Comparative Survival of Uncemented Acetabular Components Following Primary Total Hip Arthroplasty

被引:65
|
作者
Howard, James L. [1 ]
Kremers, Hilal Maradit [1 ]
Loechler, Youlonda A. [1 ]
Schleck, Cathy D. [1 ]
Harmsen, William S. [1 ]
Berry, Daniel J. [1 ]
Cabanela, Miguel E. [1 ]
Hanssen, Arlen D. [1 ]
Pagnano, Mark W. [1 ]
Trousdale, Robert T. [1 ]
Lewallen, David G. [1 ]
机构
[1] Mayo Clin, Rochester, MN 55905 USA
来源
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME | 2011年 / 93A卷 / 17期
关键词
CROSS-LINKED POLYETHYLENE; PRIMARY OSTEOARTHRITIS; YOUNGER PATIENTS; REGISTER; REPLACEMENT; REVISION; TERM; CEMENTLESS; WEAR; HYDROXYAPATITE;
D O I
10.2106/JBJS.J.00195
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background: Since their initial introduction in the early 1980s, uncemented acetabular components have become the preferred implant type for the majority of hip arthroplasties performed in the United States. The purpose of the present study was to compare differences in the survival of uncemented acetabular components following primary total hip arthroplasty. Methods: The study population included 7989 patients who had undergone 9584 primary total hip arthroplasties with twenty different types of uncemented acetabular components at the Mayo Clinic from January 1984 to December 2004. The overall rate of survival as well as the rate of survival free of revision for specific reasons (aseptic loosening, wear, osteolysis) were compared among the different components using age and sex-adjusted Cox proportional hazards regression models. Results: The risk of acetabular cup revision was significantly higher for beaded and hydroxyapatite-coated designs as compared with titanium wire mesh designs. Cross-linked polyethylene performed better than conventional polyethylene, but this finding did not reach significance. Elevated liners were associated with a significantly higher risk of cup revision due to aseptic loosening. Conclusions: There are significant differences in the long-term survival of different types of uncemented acetabular components following total hip arthroplasty. The increased risk of revisions in the second decade after the initial total hip arthroplasty is a concern and is largely due to a steady increase in revisions because of polyethylene wear, osteolysis, and component loosening more than ten years after the time of the index arthroplasty. Level of Evidence: Prognostic Level III. See Instructions to Authors for a complete description of levels of evidence.
引用
收藏
页码:1597 / 1604
页数:8
相关论文
共 50 条
  • [21] Implant Survival of Constrained Acetabular Device in Primary Total Hip Arthroplasty Based on Data From the Finnish Arthroplasty Register
    Karvonen, Mikko
    Laaksonen, Inari
    Pulkkinen, Pekka
    Eskelinen, Antti
    Haapakoski, Jaason
    Puhto, Ari-Pekka
    Kettunen, Jukka
    Manninen, Mikko
    Makela, Keijo T.
    JOURNAL OF ARTHROPLASTY, 2020, 35 (01): : 219 - 223
  • [22] The uncemented primary bicontact stem in revision total hip arthroplasty in young patients
    Thorey, F.
    Lerch, M.
    Kiel, H.
    von Lewinski, G.
    Stukenborg-Colsman, C.
    Windhagen, H.
    ZEITSCHRIFT FUR ORTHOPADIE UND UNFALLCHIRURGIE, 2007, 145 : S40 - S43
  • [23] Danish survey of acetabular component positioning practice during primary total hip arthroplasty
    Cotong, Dana
    Troelsen, Anders
    Husted, Henrik
    Gromov, Kirill
    DANISH MEDICAL JOURNAL, 2017, 64 (04):
  • [24] Modern cementless acetabular cups in total hip arthroplasty performed for primary osteoarthritis: a comparative registry study
    Castagnini, Francesco
    Bordini, Barbara
    Cosentino, Monica
    Pardo, Francesco
    Gorgone, Mara
    Traina, Francesco
    ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 2024, 144 (11) : 4865 - 4872
  • [25] Revision for Aseptic Loosening of Highly Porous Acetabular Components in Primary Total Hip Arthroplasty: An Analysis of 20,993 Total Hip Replacements
    Hoskins, Wayne
    Rainbird, Sophia
    Holder, Carl
    Graves, Stephen E.
    Bingham, Roger
    JOURNAL OF ARTHROPLASTY, 2022, 37 (02): : 312 - 315
  • [26] Changes in acetabular orientation during total hip arthroplasty
    Schloemann, D. T.
    Edelstein, A., I
    Barrack, R. L.
    BONE & JOINT JOURNAL, 2019, 101B (06): : 45 - 50
  • [27] Evaluation and Treatment of Patients With Acetabular Osteolysis After Total Hip Arthroplasty
    Sheth, Neil P.
    Rozell, Joshua C.
    Paprosky, Wayne G.
    JOURNAL OF THE AMERICAN ACADEMY OF ORTHOPAEDIC SURGEONS, 2019, 27 (06) : E258 - E267
  • [28] Acetabular cup migration after primary cementless total hip arthroplasty in rheumatoid arthritis and its influencing factors: a comparative study with osteoarthritic hip
    Moon, Jun-Ki
    Jung, Ji-Won
    Kim, Yeesuk
    Yang, Jae-Hyuk
    Park, Ye-Soo
    Kim, Young-Ho
    INTERNATIONAL ORTHOPAEDICS, 2020, 44 (06) : 1047 - 1053
  • [29] Comparison of the two acetabular components in total hip arthroplasty: a meta-analysis
    Chu, Haikun
    Liu, Jiangtao
    Fang, Jinnv
    INTERNATIONAL JOURNAL OF CLINICAL AND EXPERIMENTAL MEDICINE, 2018, 11 (07): : 6674 - 6683
  • [30] Constrained Acetabular Components Used in Revision Total Hip Arthroplasty: A Registry Analysis
    Lewis, Peter L.
    Graves, Stephen E.
    de Steiger, Richard N.
    Cuthbert, Alana R.
    JOURNAL OF ARTHROPLASTY, 2017, 32 (10): : 3102 - 3107