Evaluation of volumetric modulated arc therapy technique for cranio-spinal irradiation: A rando - phantom based dosimetric study

被引:2
作者
Goksel, E. O. [1 ]
Tezcanli, E. [2 ]
Okutan, M. [3 ]
Bilge, H. [3 ]
Yarar, Y. Yildiz [4 ]
机构
[1] Acibadem Mehmet Ali Aydinlar Univ, Vocat Sch Hlth Serv, Radiotherapy Program, Istanbul, Turkey
[2] Acibadem Altunizade Hosp, Dept Radiat Oncol, Istanbul, Turkey
[3] Istanbul Univ, Med Fac, Oncol Inst, Dept Radiotherapy, Istanbul, Turkey
[4] Yildiz Tech Univ, Dept Phys, Istanbul, Turkey
来源
INTERNATIONAL JOURNAL OF RADIATION RESEARCH | 2021年 / 19卷 / 03期
关键词
Cranio-spinal irradiation; VMAT; TLD; RANDO phantom; RADIATION-THERAPY; DOSE DISTRIBUTION; RADIOTHERAPY; PHOTON; IMRT; ALGORITHM; CANCER; SUPINE; RISK; VERIFICATION;
D O I
10.18869/acadpub.ijrr.19.3.531
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Background: In this study, clinical advantages and the dosimetric accuracy of volumetric modulated arc therapy (VMAT) technique for cranio-spinal irradiation (CSI) were investigated and compared with field in field (FinF) and intensity modulated radiotherapy (IMRT) techniques. Materials and Methods: The organs at risk (OARs) and planning target volume (PTV) were generated on the RANDO phantom computerized tomography (CT) image series. The dose-volume parameters for PTVs and OARs were compared for three techniques. Furthermore, the dose distribution inside the RANDO phantom was measured with thermoluminescent dosimeter (TLD) for all three techniques. Comparisons were done between measured and calculated doses of field junctions, targets and OARs. Results: FinF failed to obtain an adequate dose distribution for the upper spine (US), while VMAT and IMRT provided good dose coverage for all parts of the PTV. The most homogeneous dose distribution at the field junctions was obtained with the VMAT. Although heart, thyroid, intestine, lung, liver and testicular maximum doses were lower for the VMAT, the mean doses were higher except for the heart and thyroid. The absolute volume receiving prescription dose was significantly lower for the VMAT. The median differences between the TLD measurements and TPS calculations were 0.27% (7.8, -9.7; p=0.394), -0.28% (8.1, -10.7; p=0.322) and 0.33% (8.4, -12; p=0.338) for the FinF, IMRT and VMAT, respectively. These differences were not found statistically significant for the VMAT technique, as were the other two techniques. Conclusion: We conclude that the VMAT technique is the optimal Linac based CSI treatment in regards to dose coverage, dose homogeneity in field junctions and OAR sparing for higher doses. In addition, the VMAT showed dose distribution accuracy as good as the two other techniques in measurements simulating real clinical situations.
引用
收藏
页码:531 / 541
页数:11
相关论文
共 50 条
[21]   Comparative dosimetric evaluation of hybrid volumetric modulated arc therapy techniques for oesophageal cancer: a treatment planning study [J].
Patil, Deepali ;
Zope, Mukesh Kumar ;
Saroj, Dinesh Kumar ;
Devi, Seema ;
Sinha, Dinesh Kumar ;
Singh, Devraj .
JOURNAL OF RADIOTHERAPY IN PRACTICE, 2025, 24
[22]   Hybrid volumetric modulated arc therapy for whole breast irradiation: a dosimetric comparison of different arc designs [J].
Velayudham Ramasubramanian ;
Karunakaran Balaji ;
Sitaraman Balaji Subramanian ;
Krishnamoorthi Sathiya ;
Moorthi Thirunavukarasu ;
Chandrasekaran Anu Radha .
La radiologia medica, 2019, 124 :546-554
[23]   Fully automated treatment planning of spinal metastases - A comparison to manual planning of Volumetric Modulated Arc Therapy for conventionally fractionated irradiation [J].
Buergy, Daniel ;
Sharfo, Abdul Wahab M. ;
Heijmen, Ben J. M. ;
Voet, Peter W. J. ;
Breedveld, Sebastiaan ;
Wenz, Frederik ;
Lohr, Frank ;
Stieler, Florian .
RADIATION ONCOLOGY, 2017, 12
[24]   Feasibility and Toxicity of Full-Body Volumetric Modulated Arc Therapy Technique for High-Dose Total Body Irradiation [J].
Keit, Emily ;
Liveringhouse, Casey ;
Figura, Nicholas ;
Weygand, Joseph ;
Sandoval, Maria L. ;
Garcia, Genevieve ;
Peters, Julia ;
Nieder, Michael ;
Faramand, Rawan ;
Khimani, Farhad ;
Kim, Sungjune ;
Robinson, Timothy J. ;
Johnstone, Peter A. S. ;
Penagaricano, Jose ;
Latifi, Kujtim .
TECHNOLOGY IN CANCER RESEARCH & TREATMENT, 2023, 22
[25]   The dosimetric significance of using 10 MV photons for volumetric modulated arc therapy for post-prostatectomy irradiation of the prostate bed [J].
Kleiner, Henry ;
Podgorsak, Matthew B. .
RADIOLOGY AND ONCOLOGY, 2016, 50 (02) :232-237
[26]   Evaluation of the dosimetric impact of heart function-based volumetric modulated arc therapy planning in patients with esophageal cancer [J].
Tanaka, Shohei ;
Kadoya, Noriyuki ;
Umezawa, Rei ;
Nemoto, Hikaru ;
Katsuta, Yoshiyuki ;
Ito, Kengo ;
Takeda, Ken ;
Jingu, Keiichi .
RADIOLOGICAL PHYSICS AND TECHNOLOGY, 2021, 14 (03) :279-287
[27]   Application of volumetric modulated arc therapy (VMAT) for craniospinal irradiation: Dosimetric analysis and clinical implementation [J].
Tuong, Pham Nguyen ;
Duy, Phan Canh ;
Van Thanh, Nguyen ;
Nguyen, Le Thanh ;
Thao, Mai Thi ;
Tai, Duong Thanh ;
Sandwall, Peter ;
Ashmeg, Sarah ;
Sulieman, Abdelmoneim ;
Chow, James C. L. .
RADIATION PHYSICS AND CHEMISTRY, 2025, 236
[28]   Bilateral Regional Nodal Irradiation Using Volumetric Modulated Arc Therapy: Dosimetric Analysis and Feasibility [J].
Bernstein, Michael B. ;
Walker, Katherine ;
Gillespie, Erin ;
Mueller, Boris ;
Cuaron, John ;
Xu, Amy ;
McCormick, Beryl ;
Khan, Atif ;
Cahlon, Oren ;
Powell, Simon ;
Braunstein, Lior Z. .
PRACTICAL RADIATION ONCOLOGY, 2022, 12 (03) :189-194
[29]   Total body irradiation with volumetric modulated arc therapy: Dosimetric data and first clinical experience [J].
Springer, Andreas ;
Hammer, Josef ;
Winkler, Erwin ;
Track, Christine ;
Huppert, Roswitha ;
Boehm, Alexandra ;
Kasparu, Hedwig ;
Weltermann, Ansgar ;
Aschauer, Gregor ;
Petzer, Andreas L. ;
Putz, Ernst ;
Altenburger, Alexander ;
Gruber, Rainer ;
Moser, Karin ;
Wiesauer, Karin ;
Geinitz, Hans .
RADIATION ONCOLOGY, 2016, 11
[30]   The dosimetric impact of trade-off optimization in high-quality Craniospinal Irradiation plans based on volumetric modulated arc therapy technique [J].
Biswal, Subhra S. ;
Sarkar, Biplab ;
Goyal, Monika ;
Ganesh, Tharmarnadar .
MEDICAL DOSIMETRY, 2025, 50 (01) :36-42