Calcium Ions Turn on the Fluorescence of Oxytetracycline for Sensitive and Selective Detection

被引:23
|
作者
Chen, Hongxia [1 ]
Peng, Junxiang [1 ]
Yu, Long [1 ]
Chen, Hui [1 ]
Sun, Mingtai [3 ,4 ]
Sun, Zhenli [1 ]
Ni, Runyan [2 ,3 ,4 ]
Alamry, Khalid A. [5 ]
Marwani, Hadi M. [5 ]
Wang, Suhua [1 ,2 ,3 ,5 ]
机构
[1] North China Elect Power Univ, MOE Key Lab Resources & Environm Syst Optimizat, Coll Environm Sci & Engn, Beijing 102206, Peoples R China
[2] North China Elect Power Univ, Coll Environm Sci & Engn, Beijing 102206, Peoples R China
[3] Guangdong Univ Petrochem Technol, Sch Environm Sci & Engn, Guangdong Prov Key Lab Petrochemcial Pollut Proc, Maoming 525000, Peoples R China
[4] Natl Univ Singapore Suzhou Res Inst, 377 Linquan St, Suzhou 215123, Jiangsu, Peoples R China
[5] King Abdulaziz Univ, Fac Sci, Dept Chem, Jeddah 21589, Saudi Arabia
基金
中国国家自然科学基金;
关键词
Oxytetracycline (OTC); Fluorescent probe; Calcium ions; Calcium complex; Coordination; COMPLEXOMETRIC TITRATION; CARBON DOTS; TETRACYCLINE; CA2+; APTASENSOR; MAGNESIUM; ADSORPTION; INDICATOR; SENSOR; WASTE;
D O I
10.1007/s10895-020-02512-3
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Herein, we report an interesting finding about the new application of oxytetracycline (OTC), as a fluorescent probe for the detection of calcium ion (Ca2+), which proved that it can offer an expeditious, highly sensitive, and selective detection method for Ca2+. Upon the addition of Ca2+, the fluorescence of OTC could be significantly enhanced with rapid response and high sensitivity, and achieved a good limit of detection as low as 125 nM in aqueous solution. The complex formed via Ca2+ coordinating to the hydroxyl group of OTC contributes to the fluorescence enhancement, which has been proved by several characterization methods including UV-vis analysis, binding constant determination, and fluorescence titration. The method avoided complexity for EDTA measurement of Ca2+ in running water as proposed previously. Taking advantage of good availability, stability and operability, the OTC was further successfully applied to the detection of Ca2+ in a real environment. Graphical
引用
收藏
页码:463 / 470
页数:8
相关论文
共 50 条
  • [21] Design of a Fluorescence-Enhanced Aptasensor for Sensitive Detection of Silver Ions
    Ren, L.
    Chen, G.
    Peng, Zh
    Xu, X.
    Zhang, P.
    Qin, Z.
    Chen, Q.
    Yan, Y.
    Jiang, L.
    JOURNAL OF APPLIED SPECTROSCOPY, 2022, 89 (05) : 984 - 991
  • [22] Green-emitting carbon dots as a “turn on” fluorescence bio-probe for highly sensitive and selective detection of lipase in human serum
    Haitham Saad Al-mashriqi
    Pascaline Sanga
    Jia Chen
    Xin Li
    Jing Xiao
    Yan Li
    Hongdeng Qiu
    Analytical and Bioanalytical Chemistry, 2024, 416 : 971 - 981
  • [23] Highly selective and sensitive coumarin-triazole-based fluorometric "turn-off' sensor for detection of Pb2+ ions
    Shaily
    Kumar, Ajay
    Parveen, Iram
    Ahmed, Naseem
    LUMINESCENCE, 2018, 33 (04) : 713 - 721
  • [24] κ-Carrageenan-derived carbon dots for highly selective and sensitive detection of Fe3+ and oxytetracycline
    Wang, Yesheng
    Liu, Yaoyang
    Zhao, Li
    Sun, Lili
    Zhao, Xihui
    Xia, Yanzhi
    JOURNAL OF MATERIALS SCIENCE, 2021, 56 (02) : 1272 - 1285
  • [25] Base on spectroscopic properties response fluorescence probe for rapid, sensitive and selective detection of aluminum ions in wastewater
    Lian, Guangchang
    Hu, Kaibo
    Wang, Yuling
    Shao, Tingyu
    Qi, Xueyong
    Zhou, Meng
    Liu, Ying
    Jin, Guofan
    INORGANIC CHEMISTRY COMMUNICATIONS, 2022, 137
  • [26] Highly selective and sensitive fluorescence turn-on probe for a catalytic amount of Cu(I) ions in water through the click reaction
    Park, Seokan
    Kim, Hae-Jo
    TETRAHEDRON LETTERS, 2012, 53 (33) : 4473 - 4475
  • [27] Highly Selective and Sensitive Luminescent Turn-On Probe for Pyrophosphate Detection in Aqueous Solution
    Zhang, Shi-Ting
    Li, Panpan
    Kou, Xingming
    Xiao, Dan
    CHEMISTRYSELECT, 2018, 3 (35): : 10057 - 10063
  • [28] Oligonucleotide-based fluorescence system for sensitive and selective detection of Ag(I) ions in aqueous solution
    Chen, Hui
    Wang, Dan
    He, Qizhi
    Li, Hua
    Ding, Xinghua
    Chen, Lingli
    Deng, Le
    WATER SCIENCE AND TECHNOLOGY, 2012, 65 (03) : 440 - 446
  • [29] A Turn-on Fluorescence Probe For Rapid, Sensitive And Visual Detection of Formaldehyde
    Cheng, Huan-ren
    Zou, Li-wei
    Yang, Ling
    Wang, Zhi-guo
    Lu, Xiao-ju
    CHEMISTRYSELECT, 2019, 4 (01): : 432 - 436
  • [30] Amide-decorated carbon dots as sensitive and selective probes for fluorescence enhancement detection of cadmium ion
    Tang, Lu
    Zhu, Chenxue
    Yang, Yingsang
    Luo, Jiajun
    Song, Jinhui
    Chen, Huimin
    Liu, Suyao
    Liu, Yi
    Fang, Yiwen
    SPECTROCHIMICA ACTA PART A-MOLECULAR AND BIOMOLECULAR SPECTROSCOPY, 2023, 303