Comparison of corneal dynamic parameters and tomographic measurements using Scheimpflug imaging in keratoconus

被引:57
|
作者
Chan, Tommy C. Y. [1 ]
Wang, Yu Meng [1 ]
Yu, Marco [2 ]
Jhanji, Vishal [1 ,3 ]
机构
[1] Chinese Univ Hong Kong, Dept Ophthalmol & Visual Sci, Hong Kong, Hong Kong, Peoples R China
[2] Hang Seng Management Coll, Dept Math & Stat, Hong Kong, Hong Kong, Peoples R China
[3] Univ Pittsburgh, UPMC Eye Ctr, Pittsburgh, PA USA
关键词
FORME-FRUSTE KERATOCONUS; SUBCLINICAL KERATOCONUS; FELLOW EYES; INTRAOCULAR-PRESSURE; PACHYMETRY; ELEVATION; PENTACAM; HEALTHY; BIOMECHANICS; ORIENTATION;
D O I
10.1136/bjophthalmol-2017-310355
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Aim To compare the diagnostic ability of corneal tomography and corneal dynamic response measurements in normal and keratoconus eyes. Methods Consecutive patients with grade II-III keratoconus and age-matched normal subjects were recruited. Corneal imaging was performed using Pentacam (Oculus Optikgerate, Wetzlar, Germany) and Corvis (Oculus Optikgerate). A beta version of Corvis software was used with three additional parameters: maximal change of arc length, deformation amplitude (DA) ratio 1 and DA ratio 2. Diagnostic ability of both devices to differentiate normal and keratoconus eyes was evaluated using receiver-operating characteristic (ROC) curves. The areas under the ROC curve (AUC) and partial AUC (pAUC) for specificity >= 80% for each parameter of Corvis and final D value of Belin/Ambrosio Enhanced Ectasia Display (BAD) were compared. Results Forty-two eyes of 42 patients (21 patients with keratoconus and 21 normal subjects) were included. Both groups were age matched (p=0.760). The ROC analysis showed that the final D value of BAD had the highest AUC (0.994) and pAUC (0.194). Maximum inverse radius had the highest AUC (0.954) but a relatively lower pAUC (0.158), while DA ratio 2 had the second highest AUC (0.946) together with the highest pAUC (0.177) among Corvis parameters. There was no significant difference between AUC and pAUC of BAD compared with those of DA ratio 1 (p=0.162) and DA ratio 2 (p=0.208). Conclusions The results of our study suggest that Corvis measurements have the potential to differentiate keratoconus and normal eyes. The diagnostic ability of novel parameters on Corvis was comparable to Pentacam.
引用
收藏
页码:42 / 47
页数:6
相关论文
共 50 条
  • [11] Assessment of Corneal Parameters in Patients with Constitutional Thinness Using Scheimpflug Imaging
    Gunes, Alime
    Bas, Funda Yildirim
    Arslan, Bahriye
    Tok, Levent
    Tok, Ozlem
    Salman, Zeliha
    SEMINARS IN OPHTHALMOLOGY, 2018, 33 (02) : 175 - 178
  • [12] Comparison of a Scheimpflug imaging with other screening indices in diagnosing keratoconus and keratoconus suspect
    Huo, Yan
    Xie, Ruisi
    Chen, Xuan
    Li, Shuangcheng
    Zou, Haohan
    Liu, Yutong
    Wang, Yan
    SCIENTIFIC REPORTS, 2024, 14 (01):
  • [13] Comparison of Corneal Tomography and a New Combined Tomographic Biomechanical Index in Subclinical Keratoconus
    Chan, Tommy C. Y.
    Wang, Yu Meng
    Yu, Marco
    Jhanji, Vishal
    JOURNAL OF REFRACTIVE SURGERY, 2018, 34 (09) : 616 - +
  • [14] Scheimpflug Imaging Parameters Associated with Tear Mediators and Bronchial Asthma in Keratoconus
    Pasztor, Dorottya
    Kolozsvari, Bence Lajos
    Csutak, Adrienne
    Berta, Andras
    Hassan, Ziad
    Kettesy, Beata Andrea
    Gogolak, Peter
    Fodor, Mariann
    JOURNAL OF OPHTHALMOLOGY, 2016, 2016
  • [15] Comparison of Ectasia Detection in Early Keratoconus Using Scheimpflug-Based Corneal Tomography and Biomechanical Assessments
    Wallace, Henry B.
    Vellara, Hans R.
    Gokul, Akilesh
    Mcghee, Charles N. J.
    Meyer, Jay J.
    CORNEA, 2023, 42 (12) : 1528 - 1535
  • [16] Comparison of corneal measurements in keratoconus eyes with two swept-source-optical coherence tomography devices and a Scheimpflug device
    Bograd, Alexandra
    Himmel, Isabelle
    Pfister, Isabel B.
    Seiler, Theo G.
    Frueh, Beatrice E.
    Tappeiner, Christoph
    GRAEFES ARCHIVE FOR CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2023, 262 (3) : 891 - 901
  • [17] Comparison of corneal measurements in keratoconus eyes with two swept-source-optical coherence tomography devices and a Scheimpflug device
    Alexandra Bograd
    Isabelle Himmel
    Isabel B. Pfister
    Theo G. Seiler
    Beatrice E. Frueh
    Christoph Tappeiner
    Graefe's Archive for Clinical and Experimental Ophthalmology, 2024, 262 : 891 - 901
  • [18] Assessment of corneal biomechanical parameters in healthy and keratoconic eyes using dynamic bidirectional applanation device and dynamic Scheimpflug analyzer
    Herber, Robert
    Ramm, Lisa
    Spoerl, Eberhard
    Raiskup, Frederik
    Pillunat, Lutz E.
    Terai, Naim
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2019, 45 (06) : 778 - 788
  • [19] Evaluation of Corneal Parameters with Scheimpflug Imaging in Patients with Rheumatoid Arthritis
    Cingu, Abdullah Kursat
    Cinar, Yasin
    Turkcu, Fatih Mehmet
    Sahin, Muhammed
    Kaya, Savas
    Bozkurt, Mehtap
    Sahin, Alparslan
    Yuksel, Harun
    Ari, Seyhmus
    Caca, Ihsan
    OCULAR IMMUNOLOGY AND INFLAMMATION, 2013, 21 (05) : 360 - 365
  • [20] Assessment of Corneal Parameters with Scheimpflug Imaging in Patients with Ankylosing Spondylitis
    Gunes, Alime
    Inal, Esra Erkol
    Tok, Levent
    Tok, Ozlem
    SEMINARS IN OPHTHALMOLOGY, 2017, 32 (03) : 276 - 280