Construction-conditioned rollback in total knee replacement: fluoroscopic results

被引:0
作者
Wachowski, Martin Michael [1 ]
Fiedler, Christoph [2 ,3 ]
Walde, Tim Alexander [1 ]
Balcarek, Peter [1 ]
Schuettrumpf, Jan Philipp [1 ]
Frosch, Stephan [1 ]
Frosch, Karl-Heinz [4 ]
Fanghaenel, Jochen [2 ,3 ]
Gezzi, Riccardo [2 ,3 ]
Kubein-Meesenburg, Dietmar [2 ,3 ]
Naegerl, Hans [2 ,3 ]
机构
[1] Univ Gottingen, Dept Trauma Surg Plast & Reconstruct Surg, D-37075 Gottingen, Germany
[2] Univ Gottingen, Joint Biomech Working Grp Gottingen Greifswald, Dept Orthodont, D-37075 Gottingen, Germany
[3] Ernst Moritz Arndt Univ Greifswald, Dept Oral Anat, D-17487 Greifswald, Germany
[4] Asklepios Clin St Georg, Dept Trauma & Reconstruct Surg, Hamburg, Germany
关键词
total knee replacement; kinematic profile; rollback; roll-back fluoroscopy; patella tendon angle; kinematics; knee; JOINT; FEMUR;
D O I
暂无
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
Firstly, the way of implementing approximatively the initial rollback of the natural tibiofemoral joint (TFJ) in a total knee replacement (AEQUOS G1 TKR) is discussed. By configuration of the curvatures of the medial and lateral articulating surfaces a cam gear mechanism with positive drive can be installed, which works under force closure of the femoral and tibial surfaces. Briefly the geometric design features in flexion/extension are described and construction-conditioned kinematical and functional properties that arise are discussed. Due to a positive drive of the cam gear under the force closure during the stance phase of gait the articulating surfaces predominantly roll. As a result of rolling, a sliding friction is avoided, thus the resistance to motion is reduced during the stance phase. Secondly, in vivo fluoroscopic measurements of the patella tendon angle during flexion/extension are presented. The patella tendon angle/knee flexion angle characteristic and the kinematic profile in trend were similar to those observed in the native knee during gait (0 degrees-60 degrees).
引用
收藏
页码:35 / 42
页数:8
相关论文
共 26 条
[1]  
Beyer R., 1963, TECHNISCHE RAUMKINEM
[2]  
FISCHER O, 1907, KINEMATIK ORG GELENK, P189
[3]   Physiologically shaped knee arthroplasty induces natural roll-back [J].
Floerkemeier, Thilo ;
Frosch, Karl-Heinz ;
Wachowski, Martin ;
Kubein-Meesenburg, Dietmar ;
Gezzi, Riccardo ;
Fanghaenel, Jochen ;
Stuermer, Klaus Michael ;
Naegerl, Hans .
TECHNOLOGY AND HEALTH CARE, 2011, 19 (02) :91-102
[4]  
Frosch KH, 2009, UNFALLCHIRURG, V112, P176, DOI 10.1007/s00113-008-1551-4
[5]  
Frosch KH, 2009, UNFALLCHIRURG, V112, P168, DOI 10.1007/s00113-008-1550-5
[6]   Determination of the temperature rise within UHMWPE tibial components during tribological loading [J].
Galetz, Mathias C. ;
Uth, Tobias ;
Wimmer, Markus A. ;
Adam, Peter ;
Glatzel, Uwe .
ACTA BIOMATERIALIA, 2010, 6 (02) :552-562
[7]   Tibiofemoral movement 1: the shapes and relative movements of the femur and tibia in the unloaded cadaver knee [J].
Iwaki, H ;
Pinskerova, V ;
Freeman, MAR .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 2000, 82B (08) :1189-1195
[8]   INVIVO TRACKING OF THE HUMAN PATELLA [J].
KOH, TJ ;
GRABINER, MD ;
DESWART, RJ .
JOURNAL OF BIOMECHANICS, 1992, 25 (06) :637-&
[9]   CONTRIBUTION OF THE MUSCULATURE TO ROTATORY LAXITY AND TORSIONAL STIFFNESS AT THE KNEE [J].
LOUIE, JK ;
MOTE, CD .
JOURNAL OF BIOMECHANICS, 1987, 20 (03) :281-300
[10]   THE ROLE OF JOINT LOAD IN KNEE STABILITY [J].
MARKOLF, KL ;
BARGAR, WL ;
SHOEMAKER, SC ;
AMSTUTZ, HC .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1981, 63 (04) :570-585