Calcium Ions Turn on the Fluorescence of Oxytetracycline for Sensitive and Selective Detection

被引:23
|
作者
Chen, Hongxia [1 ]
Peng, Junxiang [1 ]
Yu, Long [1 ]
Chen, Hui [1 ]
Sun, Mingtai [3 ,4 ]
Sun, Zhenli [1 ]
Ni, Runyan [2 ,3 ,4 ]
Alamry, Khalid A. [5 ]
Marwani, Hadi M. [5 ]
Wang, Suhua [1 ,2 ,3 ,5 ]
机构
[1] North China Elect Power Univ, MOE Key Lab Resources & Environm Syst Optimizat, Coll Environm Sci & Engn, Beijing 102206, Peoples R China
[2] North China Elect Power Univ, Coll Environm Sci & Engn, Beijing 102206, Peoples R China
[3] Guangdong Univ Petrochem Technol, Sch Environm Sci & Engn, Guangdong Prov Key Lab Petrochemcial Pollut Proc, Maoming 525000, Peoples R China
[4] Natl Univ Singapore Suzhou Res Inst, 377 Linquan St, Suzhou 215123, Jiangsu, Peoples R China
[5] King Abdulaziz Univ, Fac Sci, Dept Chem, Jeddah 21589, Saudi Arabia
基金
中国国家自然科学基金;
关键词
Oxytetracycline (OTC); Fluorescent probe; Calcium ions; Calcium complex; Coordination; COMPLEXOMETRIC TITRATION; CARBON DOTS; TETRACYCLINE; CA2+; APTASENSOR; MAGNESIUM; ADSORPTION; INDICATOR; SENSOR; WASTE;
D O I
10.1007/s10895-020-02512-3
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Herein, we report an interesting finding about the new application of oxytetracycline (OTC), as a fluorescent probe for the detection of calcium ion (Ca2+), which proved that it can offer an expeditious, highly sensitive, and selective detection method for Ca2+. Upon the addition of Ca2+, the fluorescence of OTC could be significantly enhanced with rapid response and high sensitivity, and achieved a good limit of detection as low as 125 nM in aqueous solution. The complex formed via Ca2+ coordinating to the hydroxyl group of OTC contributes to the fluorescence enhancement, which has been proved by several characterization methods including UV-vis analysis, binding constant determination, and fluorescence titration. The method avoided complexity for EDTA measurement of Ca2+ in running water as proposed previously. Taking advantage of good availability, stability and operability, the OTC was further successfully applied to the detection of Ca2+ in a real environment. Graphical
引用
收藏
页码:463 / 470
页数:8
相关论文
共 50 条
  • [31] Highly Sensitive and Selective Fluorescence "Turn-On" Detection of Pb (II) Based on Fe3O4@Au-FITC Nanocomposite
    Cai, Yina
    Ren, Binxue
    Peng, Chifang
    Zhang, Cunzheng
    Wei, Xinlin
    MOLECULES, 2021, 26 (11):
  • [32] A sensitive fluorescence "turn on" nanosensor for glutathione detection based on Ce-MOF and gold nanoparticles
    Gong, Congcong
    Li, Zhijian
    Liu, Gang
    Wang, Renjie
    Pu, Shouzhi
    SPECTROCHIMICA ACTA PART A-MOLECULAR AND BIOMOLECULAR SPECTROSCOPY, 2022, 265
  • [33] A new sensitive and selective fluorescence probe for detection of cyanide
    Duan, Yi-Long
    Zheng, Yan-Song
    TALANTA, 2013, 107 : 332 - 337
  • [34] Selective and sensitive turn-on chemosensor for Al(III) ions applicable in living organisms: nanomolar detection in aqueous medium
    Pal, Siddhartha
    Sen, Buddhadeb
    Mukherjee, Manjira
    Patra, Mousumi
    Lahiri , Susmita
    Chattopadhyay, Pabitra
    RSC ADVANCES, 2015, 5 (89): : 72508 - 72514
  • [35] Sensitive and selective detection of zinc ions in neuronal vesicles using PYDPY1, a simple turn-on dipyrrin
    Mei, Yujiang
    Frederickson, Christopher J.
    Giblin, Leonard J.
    Weiss, John H.
    Medvedeva, Yuliya
    Bentley, Paul A.
    CHEMICAL COMMUNICATIONS, 2011, 47 (25) : 7107 - 7109
  • [36] Highly sensitive turn-on fluorescence detection of thrombomodulin based on fluorescence resonance energy transfer
    Kong, Liyan
    Zhu, Jiaming
    Wang, Wen
    Jin, Lehe
    Fu, Yanjiao
    Duan, Bohui
    Tan, Liang
    SPECTROCHIMICA ACTA PART A-MOLECULAR AND BIOMOLECULAR SPECTROSCOPY, 2017, 173 : 675 - 680
  • [37] A HOF-based electrochemical aptasensor for highly sensitive and selective detection of trace oxytetracycline
    Wang, Qian
    Li, Ping
    Wen, Hao-Ming
    Hu, Kai-Jie
    Huang, Zi-Yue
    Chen, Jing
    INORGANIC CHEMISTRY COMMUNICATIONS, 2023, 156
  • [38] Turn-off-on fluorescence probe based on 3-mercaptopropionic acid-capped CdS quantum dots for selective and sensitive lysozyme detection
    Liu, Xiaotong
    Na, Weidan
    Qu, Zhengyi
    Su, Xingguang
    RSC ADVANCES, 2016, 6 (89) : 85795 - 85801
  • [39] Water-ratio directed selective turn-on fluorescence detection of copper and mercury in acetonitrile
    Toprak, Mahmut
    Lafzi, Ferruh
    Bayindir, Sinan
    JOURNAL OF PHOTOCHEMISTRY AND PHOTOBIOLOGY A-CHEMISTRY, 2021, 418
  • [40] Highly selective and sensitive detection of calcium (II) ions in human serum using novel fluorescent carbon dots
    Ankireddy, Seshadri Reddy
    Kim, Jongsung
    SENSORS AND ACTUATORS B-CHEMICAL, 2018, 255 : 3425 - 3433