Piecewise direct standardization assisted with second-order calibration methods to solve signal instability in high-performance liquid chromatography-diode array detection systems

被引:6
|
作者
Chen, Yue [1 ]
Wu, Hai-Long [1 ]
Wang, Tong [1 ]
Liu, Bing-Bing [1 ]
Ding, Yu-Jie [1 ]
Yu, Ru-Qin [1 ]
机构
[1] Hunan Univ, Coll Chem & Chem Engn, State Key Lab Chemo Biosensing & Chemometr, Changsha 410082, Hunan, Peoples R China
关键词
High performance liquid; chromatography-diode array detection; Alternating trilinear decomposition; Alternating trilinear decomposition assisted; multivariate curve resolution; Piecewise direct standardization; Signal instability; Second-order advantage; MULTIVARIATE CALIBRATION; HPLC-DAD; PESTICIDES; RESOLUTION; ADULTERATION; ALGORITHMS; ADVANTAGE;
D O I
10.1016/j.chroma.2022.462851
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
In this paper, in order to solve signal instability of high-performance liquid chromatography-diode array detection (HPLC-DAD) data and maintain the second-order advantage, this work proposed piecewise direct standardization (PDS) assisted with second-order calibration methods to analyze two different complex HPLC-DAD data with signal instability, including simulated HPLC-DAD data and the data of pesticide residues in saffron. Accurate quantitative results of target analytes can be obtained by PDS combined with alternating trilinear decomposition algorithm (ATLD) and alternating trilinear decomposition assisted multivariate curve resolution algorithm (ATLD-MCR) in the presence of signal instability with time shifts and changes of peak shape. Quantitative results of the model after calibration transfer are better than those of the model established by calibration sets and prediction sets with signal instability using ATLD algorithm and ATLD-MCR algorithm under different situations. Meanwhile, t-test was used to judge whether there are significant differences between these quantitative results of models. The performances of MCR-ALS algorithm were compared with that of PDS-ATLD method and PDS-ATLD-MCR method and the proposed methods have greater potential in dealing with the case of signal instability with time shifts and changes of peak shape. In a word, this methodology can reduce the number of calibration samples for recalibration and modeling, improve the efficiency of experiment, conform to the principle of green chemistry, and obtain satisfactory quantitative results in the presence of signal instability with time shifts and changes of peak shape. (c) 2022 Elsevier B.V. All rights reserved.
引用
收藏
页数:9
相关论文
共 50 条
  • [1] Fast chromatographic method for the determination of dyes in beverages by using high performance liquid chromatography-Diode array detection data and second order algorithms
    Culzoni, Maria J.
    Schenone, Agustina V.
    Llamas, Natalia E.
    Garrido, Mariano
    Di Nezio, Maria S.
    Fernandez Band, Beatriz S.
    Goicoechea, Hector C.
    JOURNAL OF CHROMATOGRAPHY A, 2009, 1216 (42) : 7063 - 7070
  • [2] Simultaneous determination of nine tyrosine kinase inhibitors in three complex biological matrices by using high-performance liquid chromatography-diode array detection combined with a second-order calibration method
    Wang, Zhao-Yang
    Wu, Hai-Long
    Chang, Yue-Yue
    Wang, Tong
    Chen, Wei
    Tong, Gao-Yan
    Yu, Ru-Qin
    JOURNAL OF SEPARATION SCIENCE, 2021, 44 (21) : 3914 - 3923
  • [3] Solving signal instability to maintain the second-order advantage in the resolution and determination of multi-analytes in complex systems by modeling liquid chromatography-mass spectrometry data using alternating trilinear decomposition method assisted with piecewise direct standardization
    Gu, Hui-Wen
    Wu, Hai-Long
    Yin, Xiao-Li
    Li, Shan-Shan
    Liu, Ya-Juan
    Xia, Hui
    Xie, Li-Xia
    Yu, Ru-Qin
    Yang, Peng-Yuan
    Lu, Hao-Jie
    JOURNAL OF CHROMATOGRAPHY A, 2015, 1407 : 157 - 168
  • [4] Second-order calibration for simultaneous determination of pharmaceuticals in water samples by solid-phase extraction and fast high-performance liquid chromatography with diode array detector
    Akvan, Nadia
    Parastar, Hadi
    CHEMOMETRICS AND INTELLIGENT LABORATORY SYSTEMS, 2014, 137 : 146 - 154
  • [5] Determination of Parabens in Cosmetics by Liquid-Phase Microextractions and High-Performance Liquid Chromatography-Diode Array Detection
    Jain, Archana
    Soni, Soumitra
    Verma, Krishna K.
    JOURNAL OF LIQUID CHROMATOGRAPHY & RELATED TECHNOLOGIES, 2015, 38 (01) : 82 - 91
  • [6] Determination of cyprodinil and fludioxonil in the fermentative process of must by high-performance liquid chromatography-diode array detection
    Vaquero-Fernandez, Luis
    Saenz-Hernaez, Ana
    Sanz-Asensio, Jesus
    Fernandez-Zurbano, Purificacion
    Sainz-Ramirez, Miguel
    Pons-Jubera, Begona
    Lopez-Alonso, Miguel
    Epifanio-Fernandez, Sara-Isabel
    Martinez-Soria, Maria-Teresa
    JOURNAL OF THE SCIENCE OF FOOD AND AGRICULTURE, 2008, 88 (11) : 1943 - 1948
  • [7] Chemometrics-assisted high performance liquid chromatography-diode array detection strategy to solve varying interfering patterns from different chromatographic columns and sample matrices for beverage analysis
    Yin, Xiao-Li
    Wu, Hai-Long
    Gu, Hui-Wen
    Hu, Yong
    Wang, Li
    Xia, Hui
    Xiang, Shou-Xia
    Yu, Ru-Qin
    JOURNAL OF CHROMATOGRAPHY A, 2016, 1435 : 75 - 84
  • [8] Simultaneous determination of eight flavonoids in propolis using chemometrics-assisted high performance liquid chromatography-diode array detection
    Sun, Yan-Mei
    Wu, Hai-Long
    Wang, Jian-Yao
    Liu, Zhi
    Zhai, Min
    Yu, Ru-Qin
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2014, 962 : 59 - 67
  • [9] Determination of pesticides and metabolites in wine by high performance liquid chromatography and second-order calibration methods
    Braga, Jez Willian B.
    Bottoli, Carla B. G.
    Jardim, Isabel C. S. F.
    Goicoechea, Hector C.
    Olivieri, Alejandro C.
    Poppi, Ronei J.
    JOURNAL OF CHROMATOGRAPHY A, 2007, 1148 (02) : 200 - 210