Comparison of corneal dynamic parameters and tomographic measurements using Scheimpflug imaging in keratoconus

被引:57
|
作者
Chan, Tommy C. Y. [1 ]
Wang, Yu Meng [1 ]
Yu, Marco [2 ]
Jhanji, Vishal [1 ,3 ]
机构
[1] Chinese Univ Hong Kong, Dept Ophthalmol & Visual Sci, Hong Kong, Hong Kong, Peoples R China
[2] Hang Seng Management Coll, Dept Math & Stat, Hong Kong, Hong Kong, Peoples R China
[3] Univ Pittsburgh, UPMC Eye Ctr, Pittsburgh, PA USA
关键词
FORME-FRUSTE KERATOCONUS; SUBCLINICAL KERATOCONUS; FELLOW EYES; INTRAOCULAR-PRESSURE; PACHYMETRY; ELEVATION; PENTACAM; HEALTHY; BIOMECHANICS; ORIENTATION;
D O I
10.1136/bjophthalmol-2017-310355
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Aim To compare the diagnostic ability of corneal tomography and corneal dynamic response measurements in normal and keratoconus eyes. Methods Consecutive patients with grade II-III keratoconus and age-matched normal subjects were recruited. Corneal imaging was performed using Pentacam (Oculus Optikgerate, Wetzlar, Germany) and Corvis (Oculus Optikgerate). A beta version of Corvis software was used with three additional parameters: maximal change of arc length, deformation amplitude (DA) ratio 1 and DA ratio 2. Diagnostic ability of both devices to differentiate normal and keratoconus eyes was evaluated using receiver-operating characteristic (ROC) curves. The areas under the ROC curve (AUC) and partial AUC (pAUC) for specificity >= 80% for each parameter of Corvis and final D value of Belin/Ambrosio Enhanced Ectasia Display (BAD) were compared. Results Forty-two eyes of 42 patients (21 patients with keratoconus and 21 normal subjects) were included. Both groups were age matched (p=0.760). The ROC analysis showed that the final D value of BAD had the highest AUC (0.994) and pAUC (0.194). Maximum inverse radius had the highest AUC (0.954) but a relatively lower pAUC (0.158), while DA ratio 2 had the second highest AUC (0.946) together with the highest pAUC (0.177) among Corvis parameters. There was no significant difference between AUC and pAUC of BAD compared with those of DA ratio 1 (p=0.162) and DA ratio 2 (p=0.208). Conclusions The results of our study suggest that Corvis measurements have the potential to differentiate keratoconus and normal eyes. The diagnostic ability of novel parameters on Corvis was comparable to Pentacam.
引用
收藏
页码:42 / 47
页数:6
相关论文
共 50 条
  • [1] Evaluation of corneal biomechanics in keratoconus using dynamic ultra-high-speed Scheimpflug measurements
    Brettl, S.
    Zeitz, P. Franko
    Fuchsluger, T. A.
    OPHTHALMOLOGE, 2018, 115 (08): : 644 - 648
  • [2] Repeatability and reproducibility of corneal deformation response parameters of dynamic ultra-high-speed Scheimpflug imaging in keratoconus
    Herber, Robert
    Vinciguerra, Riccardo
    Lopes, Bernardo
    Raiskup, Frederik
    Pillunat, Lutz E.
    Vinciguerra, Paolo
    Ambrosio, Renato, Jr.
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2020, 46 (01) : 86 - 94
  • [3] Evaluation of Intereye Corneal Asymmetry in Patients with Keratoconus. A Scheimpflug Imaging Study
    Dienes, Lorant
    Kranitz, Kinga
    Juhasz, Eva
    Gyenes, Andrea
    Takacs, Agnes
    Mihaltz, Kata
    Nagy, Zoltan Z.
    Kovacs, Illes
    PLOS ONE, 2014, 9 (10):
  • [4] Comparisons of corneal biomechanical and tomographic parameters among thin normal cornea, forme fruste keratoconus, and mild keratoconus
    Tian, Lei
    Zhang, Di
    Guo, Lili
    Qin, Xiao
    Zhang, Hui
    Zhang, Haixia
    Jie, Ying
    Li, Lin
    EYE AND VISION, 2021, 8 (01)
  • [5] Correlation of corneal elevations measured by Scheimpflug corneal imaging with severity of keratoconus
    Medghalchi, Abdolreza
    Moghadam, Reza Soltani
    Akbari, Mitra
    Alizadeh, Yousef
    Soltanipour, Soheil
    Veisi, Heidar
    Khakpour, Yaser
    JOURNAL OF CURRENT OPHTHALMOLOGY, 2019, 31 (04): : 377 - 381
  • [6] Comparative evaluation of dual Scheimpflug imaging parameters in keratoconus, early keratoconus, and normal eyes
    Reddy, Jagadesh C.
    Rapuarto, Christopher J.
    Cater, Jacqueline R.
    Suri, Kunal
    Nagra, Parveen K.
    Hammersmith, Kristin M.
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2014, 40 (04) : 582 - 592
  • [7] Evaluation of Scheimpflug imaging parameters in subclinical keratoconus, keratoconus, and normal eyes
    Ucakhan, Omur O.
    Cetinkor, Volkan
    Ozkan, Muhip
    Kanpolat, Ayfer
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2011, 37 (06) : 1116 - 1124
  • [8] Assessment of Keratoconus Risk in Very Asymmetric Ectasia Using Corneal Tomographic and Biomechanical Parameters
    Zhang, Xiaoyu
    Ding, Lan
    Sun, Ling
    Sun, Bingqing
    Huang, Yangyi
    Qian, Yishan
    Zhou, Xingtao
    CLINICAL OPHTHALMOLOGY, 2023, 17 : 3569 - 3577
  • [9] Evaluation of corneal elevation in eyes with subclinical keratoconus and keratoconus using Galilei double Scheimpflug analyzer
    Jafarinasab, Mohammad Reza
    Feizi, Sepehr
    Karimian, Farid
    Hasanpour, Hossein
    EUROPEAN JOURNAL OF OPHTHALMOLOGY, 2013, 23 (03) : 377 - 384
  • [10] Corneal Power Measurements Using Scheimpflug Imaging in Eyes With Prior Corneal Refractive Surgery
    Holladay, Jack T.
    Hill, Warren E.
    Steinmueller, Andreas
    JOURNAL OF REFRACTIVE SURGERY, 2009, 25 (10) : 862 - 868