Comparison of corneal dynamic parameters and tomographic measurements using Scheimpflug imaging in keratoconus

被引:57
|
作者
Chan, Tommy C. Y. [1 ]
Wang, Yu Meng [1 ]
Yu, Marco [2 ]
Jhanji, Vishal [1 ,3 ]
机构
[1] Chinese Univ Hong Kong, Dept Ophthalmol & Visual Sci, Hong Kong, Hong Kong, Peoples R China
[2] Hang Seng Management Coll, Dept Math & Stat, Hong Kong, Hong Kong, Peoples R China
[3] Univ Pittsburgh, UPMC Eye Ctr, Pittsburgh, PA USA
关键词
FORME-FRUSTE KERATOCONUS; SUBCLINICAL KERATOCONUS; FELLOW EYES; INTRAOCULAR-PRESSURE; PACHYMETRY; ELEVATION; PENTACAM; HEALTHY; BIOMECHANICS; ORIENTATION;
D O I
10.1136/bjophthalmol-2017-310355
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Aim To compare the diagnostic ability of corneal tomography and corneal dynamic response measurements in normal and keratoconus eyes. Methods Consecutive patients with grade II-III keratoconus and age-matched normal subjects were recruited. Corneal imaging was performed using Pentacam (Oculus Optikgerate, Wetzlar, Germany) and Corvis (Oculus Optikgerate). A beta version of Corvis software was used with three additional parameters: maximal change of arc length, deformation amplitude (DA) ratio 1 and DA ratio 2. Diagnostic ability of both devices to differentiate normal and keratoconus eyes was evaluated using receiver-operating characteristic (ROC) curves. The areas under the ROC curve (AUC) and partial AUC (pAUC) for specificity >= 80% for each parameter of Corvis and final D value of Belin/Ambrosio Enhanced Ectasia Display (BAD) were compared. Results Forty-two eyes of 42 patients (21 patients with keratoconus and 21 normal subjects) were included. Both groups were age matched (p=0.760). The ROC analysis showed that the final D value of BAD had the highest AUC (0.994) and pAUC (0.194). Maximum inverse radius had the highest AUC (0.954) but a relatively lower pAUC (0.158), while DA ratio 2 had the second highest AUC (0.946) together with the highest pAUC (0.177) among Corvis parameters. There was no significant difference between AUC and pAUC of BAD compared with those of DA ratio 1 (p=0.162) and DA ratio 2 (p=0.208). Conclusions The results of our study suggest that Corvis measurements have the potential to differentiate keratoconus and normal eyes. The diagnostic ability of novel parameters on Corvis was comparable to Pentacam.
引用
收藏
页码:42 / 47
页数:6
相关论文
共 50 条
  • [31] The precision and agreement of corneal thickness and keratometry measurements with SS-OCT versus Scheimpflug imaging
    Zhao, Yune
    Chen, Ding
    Savini, Giacomo
    Wang, Qing
    Zhang, Hongfang
    Jin, Yili
    Song, Benhao
    Ning, Rui
    Huang, Jinhai
    Mei, Chenyang
    EYE AND VISION, 2020, 7 (01)
  • [32] Comparison of Two Scheimpflug Systems in the Measurements of Eyes with Corneal Diameter Smaller than 11.1 mm
    Niu, Lingling
    Ding, Lan
    Qian, Yishan
    Zhou, Xingtao
    OPHTHALMOLOGY AND THERAPY, 2023, 12 (01) : 125 - 138
  • [33] Precision of Corneal Thickness Measurements Obtained Using the Scheimpflug-Placido Imaging and Agreement with Ultrasound Pachymetry
    Huang, Jinhai
    Savini, Giacomo
    Wang, Chengfang
    Lu, Weicong
    Gao, Rongrong
    Li, Yuanguang
    Wang, Qinmei
    Zhao, Yune
    JOURNAL OF OPHTHALMOLOGY, 2015, 2015
  • [34] Effect of Prostaglandin Analogues on Corneal Biomechanical Parameters Measured With a Dynamic Scheimpflug Analyzer
    Yasukura, Yuichi
    Miki, Atsuya
    Maeda, Naoyuki
    Koh, Shizuka
    Nishida, Kohji
    JOURNAL OF GLAUCOMA, 2021, 30 (11) : 996 - 1000
  • [35] Correlation of corneal thickness and volume with intraoperative phacoemulsification parameters using Scheimpflug imaging and optical coherence tomography
    Wong, Melissa M.
    Shukla, Anita N.
    Munir, Wuqaas M.
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2014, 40 (12) : 2067 - 2075
  • [36] Comparison of anterior segment measurements using rotating Scheimpflug imaging and partial coherence interferometry
    Mohammad Soleimani
    Hassan Hashemi
    Shiva Mehravaran
    Mehdi Khabazkhoob
    Mohammad Hassan Emamian
    Mohammad Shariati
    Akbar Fotouhi
    International Journal of Ophthalmology, 2013, 6 (04) : 510 - 514
  • [37] Comparison of anterior segment measurements using rotating Scheimpflug imaging and partial coherence interferometry
    Soleimani, Mohammad
    Hashemi, Hassan
    Mehravaran, Shiva
    Khabazkhoob, Mohdi
    Emamian, Mohammad Hassan
    Shariati, Mohammad
    Fotouhi, Akbar
    INTERNATIONAL JOURNAL OF OPHTHALMOLOGY, 2013, 6 (04) : 510 - 514
  • [38] Comparison of corneal measurements in keratoconic eyes using rotating Scheimpflug camera and scanning-slit topography
    Naderan, Mohammad
    Shoar, Saeed
    Naderan, Morteza
    Kamaleddin, Mohammad Anmin
    Rajabi, Mohammad Taher
    INTERNATIONAL JOURNAL OF OPHTHALMOLOGY, 2015, 8 (02) : 275 - 280
  • [39] Comparison of corneal measurements in keratoconic eyes using rotating Scheimpflug camera and scanning-slit topography
    Mohammad Naderan
    Saeed Shoar
    Morteza Naderan
    Mohammad Amin Kamaleddin
    Mohammad Taher Rajabi
    International Journal of Ophthalmology, 2015, (02) : 275 - 280
  • [40] Comparison of corneal tomographic parameters between Hispanic and non-Hispanic patients
    Uhm, So Yeon
    Do, Trong Phat
    Montoya, Rafael Heinz
    Lam, Brandon
    Kheirkhah, Ahmad
    GRAEFES ARCHIVE FOR CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2024, 262 (01) : 143 - 148