Evaluation of volumetric modulated arc therapy technique for cranio-spinal irradiation: A rando - phantom based dosimetric study

被引:2
作者
Goksel, E. O. [1 ]
Tezcanli, E. [2 ]
Okutan, M. [3 ]
Bilge, H. [3 ]
Yarar, Y. Yildiz [4 ]
机构
[1] Acibadem Mehmet Ali Aydinlar Univ, Vocat Sch Hlth Serv, Radiotherapy Program, Istanbul, Turkey
[2] Acibadem Altunizade Hosp, Dept Radiat Oncol, Istanbul, Turkey
[3] Istanbul Univ, Med Fac, Oncol Inst, Dept Radiotherapy, Istanbul, Turkey
[4] Yildiz Tech Univ, Dept Phys, Istanbul, Turkey
来源
INTERNATIONAL JOURNAL OF RADIATION RESEARCH | 2021年 / 19卷 / 03期
关键词
Cranio-spinal irradiation; VMAT; TLD; RANDO phantom; RADIATION-THERAPY; DOSE DISTRIBUTION; RADIOTHERAPY; PHOTON; IMRT; ALGORITHM; CANCER; SUPINE; RISK; VERIFICATION;
D O I
10.18869/acadpub.ijrr.19.3.531
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Background: In this study, clinical advantages and the dosimetric accuracy of volumetric modulated arc therapy (VMAT) technique for cranio-spinal irradiation (CSI) were investigated and compared with field in field (FinF) and intensity modulated radiotherapy (IMRT) techniques. Materials and Methods: The organs at risk (OARs) and planning target volume (PTV) were generated on the RANDO phantom computerized tomography (CT) image series. The dose-volume parameters for PTVs and OARs were compared for three techniques. Furthermore, the dose distribution inside the RANDO phantom was measured with thermoluminescent dosimeter (TLD) for all three techniques. Comparisons were done between measured and calculated doses of field junctions, targets and OARs. Results: FinF failed to obtain an adequate dose distribution for the upper spine (US), while VMAT and IMRT provided good dose coverage for all parts of the PTV. The most homogeneous dose distribution at the field junctions was obtained with the VMAT. Although heart, thyroid, intestine, lung, liver and testicular maximum doses were lower for the VMAT, the mean doses were higher except for the heart and thyroid. The absolute volume receiving prescription dose was significantly lower for the VMAT. The median differences between the TLD measurements and TPS calculations were 0.27% (7.8, -9.7; p=0.394), -0.28% (8.1, -10.7; p=0.322) and 0.33% (8.4, -12; p=0.338) for the FinF, IMRT and VMAT, respectively. These differences were not found statistically significant for the VMAT technique, as were the other two techniques. Conclusion: We conclude that the VMAT technique is the optimal Linac based CSI treatment in regards to dose coverage, dose homogeneity in field junctions and OAR sparing for higher doses. In addition, the VMAT showed dose distribution accuracy as good as the two other techniques in measurements simulating real clinical situations.
引用
收藏
页码:531 / 541
页数:11
相关论文
共 50 条
[31]   IMPACT OF VOLUMETRIC MODULATED ARC THERAPY TECHNIQUE ON TREATMENT WITH PARTIAL BREAST IRRADIATION [J].
Qiu, Jian-Jian ;
Chang, Zheng ;
Wu, Q. Jackie ;
Yoo, Sua ;
Horton, Janet ;
Yin, Fang-Fang .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2010, 78 (01) :288-296
[32]   Robustness of Breast Margins with Volumetric Modulated Arc Therapy without a Six-Degrees-of-Freedom Couch: A Dosimetric Evaluation [J].
Prunaretty, Jessica ;
Mir, Nicolas ;
Tilhac, Anais ;
Gouillou, Maureen ;
Azria, David ;
Fenoglietto, Pascal ;
Bourgier, Celine .
JOURNAL OF CLINICAL MEDICINE, 2023, 12 (03)
[33]   Feasibility study of multi-purpose quality assurance phantom for pretreatment verification of volumetric modulated arc therapy [J].
Won, H. S. ;
Chung, J. B. ;
Eom, K. Y. ;
Hwang, D. G. ;
Kang, S. W. ;
Suh, T. S. .
INTERNATIONAL JOURNAL OF RADIATION RESEARCH, 2018, 16 (03) :279-287
[34]   Dosimetric study of uniform scanning proton therapy planning for prostate cancer patients with a metal hip prosthesis, and comparison with volumetric-modulated arc therapy [J].
Rana, Suresh ;
Cheng, ChihYao ;
Zheng, Yuanshui ;
Hsi, Wen ;
Zeidan, Omar ;
Schreuder, Niek ;
Vargas, Carlos ;
Larson, Gary .
JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2014, 15 (03) :335-348
[35]   Dosimetric and radiobiological evaluation of stereotactic radiosurgery using volumetric modulated arc therapy and dynamic conformal arc therapy for multiple brain metastases [J].
Jiang, Chen-Jun ;
Ho, Yick-Wing ;
Lok, Ka-Hei ;
Lu, Yeow-Yuen ;
Zhu, Chun-Ran ;
Cheng, Harry Chi-Yuen .
SCIENTIFIC REPORTS, 2025, 15 (01)
[36]   Dosimetric comparison between volumetric-modulated arc therapy and a hybrid volumetric-modulated arc therapy and segmented field-in-field technique for postmastectomy chest wall and regional lymph node irradiation [J].
Lang, Karen ;
Loritz, Brianne ;
Schwartz, Adam ;
Hunzeker, Ashley ;
Lenards, Nishele ;
Culp, Lee ;
Finley, Randi ;
Corbin, Kimberly S. .
MEDICAL DOSIMETRY, 2020, 45 (02) :121-127
[37]   Evaluation of abches and volumetric modulated arc therapy under deep inspiration breath-hold technique for patients with left-sided breast cancer A retrospective observational study [J].
Yeh, Tien-Chi ;
Chi, Mau-Shin ;
Chi, Kwan-Hwa ;
Hsu, Chung-Hsien .
MEDICINE, 2019, 98 (39)
[38]   Volumetric modulated arc therapy for synchronous bilateral whole breast irradiation - A case study [J].
Seppala, Jan ;
Heikkila, Janne ;
Myllyoja, Kimmo ;
Koskela, Kristiina .
REPORTS OF PRACTICAL ONCOLOGY AND RADIOTHERAPY, 2015, 20 (05) :398-402
[39]   CBCT-based volumetric and dosimetric variation evaluation of volumetric modulated arc radiotherapy in the treatment of nasopharyngeal cancer patients [J].
Jin, Xiance ;
Hu, Weigang ;
Shang, Haijiao ;
Han, Ce ;
Yi, Jinling ;
Zhou, Yongqiang ;
Xie, Congying .
RADIATION ONCOLOGY, 2013, 8
[40]   Clinical impact of dosimetric changes for volumetric modulated arc therapy in log file-based patient dose calculations [J].
Katsuta, Yoshiyuki ;
Kadoya, Noriyuki ;
Fujita, Yukio ;
Shimizu, Eiji ;
Matsunaga, Kenichi ;
Matsushita, Haruo ;
Majima, Kazuhiro ;
Jingu, Keiichi .
PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2017, 42 :1-6