A comparative study of different types of sandwiched structures of SPR biosensor for sensitive detection of ssDNA

被引:21
|
作者
Kumar, Awadhesh [1 ]
Kumar, Anil [1 ]
Kushwaha, Angad S. [2 ]
Dubey, Sarvesh K. [1 ]
Srivastava, S. K. [1 ]
机构
[1] Banaras Hindu Univ, Inst Sci, Dept Phys, Varanasi 221005, Uttar Pradesh, India
[2] Dayanand Ved Coll, Dept Phys, Jalaun 285001, Uttar Pradesh, India
关键词
Surface plasmon resonance (SPR); Sensitivity; Graphene; Biosensor; TMDCs; SsDNA; SURFACE-PLASMON RESONANCE; THIN-FILM; GRAPHENE; PERFORMANCE; DNA; WS2; ENHANCEMENT; SENSOR; MOS2; MONOLAYER;
D O I
10.1016/j.photonics.2021.100984
中图分类号
TB3 [工程材料学];
学科分类号
0805 ; 080502 ;
摘要
Graphene and other 2D materials have attracted many scientific communities due to excellent performance in the area of SPR biosensor. In this paper, we propose SPR biosensors for the detection of ssDNA using hybrid structure of different 2D materials in Kretschmann configuration. Further, we compare eight different types of configurations using silver (Ag), graphene, gold (Au) and transition metal dichalcogenides (TMDCs) in terms of various sensing performance parameters such as sensitivity (S), detection accuracy (D. A) and quality factor (Q. F). The schematic study of different configurations indicates that introduction of graphene, WS2 and MoS2 increase the sensing performances as compare to the conventional SPR biosensor. In our proposed structures, maximum sensitivity occurs for monolayer graphene, bilayer WS2 and monolayer MoS2 combination. In this case, maximum obtained sensitivity is 203 deg./RIU with detection accuracy 1.13 and quality factor 28.31 RIU-1. This analysis shows that heterostructure SPR biosensor with sandwiched graphene layer, consisting of bimetallic layers of TMDCs, enhances the sensing performance as compare to the other reported works which comprised of graphene and 2D materials. Therefore, our proposed SPR biosensor may have potential applications in medical diagnostic for biochemical detection and open a new dimension in the field of biosensing.
引用
收藏
页数:8
相关论文
共 50 条
  • [41] Development and comparative study of different immunoenzyme techniques for pesticides detection
    Dzantiev, BB
    Zherdev, AV
    Romanenko, OG
    Sapegova, LA
    INTERNATIONAL JOURNAL OF ENVIRONMENTAL ANALYTICAL CHEMISTRY, 1996, 65 (1-4) : 95 - 111
  • [42] An enhanced SPR optical fiber biosensor using Ti3C2Tx MXene/AuNPs for label-free and sensitive detection of human IgG
    Zhu, Jiayi
    Zhao, Chao
    Xia, Binyun
    Wang, Ning
    Chen, Xi
    Jing, Xinyue
    Chen, Minxuan
    Xu, Xinrui
    NANOSCALE, 2024, 16 (39) : 18477 - 18487
  • [43] A comparative study of different microchips for capillary electrophoresis with electrochemical detection
    Erro, Eustaquio M.
    Ortiz, Patricia I.
    JOURNAL OF APPLIED ELECTROCHEMISTRY, 2014, 44 (12) : 1393 - 1399
  • [44] Detection and quantification of HBV and HCV in plasma samples by means of different molecular assays: Comparative study
    Manso, Tamara
    de Salazar, Adolfo
    Rodriguez-Velasco, Maria
    Garcia, Federico
    Aguilera, Antonio
    ENFERMEDADES INFECCIOSAS Y MICROBIOLOGIA CLINICA, 2024, 42 (01): : 13 - 16
  • [45] Application of Modified MPPT Algorithms: A Comparative Study between Different Types of Solar Cells
    Khodair D.
    Salem M.S.
    Shaker A.
    El Munim H.E.A.
    Abouelatta M.
    Applied Solar Energy (English translation of Geliotekhnika), 2020, 56 (05): : 309 - 323
  • [46] Simple Strategy for Rapid and Sensitive Detection of Avian Influenza A H7N9 Virus Based on Intensity-Modulated SPR Biosensor and New Generated Antibody
    Chang, Ying-Feng
    Wang, Wen-Hung
    Hong, Yi-Wei
    Yuan, Ruei-Yu
    Chen, Kuan-Hsuan
    Huang, Yu-Wen
    Lu, Po-Liang
    Chen, Yen-Hsu
    Chen, Yi-Ming Arthur
    Su, Li-Chen
    Wang, Sheng-Fan
    ANALYTICAL CHEMISTRY, 2018, 90 (03) : 1861 - 1869
  • [47] A dual-fluorescence biosensor assembled by quantum dots and phenazinium dyes: A comparative study for DNA detection
    Wang, Linlin
    Liu, Shaopu
    Hao, Chenxia
    Zhang, Xiaolong
    Wang, Chaoqun
    He, Youqiu
    SENSORS AND ACTUATORS B-CHEMICAL, 2016, 229 : 145 - 154
  • [48] A comparative study of pool boiling heat transfer in different porous artery structures
    Zhang, Kai
    Bai, Lizhan
    Jin, Haichuan
    Lin, Guiping
    Yao, Guice
    Wen, Dongsheng
    APPLIED THERMAL ENGINEERING, 2022, 202
  • [49] Comparative study of the bond strength of ZirCAD Multi and ZirCAD Prime ceramics with different types of cements
    Gerdzhikov, Ivan
    Radeva, Elka
    Uzunov, Todor
    BIOTECHNOLOGY & BIOTECHNOLOGICAL EQUIPMENT, 2023, 37 (01)
  • [50] A comparative study of different types of reduced graphene oxides as electrochemical sensing platforms for hydroquinone and catechol
    Li, Su-Juan
    Xing, Yun
    Deng, De-Hua
    Shi, Meng-Meng
    Guan, Peng-Peng
    JOURNAL OF SOLID STATE ELECTROCHEMISTRY, 2015, 19 (03) : 861 - 870