Cardiac resynchronization therapy with His bundle pacing

被引:33
作者
Boczar, Krzysztof [1 ]
Slawuta, Agnieszka [2 ]
Zabek, Andrzej [1 ]
Debski, Maciej [1 ]
Vijayaraman, Pugazhendhi [3 ]
Gajek, Jacek [4 ]
Lelakowski, Jacek [1 ,5 ]
Malecka, Barbara [1 ,5 ]
机构
[1] John Paul 2 Hosp, Dept Electrocardiol, Krakow, Poland
[2] Klodzko Cty Hosp, Dept Cardiol, Klodzko, Poland
[3] Geisinger Commonwealth Sch Med, Geisinger Heart Inst, Wilkes Barre, PA USA
[4] Wroclaw Med Univ, Dept Clin Nursing, Wroclaw, Poland
[5] Jagiellonian Univ, Coll Med, Inst Cardiol, Krakow, Poland
来源
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY | 2019年 / 42卷 / 03期
关键词
atrial fibrillation; bundle branch block; cardiac resynchronization therapy; His bundle pacing; pacemaker; TASK-FORCE; EUROPEAN-SOCIETY; HEART-FAILURE; BRANCH BLOCK; ASSOCIATION; PERMANENT; GUIDELINES; ESC;
D O I
10.1111/pace.13611
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Aims A novel therapy offering cardiac resynchronization therapy (CRT) with an additional lead placed in His bundle has been reported in a few case reports and case series as improving the hemodynamical and clinical condition of patients with permanent atrial fibrillation (AF) in whom other therapeutic methods have not been successful. Methods Fourteen consecutive patients with permanent AF, heart failure (HF), bundle branch block (BBB) with QRS complex width >130 ms, and impaired left ventricular ejection fraction (LVEF) underwent implantation of implantable cardioverter defibrillator (ICD)/CRT systems with His bundle pacing (HBP). During the follow-up, we assessed the efficacy of ICD/CRT systems with HBP in HF treatment. Results The study cohort consisted of 14 patients with the mean age of 67.35 +/- 10 years. The mean duration of QRS was 159.2 +/- 28.6 ms, mean LVEF was 24.36 +/- 10.7%, and mean follow-up duration was 14.4 months. One patient died due to HF aggravation during the follow-up. In the remaining 13 patients, the mean LVEF significantly improved from 24% to 38%, P = 0.0015. The left ventricular end-diastolic dimension decreased from 72 mm to 59 mm, P < 0.001; left ventricular end-systolic dimension decreased from 59 mm to 47 mm, P = 0.0026. The mean QRS duration shortened from 159 ms to 128 ms, P = 0.016. The mean percentage of HBP reached 97%. As a result, 92.3% of patients demonstrated significant improvement in the New York Heart Association functional class, P Conclusion The use of atrial channel for HBP, choice of optimal ICD/CRT pacing configuration, and optimization of pharmacological therapy resulted in a substantial narrowing of QRS width and clinical improvement in left ventricular mechanical function during the follow-up.
引用
收藏
页码:374 / 380
页数:7
相关论文
共 21 条
[21]   Direct His bundle pacing preserves coronary perfusion compared with right ventricular apical pacing: a prospective, cross-over mid-term study [J].
Zanon, Francesco ;
Bacchiega, Enrico ;
Rampin, Lucia ;
Aggio, Sivio ;
Baracca, Enrico ;
Pastore, Gianni ;
Marotta, Tiziana ;
Corbucci, Giorgio ;
Roncon, Loris ;
Rubello, Domenico ;
Prinzen, Frits W. .
EUROPACE, 2008, 10 (05) :580-587