Validation of a 3D computational fluid-structure interaction model simulating flow through an elastic aperture

被引:19
|
作者
Quaini, A. [1 ]
Canic, S. [1 ]
Glowinski, R. [1 ]
Igo, S. [2 ]
Hartley, C. J. [3 ]
Zoghbi, W. [2 ]
Little, S. [2 ]
机构
[1] Univ Houston, Dept Math, Houston, TX 77204 USA
[2] Methodist DeBakey Heart & Vasc Ctr, Dept Cardiol, Houston, TX USA
[3] Baylor Coll Med, Dept Med, Houston, TX 77030 USA
基金
美国国家科学基金会;
关键词
Fluid-structure interaction; Mitral valve regurgitation; Echocardiography; Computational fluid dynamics; Circulatory flow loop; FICTITIOUS DOMAIN METHOD; MECHANICAL HEART-VALVE; SPACE-TIME PROCEDURE; BLOOD-FLOW; MOVING BOUNDARIES; AORTIC-VALVE; INTERFACES; ARTERIES; REGURGITATION; FORMULATION;
D O I
10.1016/j.jbiomech.2011.10.020
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
This work presents a validation of a fluid-structure interaction computational model simulating the flow conditions in an in vitro mock heart chamber modeling mitral valve regurgitation during the ejection phase during which the trans-valvular pressure drop and valve displacement are not as large. The mock heart chamber was developed to study the use of 2D and 3D color Doppler techniques in imaging the clinically relevant complex intra-cardiac flow events associated with mitral regurgitation. Computational models are expected to play an important role in supporting, refining, and reinforcing the emerging 3D echocardiographic applications. We have developed a 3D computational fluid-structure interaction algorithm based on a semi-implicit, monolithic method, combined with an arbitrary Lagrangian-Eulerian approach to capture the fluid domain motion. The mock regurgitant mitral valve corresponding to an elastic plate with a geometric orifice, was modeled using 3D elasticity, while the blood flow was modeled using the 3D Navier-Stokes equations for an incompressible, viscous fluid. The two are coupled via the kinematic and dynamic conditions describing the two-way coupling. The pressure, the flow rate, and orifice plate displacement were measured and compared with numerical simulation results. In-line flow meter was used to measure the flow, pressure transducers were used to measure the pressure, and a Doppler method developed by one of the authors was used to measure the axial displacement of the orifice plate. The maximum recorded difference between experiment and numerical simulation for the flow rate was 4%, the pressure 3.6%, and for the orifice displacement 15%, showing excellent agreement between the two. (C) 2011 Elsevier Ltd. All rights reserved.
引用
收藏
页码:310 / 318
页数:9
相关论文
共 50 条
  • [41] 3D numerical simulation on fluid-structure interaction of structure subjected to underwater explosion with cavitation
    Zhang, A-man
    Ren, Shao-fei
    Li, Qing
    Li, Jia
    APPLIED MATHEMATICS AND MECHANICS-ENGLISH EDITION, 2012, 33 (09) : 1191 - 1206
  • [42] 3D numerical simulation on fluid-structure interaction of structure subjected to underwater explosion with cavitation
    A-man Zhang
    Shao-fei Ren
    Qing Li
    Jia Li
    Applied Mathematics and Mechanics, 2012, 33 : 1191 - 1206
  • [43] Identification of artery wall stiffness: In vitro validation and in vivo results of a data assimilation procedure applied to a 3D fluid-structure interaction model
    Bertoglio, Cristobal
    Barber, David
    Gaddum, Nicholas
    Valverde, Israel
    Rutten, Marcel
    Beerbaum, Philipp
    Moireau, Philippe
    Hose, Rodney
    Gerbeau, Jean-Frederic
    JOURNAL OF BIOMECHANICS, 2014, 47 (05) : 1027 - 1034
  • [44] 3D numerical simulation on fluid-structure interaction of structure subjected to underwater explosion with cavitation
    张阿漫
    任少飞
    李青
    李佳
    Applied Mathematics and Mechanics(English Edition), 2012, 33 (09) : 1191 - 1206
  • [45] Scalability study of an implicit solver for coupled fluid-structure interaction problems on unstructured meshes in 3D
    Kong, Fande
    Cai, Xiao-Chuan
    INTERNATIONAL JOURNAL OF HIGH PERFORMANCE COMPUTING APPLICATIONS, 2018, 32 (02) : 207 - 219
  • [46] A two-dimensional effective model describing fluid-structure interaction in blood flow: analysis, simulation and experimental validation
    Canic, S
    Mikelic, A
    Tambaca, J
    COMPTES RENDUS MECANIQUE, 2005, 333 (12): : 867 - 883
  • [47] Investigation of Fluid-Structure Interaction Induced Bending for Elastic Flaps in a Cross Flow
    Bano, Tayyaba
    Hegner, Franziska
    Heinrich, Martin
    Schwarze, Ruediger
    APPLIED SCIENCES-BASEL, 2020, 10 (18):
  • [48] Validation of a numerical 3-D fluid-structure interaction model for a prosthetic valve based on experimental PIV measurements
    Guivier-Curien, Carine
    Deplano, Valerie
    Bertrand, Eric
    MEDICAL ENGINEERING & PHYSICS, 2009, 31 (08) : 986 - 993
  • [49] Fluid-structure interaction modeling on a 3D ray-strengthened caudal fin
    Shi, Guangyu
    Xiao, Qing
    Zhu, Qiang
    Liao, Wei
    BIOINSPIRATION & BIOMIMETICS, 2019, 14 (03)
  • [50] FLUID-STRUCTURE INTERACTION MODELING AND VALIDATION OF IDEALIZED LEFT VENTRICULAR BLOOD FLOW
    Laughlin, Megan
    Stephens, Sam
    Jensen, Hanna
    Jensen, Morten
    Millett, Paul
    PROCEEDINGS OF THE ASME 2020 FLUIDS ENGINEERING DIVISION SUMMER MEETING (FEDSM2020), VOL 3, 2020,