Indoor Air Pollution of Outdoor Origin: Mitigation Using Portable Air Cleaners in Singapore Office Building

被引:7
|
作者
Sultan, Zuraimi [1 ]
Li, Jiayu [2 ]
Pantelic, Jovan [3 ,4 ]
Schiavon, Stefano [2 ,5 ]
机构
[1] Natl Environm Agcy, Environm Hlth Inst, Singapore 138602, Singapore
[2] Berkeley Educ Alliance Res Singapore BEARS Ltd, Singapore 138602, Singapore
[3] Katholieke Univ Leuven, B-3000 Leuven, Belgium
[4] Well Living Lab Inc, Rochester, MN 55902 USA
[5] Univ Calif Berkeley, Ctr Built Environm, Berkeley, CA 94720 USA
基金
新加坡国家研究基金会;
关键词
Air pollution; Indoor particles; Portable air cleaners; Office buildings; ULTRAFINE PARTICLES; REMOVAL; EXPOSURE; PENETRATION; FILTERS; IMPACT; RATES;
D O I
10.4209/aaqr.220204
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Landscape fires in Indonesia and traffic pollution have been receiving increasing attention as sources of particulate matter (PM) in Singapore. Although mitigation measures to reduce PM levels using portable air cleaners (PACs) have been used in residential buildings, its application for office buildings is unknown. Using PAC, we demonstrated their potential for indoor particles removal in an office building and presented a method to evaluate their performance and estimate number of units to be deployed. Modelled and in-situ measured PAC effectiveness using up to twelve units was evaluated in three office sizes (30, 80 and 1490 m(3)). Measured effectiveness using indoor concentrations and indoor/outdoor ratios was obtained in a randomised intervention experimental design involving 3 weeks per location. Indoor particle concentration reductions in the three offices were dependent on particle size and confounded by variations in indoor emissions and outdoor levels resulting in low correlation and higher RMSE between modelled and measured effectiveness. PAC effectiveness computed using I/O ratios for removing UFP, PM2.5 and PM10 ranged 24-43%, 23-53% and 7-37% respectively. PAC has a higher in-situ effectiveness in small compared to larger spaces and the effectiveness is logarithmically dependent on the number of units deployed. We validated the use of our model to determine PAC effectiveness in the offices using up to eleven PACs (RMSE between modelled and measured data ranging from 3.9 to 6.6%). Lastly, we developed a design method to size the number of PAC needed for office buildings. The results from this study can be used for standards organization, policy makers and researchers interested in particle exposure reductions in large spaces.
引用
收藏
页数:17
相关论文
共 50 条
  • [1] AIR CLEANERS FOR INDOOR AIR-POLLUTION CONTROL
    VINER, AS
    RAMANATHAN, K
    HANLEY, JT
    SMITH, DD
    ENSOR, DS
    SPARKS, LE
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 1989, 198 : 32 - I&EC
  • [2] CONTROL OF RESPIRABLE PARTICLES IN INDOOR AIR WITH PORTABLE AIR CLEANERS
    OFFERMANN, FJ
    SEXTRO, RG
    FISK, WJ
    GRIMSRUD, DT
    NAZAROFF, WW
    NERO, AV
    REVZAN, KL
    YATER, J
    ATMOSPHERIC ENVIRONMENT, 1985, 19 (11) : 1761 - 1771
  • [3] THE EFFECTS OF VENTILATION, FILTRATION, AND OUTDOOR AIR ON THE COMPOSITION OF INDOOR AIR AT A TELEPHONE OFFICE BUILDING
    WESCHLER, CJ
    SHIELDS, HC
    ENVIRONMENT INTERNATIONAL, 1989, 15 (1-6) : 593 - 604
  • [4] PORTABLE INDOOR AIR CLEANERS - A COMPARISON OF CLEANING TECHNOLOGIES
    LEVETIN, E
    SHAUGHNESSY, R
    SUBLETTE, K
    JOURNAL OF ALLERGY AND CLINICAL IMMUNOLOGY, 1992, 89 (01) : 257 - 257
  • [5] Comprehensive Evaluation on the Removal Performance of Air Cleaners for Indoor Air Pollution
    Yang, Rancun
    Yin, Keke
    Xu, Peng
    Wu, Peipei
    2020 6TH INTERNATIONAL CONFERENCE ON ENERGY, ENVIRONMENT AND MATERIALS SCIENCE, 2020, 585
  • [6] MEASUREMENT AND IMPACT OF OUTDOOR AIR SUPPLIED TO INDIVIDUAL OFFICE BUILDING OCCUPANTS ON INDOOR AIR-QUALITY
    FARANT, JP
    GREAVES, D
    ROBB, R
    AMERICAN INDUSTRIAL HYGIENE ASSOCIATION JOURNAL, 1991, 52 (09): : 387 - 392
  • [7] EFFECTIVENESS OF PORTABLE INDOOR AIR CLEANERS - SENSORY TESTING RESULTS
    SHAUGHNESSY, RJ
    LEVETIN, E
    BLOCKER, J
    SUBLETTE, KL
    INDOOR AIR-INTERNATIONAL JOURNAL OF INDOOR AIR QUALITY AND CLIMATE, 1994, 4 (03): : 179 - 188
  • [8] Reductions in Indoor Air Pollutants with Use of Portable Indoor Air Cleaners: Demonstration of Effectiveness in an Urban Environment
    Kipen, H. M.
    Meng, Q.
    Black, K.
    Laumbach, R. J.
    Alimokhtari, S.
    AMERICAN JOURNAL OF RESPIRATORY AND CRITICAL CARE MEDICINE, 2018, 197
  • [9] Modeling indoor air pollution of outdoor origin in homes of SAPALDIA subjects in Switzerland
    Meier, Reto
    Schindler, Christian
    Eeftens, Marloes
    Aguilera, Inmaculada
    Ducret-Stich, Regina E.
    Ineichen, Alex
    Davey, Mark
    Phuleria, Harish C.
    Probst-Hensch, Nicole
    Tsai, Ming-Yi
    Kuenzli, Nino
    ENVIRONMENT INTERNATIONAL, 2015, 82 : 85 - 91
  • [10] INDOOR AND OUTDOOR AIR-POLLUTION IN THE HIMALAYAS
    DAVIDSON, CI
    LIN, SF
    OSBORN, JF
    PANDEY, MR
    RASMUSSEN, RA
    KHALIL, MAK
    ENVIRONMENTAL SCIENCE & TECHNOLOGY, 1986, 20 (06) : 561 - 567