Prospective study comparing two iodine concentrations for multidetector computed tomography of the pancreas

被引:1
|
作者
Liu, Y. [1 ]
Xu, X. Q. [1 ]
Lin, X. Z. [1 ]
Song, Q. [1 ]
Chen, K. M. [1 ]
机构
[1] Shanghai Jiao Tong Univ, Sch Med, Dept Radiol, Ruijin Hosp, Shanghai 200025, Peoples R China
来源
RADIOLOGIA MEDICA | 2010年 / 115卷 / 06期
关键词
Pancreas; Pancreatic neoplasm; Contrast media; X-ray computed tomography; HELICAL CT; CONTRAST MATERIAL; SALINE FLUSH; ENHANCEMENT; INJECTION; ARTERIAL; MEDIA; PHASE;
D O I
10.1007/s11547-010-0544-x
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose. The authors sought to determine the influence of two different iodine concentrations of nonionic contrast media (cm) on contrast enhancement in pancreatic computed tomography angiography (CTA). Materials and methods. Sixty patients with clinically suspected or known pancreatic disease underwent pancreatic CTA. The patients were randomly assigned to group A (n=30) and group B (n=30). The contrast agent was injected with iodine concentrations of 400mgI/ml(Iomeron 400) in group A and 300mgl/ml(lopamidol 300) in group B with the same total iodine dose (36 g). Arterial and portal venous phase contrast enhancement of the vessels, organs and pancreatic masses was measured, and blinded qualitative image assessment was performed by two expert radiologists. Results. In the arterial and portal venous phase, the highly concentrated cm led to significantly greater enhancement in the abdominal main vessels, pancreas and pancreatic carcinoma than did the low concentrated cm. No statistically significant attenuation differences were measured between pancreatic carcinomas and the pancreatic parenchyma in the arterial and portal venous phase between group A and B. The overall trend for both readers was to assign higher scores to group A than group B. Conclusions. The higher iodine concentration leads to greater contrast enhancement of abdominal vessels and organs in pancreatic CTA. Detection and demarcation of hypovascular pancreatic carcinoma was not found to be improved by the higher iodine concentration.
引用
收藏
页码:898 / 905
页数:8
相关论文
共 50 条
  • [31] Computed tomography reconstruction from two transmission measurements for iodine-marked cancer detection
    Kanno, Ikuo
    Shima, Kazunari
    Shimazaki, Hironobu
    Yamashita, Yoshiki
    Watanabe, Kenichi
    Ohtaka, Masahiko
    Hashimoto, Makoto
    Ara, Kuniaki
    Onabe, Hideaki
    JOURNAL OF NUCLEAR SCIENCE AND TECHNOLOGY, 2013, 50 (10) : 1020 - 1033
  • [32] Acinar cell carcinoma of the pancreas: computed tomography features-a study of 15 patients
    Raman, Siva P.
    Hruban, Ralph H.
    Cameron, John L.
    Wolfgang, Christopher L.
    Kawamoto, Satomi
    Fishman, Elliot K.
    ABDOMINAL IMAGING, 2013, 38 (01): : 137 - 143
  • [33] Prospective Electrocardiogram-Gated Delayed Enhanced Multidetector Computed Tomography Accurately Quantifies Infarct Size and Reduces Radiation Exposure
    Chang, Hyuk-Jae
    George, Richard T.
    Schuleri, Karl H.
    Evers, Kristine
    Kitagawa, Kakuya
    Lima, Joao A. C.
    Lardo, Albert C.
    JACC-CARDIOVASCULAR IMAGING, 2009, 2 (04) : 412 - 420
  • [34] Prospective study to compare high resolution computed tomography and magnetic resonance imaging for the detection of pancreatic neoplasms:: Use of intravenous and oral contrast media
    Fink, C
    Grenacher, L
    Hansmann, HJ
    Düx, M
    Leipold, R
    Spielhaupter, E
    Kauffmann, GW
    Richter, GM
    ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN, 2001, 173 (08): : 724 - 730
  • [35] Multidetector computed tomography in the study of pancreatic metastasesLa tomografia computerizzata multidetettore nello studio delle metastasi pancreatiche
    G. Angelelli
    M. Mancini
    P. Pignataro
    P. Pedote
    A. Scardapane
    La radiologia medica, 2012, 117 (3) : 369 - 377
  • [36] The Value of Low-dose Prospective Dual-energy Computed Tomography with Iodine Mapping in the Diagnosis of Gastric Cancer
    Wang, Lifeng
    Jin, Xingxing
    Qiao, Zhenguo
    Xu, Bin
    Shen, Jiaqing
    CURRENT MEDICAL IMAGING, 2020, 16 (04) : 433 - 437
  • [37] Recommended Iodine Dose for Multiphasic Contrast-Enhanced Mutidetector-Row Computed Tomography Imaging of Liver for Assessing Hypervascular Hepatocellular Carcinoma: Multicenter Prospective Study in 77 General Hospitals in Japan
    Ichikawa, Tomoaki
    Okada, Masahiro
    Kondo, Hiroshi
    Sou, Hironobu
    Murakami, Takamichi
    Kanematsu, Masayuki
    Yoshikawa, Shushi
    Shiosakai, Kazuhito
    Hayakawa, Akiko
    Awai, Kazuo
    Yoshimitsu, Kengo
    Yamashita, Yasuyuki
    ACADEMIC RADIOLOGY, 2013, 20 (09) : 1130 - 1136
  • [38] Prospective study of computed tomography in patients with suspected acute appendicitis and low Alvarado score
    Wang, Shang-Yu
    Fang, Jen-Feng
    Liao, Chien-Hung
    Kuo, I-Ming
    Yang, Chun-Hsiang Ou
    Yeh, Chun-Nan
    Hsu, Yu-Pao
    Wong, Yon-Choeng
    Chiu, Te-Fa
    Yang, Shang-Ju
    AMERICAN JOURNAL OF EMERGENCY MEDICINE, 2012, 30 (08) : 1597 - 1601
  • [39] Optimizing Pulmonary Embolism Computed Tomography in the Age of Individualized Medicine A Prospective Clinical Study
    Hendriks, Babs M. F.
    Eijsvoogel, Nienke G.
    Kok, Madeleine
    Martens, Bibi
    Wildberger, Joachim E.
    Das, Marco
    INVESTIGATIVE RADIOLOGY, 2018, 53 (05) : 306 - 312
  • [40] Value of two-phase dynamic multidetector computed tomography in differential diagnosis of post-inflammatory strictures from esophageal cancer
    Karmazanovsky, Grigory G.
    Buryakina, Svetlana A.
    Kondratiev, Evgeny V.
    Yang, Qin
    Ruchkin, Dmitry V.
    Kalinin, Dmitry V.
    WORLD JOURNAL OF GASTROENTEROLOGY, 2015, 21 (29) : 8878 - 8887