Split-face randomized treatment of facial telangiectasia comparing pulsed dye laser and an intense pulsed light handpiece

被引:52
作者
Tanghetti, Emil A. [1 ]
机构
[1] Ctr Dermatol & Laser Surg, Sacramento, CA 95819 USA
关键词
intense pulsed-light; vascular lesions; pulsed dye laser; PORT-WINE STAINS; ABSORPTION; DURATION; IMPROVE; NM;
D O I
10.1002/lsm.21151
中图分类号
R75 [皮肤病学与性病学];
学科分类号
100206 ;
摘要
Background and Objective Facial telangiectasia and other vascular lesions have historically been effectively treated with the pulsed dye laser (PDL). This study compares the safety and efficacy of the PDL to an intense pulsed-light (IPL) handpiece with dual-band spectral absorption, shorter pulse widths, and constant output power. Study Design/Materials and Methods: Sixteen subjects were enrolled with facial telangiectasia in this single- site study. Subjects were randomized to receive up to two split-face treatments 1 month apart with PDL on one side and IPL on the other. PDL treatments were performed at 595 nm with either a 10 or 7 mm spot at a fluence range of 8.1-14.5 J/cm(2), and either 10 or 40 m seconds pulse width. Zimmer air cooling (setting of 4) and ultrasound gel were used for patient comfort. IPL treatments were performed with a spectral range of 500-670 and 870-1,200 nm, a 10 mm x 15 mm spot, fluence range of 34-70 J/cm(2), either a 10 or 100 mseconds pulse width, and 5 degrees C contact cooling. Safety assessments were conducted by the study investigator immediately, 4896 hours and 1-2 months post-treatment. Independent, blinded-review assessments were conducted 3 months post-treatment. Efficacy was evaluated using a seven-point Telangiectasia Grading Scale (TGS: 1 to 5). Subject self-assessment data were also collected. Results: The difference in incidence rate and severity of adverse side effects between the two devices were not statistically significant (P >= 0.39, Fisher's exact test) at any of the three evaluation periods. Per blinded-review assessment, the mean TGS score for both devices was 3.3 (IPL 95% CI: 2.8-3.7; PDL 95% CI: 2.9-3.8). The difference in blinded-ratings for the two devices were not statistically significant (P 0.82, ANOVA for repeated measures). Conclusion: The IPL studied here successfully treated facial telangiectasia, resulting in equivalent safety and efficacy outcomes as compared to the PDL. Lasers Surg.Med. 44: 97-102, 2012. (C) 2011 Wiley Periodicals, Inc.
引用
收藏
页码:97 / 102
页数:6
相关论文
共 30 条
  • [21] Does pulse stacking improve the results of treatment with variable-pulse pulsed-dye lasers?
    Rohrer, TE
    Chatrath, V
    Iyengar, V
    [J]. DERMATOLOGIC SURGERY, 2004, 30 (02) : 163 - 167
  • [22] Ross EV, 2005, DERMATOL SURG, V31, P1188
  • [23] TREATMENT OF CHILDREN WITH PORT-WINE STAINS USING THE FLASHLAMP-PULSED TUNABLE DYE-LASER
    TAN, OT
    SHERWOOD, K
    GILCHREST, BA
    [J]. NEW ENGLAND JOURNAL OF MEDICINE, 1989, 320 (07) : 416 - 421
  • [24] The effects of pulse dye laser double-pass treatment intervals on depth of vessel coagulation
    Tanghetti, E
    Sherr, EA
    Sierra, R
    Mirkov, M
    [J]. LASERS IN SURGERY AND MEDICINE, 2006, 38 (01) : 16 - 21
  • [25] Tanghetti E, 2003, LASER SURG MED, V32, P274
  • [26] Tanghetti E, 2003, LASER SURG MED, V32, P95
  • [27] Tanghetti EA, 2006, LASER SURG MED, P21
  • [28] Tanghetti Emil, 2003, J Cosmet Laser Ther, V5, P71, DOI 10.1080/14769170310001249
  • [29] Tanghetti EA, 2011, LASER AND IPL TECHNOLOGY IN DERMATOLOGY AND AESTHETIC MEDICINE, P227, DOI 10.1007/978-3-642-03438-1_16
  • [30] Characterization of an Optimized Light Source and Comparison to Pulsed Dye Laser for Superficial and Deep Vessel Clearance
    Weiss, Robert A.
    Ross, E. Victor
    Tanghetti, Emil A.
    Vasily, David B.
    Childs, James J.
    Smirnov, Mikhail Z.
    Altshuler, Gregory B.
    [J]. LASERS IN SURGERY AND MEDICINE, 2011, 43 (02) : 92 - 98