Comparative Survival of Uncemented Acetabular Components Following Primary Total Hip Arthroplasty

被引:65
作者
Howard, James L. [1 ]
Kremers, Hilal Maradit [1 ]
Loechler, Youlonda A. [1 ]
Schleck, Cathy D. [1 ]
Harmsen, William S. [1 ]
Berry, Daniel J. [1 ]
Cabanela, Miguel E. [1 ]
Hanssen, Arlen D. [1 ]
Pagnano, Mark W. [1 ]
Trousdale, Robert T. [1 ]
Lewallen, David G. [1 ]
机构
[1] Mayo Clin, Rochester, MN 55905 USA
关键词
CROSS-LINKED POLYETHYLENE; PRIMARY OSTEOARTHRITIS; YOUNGER PATIENTS; REGISTER; REPLACEMENT; REVISION; TERM; CEMENTLESS; WEAR; HYDROXYAPATITE;
D O I
10.2106/JBJS.J.00195
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background: Since their initial introduction in the early 1980s, uncemented acetabular components have become the preferred implant type for the majority of hip arthroplasties performed in the United States. The purpose of the present study was to compare differences in the survival of uncemented acetabular components following primary total hip arthroplasty. Methods: The study population included 7989 patients who had undergone 9584 primary total hip arthroplasties with twenty different types of uncemented acetabular components at the Mayo Clinic from January 1984 to December 2004. The overall rate of survival as well as the rate of survival free of revision for specific reasons (aseptic loosening, wear, osteolysis) were compared among the different components using age and sex-adjusted Cox proportional hazards regression models. Results: The risk of acetabular cup revision was significantly higher for beaded and hydroxyapatite-coated designs as compared with titanium wire mesh designs. Cross-linked polyethylene performed better than conventional polyethylene, but this finding did not reach significance. Elevated liners were associated with a significantly higher risk of cup revision due to aseptic loosening. Conclusions: There are significant differences in the long-term survival of different types of uncemented acetabular components following total hip arthroplasty. The increased risk of revisions in the second decade after the initial total hip arthroplasty is a concern and is largely due to a steady increase in revisions because of polyethylene wear, osteolysis, and component loosening more than ten years after the time of the index arthroplasty. Level of Evidence: Prognostic Level III. See Instructions to Authors for a complete description of levels of evidence.
引用
收藏
页码:1597 / 1604
页数:8
相关论文
共 50 条
  • [31] Does Activity Level After Primary Total Hip Arthroplasty Affect Aseptic Survival?
    Crawford, David A.
    Adams, Joanne B.
    Hobbs, Gerald R.
    Morris, Michael J.
    Berend, Keith R.
    Lombardi Jr, Adolph V.
    ARTHROPLASTY TODAY, 2021, 11 : 68 - 72
  • [32] Uncemented cups with and without screw holes in primary THA: a Swedish Hip Arthroplasty Register study with 22,725 hips
    Otten, Volker
    Mukka, Sebastian
    Nilsson, Kjell
    Crnalic, Sead
    Karrholm, Johan
    ACTA ORTHOPAEDICA, 2019, 90 (03) : 258 - 263
  • [33] Total hip arthroplasty following Girdlestone arthroplasty
    Ikebe, Satoshi
    Sonohata, Motoki
    Kitajima, Masaru
    Kawano, Shunsuke
    Mawatari, Masaaki
    JOURNAL OF ORTHOPAEDIC SCIENCE, 2018, 23 (03) : 532 - 537
  • [34] Midterm Results of Contemporary Uncemented Total Hip Arthroplasty in Patients 45 Years or Younger
    Hernandez, Nicholas
    Kim, Billy
    Cochrane, Niall H.
    Ryan, Sean P.
    Seyler, Thorsten M.
    ORTHOPEDICS, 2023, 46 (01) : E45 - +
  • [35] Venous thromboembolism following primary total hip arthroplasty
    Hitos, K.
    Fletcher, J. P.
    INTERNATIONAL ANGIOLOGY, 2009, 28 (03) : 215 - 221
  • [36] Early Death Following Primary Total Hip Arthroplasty
    Jones, Mark D.
    Parry, Michael C.
    Whitehouse, Michael R.
    Blom, Ashley W.
    JOURNAL OF ARTHROPLASTY, 2014, 29 (08) : 1625 - 1628
  • [37] Uncemented total hip arthroplasty can be used safely in the elderly population
    Lewis, P. M.
    Khan, F. J.
    Feathers, J. R.
    Lewis, M. H.
    Morris, K. H.
    Waddell, J. P.
    BONE & JOINT OPEN, 2021, 2 (05): : 293 - 300
  • [38] Foot drop following primary total hip arthroplasty
    O'Brien, Seamus
    Gallagher, Nicola
    Spence, David
    Bennett, Damien
    Dennison, Janice
    Beverland, David E.
    HIP INTERNATIONAL, 2020, 30 (02) : 135 - 140
  • [39] The accuracy of digital templating in uncemented total hip arthroplasty
    Holzer, Lukas A.
    Scholler, Georg
    Wagner, Stefan
    Friesenbichler, Joerg
    Maurer-Ertl, Werner
    Leithner, Andreas
    ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 2019, 139 (02) : 263 - 268
  • [40] Primary Total Hip Arthroplasty Using an Uncemented Wagner SL Stem in Elderly Patients With Dorr Type C Femoral Bone
    Zhen, Ping
    Liu, Jun
    Lu, Hao
    Chen, Hui
    Li, Xusheng
    Zhou, Shenghu
    INTERNATIONAL SURGERY, 2018, 103 (5-6) : 287 - 294