Scatter analysis and correction for ultrafast X-ray tomography

被引:9
作者
Wagner, Michael [2 ]
Barthel, Frank [1 ]
Zalucky, Johannes [1 ]
Bieberle, Martina [2 ]
Hampel, Uwe [1 ,2 ]
机构
[1] Helmholtz Zentrum Dresden Rossendorf, Inst Fluid Dynam, D-01328 Dresden, Germany
[2] Tech Univ Dresden, AREVA Endowed Chair Imaging Techn Energy & Proc E, D-01062 Dresden, Germany
来源
PHILOSOPHICAL TRANSACTIONS OF THE ROYAL SOCIETY A-MATHEMATICAL PHYSICAL AND ENGINEERING SCIENCES | 2015年 / 373卷 / 2043期
关键词
X-ray tomography; scatter analysis; cupping artefacts; CORRECTION ALGORITHM; BUBBLE-SIZE; SIMULATION; CT; RADIATION;
D O I
10.1098/rsta.2014.0396
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
Ultrafast X-ray computed tomography (CT) is an imaging technique with high potential for the investigation of the hydrodynamics in multiphase flows. For correct determination of the phase distribution of such flows, a high accuracy of the reconstructed image data is essential. In X-ray CT, radiation scatter may cause disturbing artefacts. As the scattering is not considered in standard reconstruction algorithms, additional methods are necessary to correct the detector readings or to prevent the detection of scattered photons. In this paper, we present an analysis of the scattering background for the ultrafast X-ray CT imaging system ROFEX at the Helmholtz-Zentrum Dresden-Rossendorf and propose a correction technique based on collimation and deterministic simulation of first-order scattering.
引用
收藏
页数:9
相关论文
共 17 条
  • [11] X-ray scatter correction algorithm for cone beam CT imaging
    Ning, R
    Tang, XY
    Conover, D
    [J]. MEDICAL PHYSICS, 2004, 31 (05) : 1195 - 1202
  • [12] Efficient object scatter correction algorithm for third and fourth generation CT scanners
    Ohnesorge, B
    Flohr, T
    Klingenbeck-Regn, K
    [J]. EUROPEAN RADIOLOGY, 1999, 9 (03) : 563 - 569
  • [13] A beam stop based correction procedure for high spatial frequency scatter in industrial cone-beam X-ray CT
    Peterzol, A.
    Letang, J. M.
    Babot, D.
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 2008, 266 (18) : 4042 - 4054
  • [14] Bubble size measurement using wire-mesh sensors
    Prasser, HM
    Scholz, D
    Zippe, C
    [J]. FLOW MEASUREMENT AND INSTRUMENTATION, 2001, 12 (04) : 299 - 312
  • [15] Bubble Size and Radial Gas Hold-Up Distributions in a Slurry Bubble Column Using Ultrafast Electron Beam X-Ray Tomography
    Rabha, Swapna
    Schubert, Markus
    Wagner, Michael
    Lucas, Dirk
    Hampel, Uwe
    [J]. AICHE JOURNAL, 2013, 59 (05) : 1709 - 1722
  • [16] Tillack GR, 1997, REV PROG Q, V16, P309
  • [17] Scatter and veiling glare estimation based on sampled primary intensity
    Zhou, YF
    Mathur, T
    Molloi, S
    [J]. MEDICAL PHYSICS, 1999, 26 (11) : 2301 - 2310