Piecewise direct standardization assisted with second-order calibration methods to solve signal instability in high-performance liquid chromatography-diode array detection systems

被引:6
|
作者
Chen, Yue [1 ]
Wu, Hai-Long [1 ]
Wang, Tong [1 ]
Liu, Bing-Bing [1 ]
Ding, Yu-Jie [1 ]
Yu, Ru-Qin [1 ]
机构
[1] Hunan Univ, Coll Chem & Chem Engn, State Key Lab Chemo Biosensing & Chemometr, Changsha 410082, Hunan, Peoples R China
关键词
High performance liquid; chromatography-diode array detection; Alternating trilinear decomposition; Alternating trilinear decomposition assisted; multivariate curve resolution; Piecewise direct standardization; Signal instability; Second-order advantage; MULTIVARIATE CALIBRATION; HPLC-DAD; PESTICIDES; RESOLUTION; ADULTERATION; ALGORITHMS; ADVANTAGE;
D O I
10.1016/j.chroma.2022.462851
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
In this paper, in order to solve signal instability of high-performance liquid chromatography-diode array detection (HPLC-DAD) data and maintain the second-order advantage, this work proposed piecewise direct standardization (PDS) assisted with second-order calibration methods to analyze two different complex HPLC-DAD data with signal instability, including simulated HPLC-DAD data and the data of pesticide residues in saffron. Accurate quantitative results of target analytes can be obtained by PDS combined with alternating trilinear decomposition algorithm (ATLD) and alternating trilinear decomposition assisted multivariate curve resolution algorithm (ATLD-MCR) in the presence of signal instability with time shifts and changes of peak shape. Quantitative results of the model after calibration transfer are better than those of the model established by calibration sets and prediction sets with signal instability using ATLD algorithm and ATLD-MCR algorithm under different situations. Meanwhile, t-test was used to judge whether there are significant differences between these quantitative results of models. The performances of MCR-ALS algorithm were compared with that of PDS-ATLD method and PDS-ATLD-MCR method and the proposed methods have greater potential in dealing with the case of signal instability with time shifts and changes of peak shape. In a word, this methodology can reduce the number of calibration samples for recalibration and modeling, improve the efficiency of experiment, conform to the principle of green chemistry, and obtain satisfactory quantitative results in the presence of signal instability with time shifts and changes of peak shape. (c) 2022 Elsevier B.V. All rights reserved.
引用
收藏
页数:9
相关论文
共 50 条
  • [41] Simple quantification of endogenous retinoids in bovine serum by high-performance liquid chromatography - diode-array detection
    Van Merris, V
    Meyer, E
    De Wasch, K
    Burvenich, C
    ANALYTICA CHIMICA ACTA, 2002, 468 (02) : 237 - 244
  • [42] Determination of piperazine-type stimulants in human urine by means of microextraction in packed sorbent and high performance liquid chromatography-diode array detection
    Moreno, I. E. D.
    da Fonseca, B. M.
    Barroso, M.
    Costa, S.
    Queiroz, J. A.
    Gallardo, E.
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2012, 61 : 93 - 99
  • [43] Magnetic solid phase extraction coupled with high-performance liquid chromatography-diode array detection based on assembled magnetic covalent organic frameworks for selective extraction and detection of microcystins in aquatic foods
    Wang, Tianliang
    Xie, Hongzhen
    Cao, Yuting
    Xu, Qing
    Gan, Ning
    JOURNAL OF CHROMATOGRAPHY A, 2022, 1685
  • [44] Analysis of opiates, cocaine and metabolites in urine by high-performance liquid chromatography with diode array detection (HPLC-DAD)
    Fernández, P
    Vázquez, C
    Morales, L
    Bermejo, AM
    JOURNAL OF APPLIED TOXICOLOGY, 2005, 25 (03) : 200 - 204
  • [45] Simultaneous determination of phenols (bibenzyl, phenanthrene, and fluorenone) in Dendrobium species by high-performance liquid chromatography with diode array detection
    Yang, L
    Wang, ZT
    Xu, LS
    JOURNAL OF CHROMATOGRAPHY A, 2006, 1104 (1-2) : 230 - 237
  • [46] DETERMINATION OF LINEZOLID IN HUMAN SERUM BY REVERSED-PHASE HIGH-PERFORMANCE LIQUID CHROMATOGRAPHY WITH ULTRAVIOLET AND DIODE ARRAY DETECTION
    Cios, Agnieszka
    Kus, Kamil
    Szymura-Oleksiak, Joanna
    ACTA POLONIAE PHARMACEUTICA, 2013, 70 (04): : 631 - 641
  • [47] Simultaneous qualitation and quantification of four phytoecdysones in Radix Achyranthis Bidentatae by high-performance liquid chromatography with diode array detection
    Li, Juan
    Li, Hui-Jun
    Li, Ping
    Qi, Hui
    BIOMEDICAL CHROMATOGRAPHY, 2007, 21 (08) : 823 - 828
  • [48] Simultaneous determination of eight bioactive alkaloids in Corydalis saxicola by high-performance liquid chromatography coupled with diode array detection
    Cheng, Xuanxuan
    Wang, Dongmei
    Jiang, Lin
    Yang, Depo
    PHYTOCHEMICAL ANALYSIS, 2008, 19 (05) : 420 - 428
  • [49] Effect of temperature on the separation of chlorophenoxy acids and carbamates by capillary high-performance liquid chromatography and UV (or diode array) detection
    Rosales-Conrado, N
    León-González, ME
    Pérez-Arribas, LV
    Polo-Díez, LM
    JOURNAL OF CHROMATOGRAPHY A, 2005, 1081 (01) : 114 - 121
  • [50] Determination of fourteen polyphenols in pulses by high performance liquid chromatography-diode array detection (HPLC-DAD) and correlation study with antioxidant activity and colour
    Giusti, Federica
    Caprioli, Giovanni
    Ricciutelli, Massimo
    Vittori, Sauro
    Sagratini, Gianni
    FOOD CHEMISTRY, 2017, 221 : 689 - 697