Approaches for calibration and validation of near-infrared optical methods for oxygenation monitoring

被引:12
作者
Hornberger, Christoph [1 ]
Wabnitz, Heidrun [2 ]
机构
[1] Wismar Univ Appl Sci, Fac Engn, D-23966 Wismar, Germany
[2] PTB, D-10587 Berlin, Germany
来源
BIOMEDICAL ENGINEERING-BIOMEDIZINISCHE TECHNIK | 2018年 / 63卷 / 05期
关键词
cerebral oximetry; desaturation studies; oxygenation monitoring; phantoms; pulse oximetry; tissue oximetry; PULSE OXIMETRY; CEREBRAL OXYGENATION; TISSUE; PERFORMANCE; SPECTROSCOPY; PHANTOMS; DEVICES; HYPOXIA;
D O I
10.1515/bmt-2017-0116
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Pulse oximetry for arterial oxygenation monitoring and tissue oximetry for monitoring of cerebral oxygenation or muscle oxygenation are based on quantitative in vivo diffuse optical spectroscopy. However, in both cases the information on absolute or relative concentration of human tissue constituents and especially on hemoglobin oxygenation can often not be retrieved by model-based analysis. An in vivo calibration against an accepted reference measurement can be a practical alternative. Pulse oximeters and most of commercial cerebral tissue oximeters rely on empirical calibration based on invasive controlled human desaturation studies. As invasive in vivo tests on healthy subjects are ethically disputable and should be limited to exceptional cases this calibration practice is unsatisfactory. We present the current status and problems of calibration and validation in pulse oximetry and cerebral tissue oximetry including the pros and cons of in vivo as well as in vitro methods. We emphasize various digital and physical phantom approaches and discuss the prospects of their application and possible further developments.
引用
收藏
页码:537 / 546
页数:10
相关论文
共 41 条
  • [1] In Vitro Performance of a Perfusion and Oxygenation Optical Sensor Using a Unique Liver Phantom
    Akl, Tony J.
    King, Travis J.
    Long, Ruiqi
    Ericson, M. Nance
    Wilson, Mark A.
    McShane, Michael J.
    Cote, Gerard L.
    [J]. OPTICAL DIAGNOSTICS AND SENSING XII: TOWARD POINT-OF-CARE DIAGNOSTICS AND DESIGN AND PERFORMANCE VALIDATION OF PHANTOMS USED IN CONJUNCTION WITH OPTICAL MEASUREMENT OF TISSUE IV, 2012, 8229
  • [2] PHOTON-MEASUREMENT DENSITY-FUNCTIONS .1. ANALYTICAL FORMS
    ARRIDGE, SR
    [J]. APPLIED OPTICS, 1995, 34 (31): : 7395 - 7409
  • [3] Maximizing the Laboratory Setting for Testing Devices and Understanding Statistical Output in Pulse Oximetry
    Batchelder, Paul B.
    Raley, Dena M.
    [J]. ANESTHESIA AND ANALGESIA, 2007, 105 : S85 - S94
  • [4] Effects of Acute, Profound Hypoxia on Healthy Humans: Implications for Safety of Tests Evaluating Pulse Oximetry or Tissue Oximetry Performance
    Bickler, Philip E.
    Feiner, John R.
    Lipnick, Michael S.
    Batchelder, Paul
    MacLeod, David B.
    Severinghaus, John W.
    [J]. ANESTHESIA AND ANALGESIA, 2017, 124 (01) : 146 - 153
  • [5] Factors Affecting the Performance of 5 Cerebral Oximeters During Hypoxia in Healthy Volunteers
    Bickler, Philip E.
    Feiner, John R.
    Rollins, Mark D.
    [J]. ANESTHESIA AND ANALGESIA, 2013, 117 (04) : 813 - 823
  • [6] Influence of the phase function in generalized diffuse reflectance models: review of current formalisms and novel observations
    Calabro, Katherine W.
    Bigio, Irving J.
    [J]. JOURNAL OF BIOMEDICAL OPTICS, 2014, 19 (07)
  • [7] Fabrication of a turbid optofluidic phantom device with tunable μα and μs′ to simulate cutaneous vascular perfusion
    Chen, Chen
    Ahmed, Midhat
    Haefner, Tom
    Klaempfl, Florian
    Stelzle, Florian
    Schmidt, Michael
    [J]. SCIENTIFIC REPORTS, 2016, 6
  • [8] RETRACTED: Digital phantoms generated by spectral and spatial light modulators (Retracted Article)
    Chon, Bonghwan
    Tokumasu, Fuyuki
    Lee, Ji Youn
    Allen, David W.
    Rice, Joseph P.
    Hwang, Jeeseong
    [J]. JOURNAL OF BIOMEDICAL OPTICS, 2015, 20 (12)
  • [9] Impact of Extracranial Contamination on Regional Cerebral Oxygen Saturation A Comparison of Three Cerebral Oximetty Technologies
    Davie, Sophie N.
    Grocott, Hilary P.
    [J]. ANESTHESIOLOGY, 2012, 116 (04) : 834 - 840
  • [10] In-vivo multilaboratory investigation of the optical properties of the human head
    Farina, Andrea
    Torricelli, Alessandro
    Bargigia, Ilaria
    Spinelli, Lorenzo
    Cubeddu, Rinaldo
    Foschum, Florian
    Jaeger, Marion
    Simon, Emanuel
    Fugger, Oliver
    Kienle, Alwin
    Martelli, Fabrizio
    Di Ninni, Paola
    Zaccanti, Giovanni
    Milej, Daniel
    Sawosz, Piotr
    Kacprzak, Michal
    Liebert, Adam
    Pifferi, Antonio
    [J]. BIOMEDICAL OPTICS EXPRESS, 2015, 6 (07): : 2609 - 2623