Mohammad
    Mukarrab, Moustafa Ibraheem
    INDIAN HEART JOURNAL, 2018, 70 (06) : 836 - 842
  • [29] Copeptin Level and Copeptin Response to Percutaneous Balloon Mitral Valvuloplasty in Mitral Stenosis
    Gunebakmaz, Ozgur
    Celik, Ahmet
    Inanc, M. Tugrul
    Duran, Mustafa
    Karakaya, Ekrem
    Tulmac, Murat
    Akpek, Mahmut
    Sarli, Bahadir
    Ergin, Ali
    Topsakal, Ramazan
    CARDIOLOGY, 2011, 120 (04) : 221 - 226
  • [30] Feasibility and effectiveness of percutaneous balloon mitral valvuloplasty under echocardiographic guidance only
    Liu, Yao
    Guo, Gai-Li
    Wen, Bin
    Wang, Shouzheng
    Ou-Yang, Wen-Bin
    Xie, Yongquan
    Pan, Xiang-Bin
    ECHOCARDIOGRAPHY-A JOURNAL OF CARDIOVASCULAR ULTRASOUND AND ALLIED TECHNIQUES, 2018, 35 (10): : 1507 - 1511