A vacuum-formable mattress for veterinary radiotherapy positioning: Comparison with conventional methods

被引:25
作者
Green, EM [1 ]
Forrest, LJ [1 ]
Adams, WM [1 ]
机构
[1] Univ Wisconsin, Sch Vet Med, Dept Surg Sci, Madison, WI 53706 USA
关键词
radiotherapy; canine; feline; immobilization;
D O I
10.1111/j.1740-8261.2003.tb00488.x
中图分类号
S85 [动物医学(兽医学)];
学科分类号
0906 ;
摘要
This prospective study was undertaken to compare the positioning repeatability and setup time of a rigid immobilization device (Vac-Lok(TM) mattress*) to conventional positioning methods (sandbags, tape, foam wedges) in the clinical veterinary radiotherapy setting. Positioning repeatability was determined by using port films to verify appropriate patient positioning. Setup time was determined by recording the time required to set up each patient using each positioning method. Sixty-seven patients receiving radiotherapy were positioned using both the Vac-Lok(TM) mattresses and conventional positioning methods during their treatments. Seventy-eight total sites were treated. Forty-eight were treated daily (Monday through Friday, 2 to 4 weeks) and 30 were treated once weekly (4 weeks). Patients were grouped according to the site treated: head (29), neck/body (24), and limb (25). Vac-Lok(TM) mattresses were similar to conventional means in positioning repeatability and setup time. Vac-Lok(TM) mattresses are potentially advantageous in specific situations, including use during pre-radiotherapy tumor imaging. These mattresses are not recommended for distal limb positioning.
引用
收藏
页码:476 / 479
页数:4
相关论文
共 9 条
  • [1] Impact of cradle immobilization on setup reproducibility during external beam radiation therapy for lung cancer
    Bentel, GC
    Marks, LB
    Krishnamurthy, R
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1997, 38 (03): : 527 - 531
  • [2] Measurement of patient positioning errors in three-dimensional conformal radiotherapy of the prostate
    Hanley, J
    Lumley, MA
    Mageras, GS
    Sun, J
    Zelefsky, MJ
    Leibel, SA
    Fuks, Z
    Kutcher, GJ
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1997, 37 (02): : 435 - 444
  • [3] A NEW SYSTEM FOR PATIENT FIXATION IN RADIOTHERAPY
    JAKOBSEN, A
    IVERSEN, P
    GADEBERG, C
    HANSEN, JL
    HJELMHANSEN, M
    [J]. RADIOTHERAPY AND ONCOLOGY, 1987, 8 (02) : 145 - 151
  • [4] Comparison of the accuracy of positioning devices for radiation therapy of canine and feline head tumors
    Kippenes, H
    Gavin, PR
    Sande, RD
    Rogers, D
    Sweet, V
    [J]. VETERINARY RADIOLOGY & ULTRASOUND, 2000, 41 (04) : 371 - 376
  • [5] Light K L, 1992, Med Dosim, V17, P135
  • [6] Radiotherapy of pelvic malignancies: impact of two types of rigid immobilisation devices on localisation errors
    Mitine, C
    Hoornaert, MT
    Dutreix, A
    Beauduin, M
    [J]. RADIOTHERAPY AND ONCOLOGY, 1999, 52 (01) : 19 - 27
  • [7] Influence of a vac-fix immobilization device on the accuracy of patient positioning during routine breast radiotherapy
    Nalder, CA
    Bidmead, AM
    Mubata, CD
    Tait, D
    Beardmore, C
    [J]. BRITISH JOURNAL OF RADIOLOGY, 2001, 74 (879) : 249 - 254
  • [8] Pradier O, 1998, Cancer Radiother, V2, P359, DOI 10.1016/S1278-3218(98)80347-8
  • [9] Verhey, 1995, Semin Radiat Oncol, V5, P100, DOI 10.1016/S1053-4296(95)80004-2