Piecewise direct standardization assisted with second-order calibration methods to solve signal instability in high-performance liquid chromatography-diode array detection systems

被引:6
|
作者
Chen, Yue [1 ]
Wu, Hai-Long [1 ]
Wang, Tong [1 ]
Liu, Bing-Bing [1 ]
Ding, Yu-Jie [1 ]
Yu, Ru-Qin [1 ]
机构
[1] Hunan Univ, Coll Chem & Chem Engn, State Key Lab Chemo Biosensing & Chemometr, Changsha 410082, Hunan, Peoples R China
关键词
High performance liquid; chromatography-diode array detection; Alternating trilinear decomposition; Alternating trilinear decomposition assisted; multivariate curve resolution; Piecewise direct standardization; Signal instability; Second-order advantage; MULTIVARIATE CALIBRATION; HPLC-DAD; PESTICIDES; RESOLUTION; ADULTERATION; ALGORITHMS; ADVANTAGE;
D O I
10.1016/j.chroma.2022.462851
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
In this paper, in order to solve signal instability of high-performance liquid chromatography-diode array detection (HPLC-DAD) data and maintain the second-order advantage, this work proposed piecewise direct standardization (PDS) assisted with second-order calibration methods to analyze two different complex HPLC-DAD data with signal instability, including simulated HPLC-DAD data and the data of pesticide residues in saffron. Accurate quantitative results of target analytes can be obtained by PDS combined with alternating trilinear decomposition algorithm (ATLD) and alternating trilinear decomposition assisted multivariate curve resolution algorithm (ATLD-MCR) in the presence of signal instability with time shifts and changes of peak shape. Quantitative results of the model after calibration transfer are better than those of the model established by calibration sets and prediction sets with signal instability using ATLD algorithm and ATLD-MCR algorithm under different situations. Meanwhile, t-test was used to judge whether there are significant differences between these quantitative results of models. The performances of MCR-ALS algorithm were compared with that of PDS-ATLD method and PDS-ATLD-MCR method and the proposed methods have greater potential in dealing with the case of signal instability with time shifts and changes of peak shape. In a word, this methodology can reduce the number of calibration samples for recalibration and modeling, improve the efficiency of experiment, conform to the principle of green chemistry, and obtain satisfactory quantitative results in the presence of signal instability with time shifts and changes of peak shape. (c) 2022 Elsevier B.V. All rights reserved.
引用
收藏
页数:9
相关论文
共 50 条
  • [21] Comparison of three second-order multivariate calibration methods for the rapid identification and quantitative analysis of tea polyphenols in Chinese teas using high-performance liquid chromatography
    Zhang, Xiao-Hua
    Zhou, Qian
    Liu, Zhi
    Qing, Xiang-Dong
    Zheng, Jing-Jing
    Mu, Shu-Ting
    Liu, Pan-Hua
    JOURNAL OF CHROMATOGRAPHY A, 2020, 1618
  • [22] High-Performance Liquid Chromatography-Diode Array Detection Combined with Chemometrics for Simultaneous Quantitative Analysis of Five Active Constituents in a Chinese Medicine Formula Wen-Qing-Yin
    Chen, Jun-Chen
    Wu, Hai-Long
    Wang, Tong
    Dong, Ming-Yue
    Chen, Yue
    Yu, Ru-Qin
    CHEMOSENSORS, 2022, 10 (07)
  • [23] Determination of benzimidazole residues and their metabolites in raw milk using high performance liquid chromatography-diode array detection
    Lugomer, Marija Denzic
    Pavlicek, Damir
    Bilandzic, Nina
    Majnaric, Darko
    MLJEKARSTVO, 2017, 67 (03): : 231 - 238
  • [24] Development and validation of a High Performance Liquid Chromatography-Diode Array Detection method for the determination of aging markers in tequila
    Celia Munoz-Munoz, Ana
    Charles Grenier, Adam
    Gutierrez-Pulido, Humberto
    Cervantes-Martinez, Jesus
    JOURNAL OF CHROMATOGRAPHY A, 2008, 1213 (02) : 218 - 223
  • [25] Second-order bilinear calibration for determining polycyclic aromatic compounds in marine sediments by solvent extraction and liquid chromatography with diode-array detection
    Gimeno, RA
    Comas, E
    Marcé, RM
    Ferré, J
    Rius, FX
    Borrull, F
    ANALYTICA CHIMICA ACTA, 2003, 498 (1-2) : 47 - 53
  • [26] Trace determination of malachite green in water samples using dispersive liquid-liquid microextraction coupled with high-performance liquid chromatography-diode array detection
    Maleki, Ramin
    Farhadi, Khalil
    Nikkhahi, Yousef
    INTERNATIONAL JOURNAL OF ENVIRONMENTAL ANALYTICAL CHEMISTRY, 2012, 92 (09) : 1026 - 1035
  • [27] Dispersive liquid-liquid microextraction coupled with high-performance liquid chromatography-diode array detection for the determination of N-methyl carbamate pesticides in vegetables
    Lin, Xiangyun
    Chen, Xiaohui
    Huo, Xin
    Yu, Zhiguo
    Bi, Kaishun
    Li, Qing
    JOURNAL OF SEPARATION SCIENCE, 2011, 34 (02) : 202 - 209
  • [28] Using second-order calibration method based on trilinear decomposition algorithms coupled with high performance liquid chromatography with diode array detector for determination of quinolones in honey samples
    Yu, Yong-Jie
    Wu, Hai-Long
    Shao, Sheng-Zhi
    Kang, Chao
    Zhao, Juan
    Wang, Yu
    Zhu, Shao-Hua
    Yu, Ru-Qin
    TALANTA, 2011, 85 (03) : 1549 - 1559
  • [29] Identification of protein binders in works of art by high-performance liquid chromatography-diode array detector analysis of their tryptic digests
    Fremout, Wim
    Sanyova, Jana
    Saverwyns, Steven
    Vandenabeele, Peter
    Moens, Luc
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2009, 393 (08) : 1991 - 1999
  • [30] Analysis of environmental samples by application of multivariate curve resolution on fused high-performance liquid chromatography-diode array detection mass spectrometry data
    Pere-Trepat, Emma
    Tauler, Roma