Stability of halocarbons in air samples stored in stainless-steel canisters

被引:2
|
作者
Schuck, Tanja J. [1 ]
Blank, Ann-Katrin [1 ]
Rittmeier, Elisa [1 ]
Williams, Jonathan [2 ]
Brenninkmeijer, Carl A. M. [2 ]
Engel, Andreas [1 ]
Zahn, Andreas [3 ]
机构
[1] Goethe Univ Frankfurt, Inst Atmospher & Environm Sci, Frankfurt, Germany
[2] Max Planck Inst Chem, Mainz, Germany
[3] Karlsruhe Inst Technol, Inst Meteorol & Climate Res, Karlsruhe, Germany
关键词
VOLATILE ORGANIC-COMPOUNDS; LONG-TERM TRENDS; AIRCRAFT; ATMOSPHERE; EMISSIONS; SYSTEM; ONBOARD; ABOARD; GASES;
D O I
10.5194/amt-13-73-2020
中图分类号
P4 [大气科学(气象学)];
学科分类号
0706 ; 070601 ;
摘要
Measurements of halogenated trace gases in ambient air frequently rely on canister sampling followed by offline laboratory analysis. This allows for a large number of compounds to be analysed under stable conditions, maximizing measurement precision. However, individual compounds might be affected during the sampling and storage of canister samples. In order to assess halocarbon stability in whole-air samples from the upper troposphere and lowermost stratosphere, we performed stability tests using the high-resolution sampler (HIRES) air sampling unit, which is part of the Civil Aircraft for the Regular Investigation of the atmosphere Based on an Instrument Container (CARIBIC) instrument package. The HIRES unit holds 88 lightweight stainless-steel cylinders that are pressurized in flight to 4.5 bar using metal bellows pumps. The HIRES unit was first deployed in 2010 but has up to now not been used for regular halocarbon analysis with the exception of chloromethane analysis. The sample collection unit was tested for the sampling and storage effects of 28 halogenated compounds. The focus was on compound stability in the stainless-steel canisters during storage of up to 5 weeks and on the influence of ozone, since flights take place in the upper troposphere and lowermost stratosphere with ozone mixing ratios of up to several hundred parts per billion by volume (ppbv). Most of the investigated (hydro)chlorofluorocarbons and long-lived hydrofluorocarbons were found to be stable over a storage time of up to 5 weeks and were unaltered by ozone being present during pressurization. Some compounds such as dichloromethane, trichloromethane, and tetrachloroethene started to decrease in the canisters after a storage time of more than 2 weeks or exhibited lowered mixing ratios in samples pressurized with ozone present. A few compounds such as tetrachloromethane and tribromomethane were found to be unstable in the HIRES stainless-steel canisters independent of ozone levels. Furthermore, growth was observed during storage for some species, namely for HFC-152a, HFC-23, and Halon 1301.
引用
收藏
页码:73 / 84
页数:12
相关论文
共 50 条
  • [21] MICROPIERCING ON STAINLESS-STEEL
    WAKABAYASHI, K
    ONISHI, A
    MASUZAWA, T
    BULLETIN OF THE JAPAN SOCIETY OF PRECISION ENGINEERING, 1990, 24 (04): : 277 - 278
  • [22] STAINLESS-STEEL FAILURE
    不详
    CHEMTECH, 1975, (SEP) : 519 - 519
  • [23] STAINLESS-STEEL PIPING
    TUTHILL, AH
    JOURNAL AMERICAN WATER WORKS ASSOCIATION, 1994, 86 (07): : 67 - 73
  • [24] PENSTOCKS IN STAINLESS-STEEL
    不详
    WATER SERVICES, 1985, 89 (1071): : 215 - 215
  • [25] STAINLESS-STEEL REINFORCEMENT
    HAYNES, JM
    CIVIL ENGINEERING-LONDON, 1984, (AUG): : 23 - &
  • [26] STAINLESS-STEEL EXHAUSTS
    不详
    ANTI-CORROSION METHODS AND MATERIALS, 1972, 19 (10) : 16 - &
  • [27] DEOXIDIZING STAINLESS-STEEL
    BORRUSO, M
    PLATING AND SURFACE FINISHING, 1994, 81 (07): : 36 - 36
  • [28] COMPARISON OF ENDURANCE IN AIR AND IN WATER FOR A MARAGING-STEEL AND A MARTENSITIC STAINLESS-STEEL
    LELEU, G
    LIEURADE, HP
    POMEY, G
    RABBE, P
    THIVELLI.D
    WALDURA, H
    MEMOIRES SCIENTIFIQUES DE LA REVUE DE METALLURGIE, 1974, 71 (03): : 153 - 168
  • [29] STAINLESS-STEEL WELDING
    POLGARY, S
    METAL CONSTRUCTION, 1976, 8 (10): : 444 - &
  • [30] STAINLESS-STEEL IN TRANSPORT
    OGLE, AD
    ANTI-CORROSION METHODS AND MATERIALS, 1973, 20 (02) : 3 - 7