Normal Characteristics of the Ocular Vestibular Evoked Myogenic Potential

被引:91
|
作者
Piker, Erin G. [1 ]
Jacobson, Gary P. [1 ]
McCaslin, Devin L. [1 ]
Hood, Linda J. [1 ]
机构
[1] Vanderbilt Univ, Dept Hearing & Speech Sci, Vanderbilt Bill Wilkerson Ctr Otolaryngol & Commu, Nashville, TN USA
关键词
Saccule; test-retest reliability; utricle; vestibular evoked myogenic potential; TEST-RETEST RELIABILITY; BONE-CONDUCTED VIBRATION; VESTIBULOOCULAR REFLEX; EXTRAOCULAR POTENTIALS; MIDLINE FOREHEAD; HEALTHY-SUBJECTS; SOUND; MUSCLES; FZ;
D O I
10.3766/jaaa.22.4.5
中图分类号
R36 [病理学]; R76 [耳鼻咽喉科学];
学科分类号
100104 ; 100213 ;
摘要
Background: Stimulus-evoked electromyographic changes can be recorded from the extraocular muscles. These short-latency negative-polarity evoked myogenic potentials are called ocular vestibular evoked myogenic potentials (oVEMPs). To date there has not yet been a large-scale study examining the effects of age on the amplitude, latency, threshold, and interaural differences of the oVEMP to air-conducted stimuli. Further, before the oVEMP can become a useful clinical tool, the test-retest reliability of the response must be established. The oVEMP response, once more completely understood, may provide diagnostic information that is complementary to the cervical vestibular evoked myogenic potential (cVEMP; i.e., sternocleidomastoid muscle). Purpose: To describe the normal characteristics of oVEMP in a cohort of age-stratified subjects, to assess the test-retest reliability of the oVEMP, and to determine if reference contamination occurs using a common recommended infraorbital reference electrode derivation. Research Design: A prospective, descriptive study design was used for an investigation with a threefold purpose in which oVEMP recordings were made from the extraocular muscles (e.g., inferior oblique muscle). Study Sample: Fifty otologically and neurologically normal adults and children served as subjects. Subjects ranged in age from 8 to 88 yr. Data Collection and Analysis: In Investigation 1, oVEMPs were recorded from the ipsilateral and contralateral inferior oblique muscles for all subjects. The stimulus was a 95 dB nHL 500 Hz tone burst. Next, oVEMP thresholds were obtained. Amplitude, latency, and thresholds were tabulated, and descriptive statistics were used to calculate normative values. Age-related differences in oVEMP component latencies, amplitudes, interaural amplitude asymmetries (IAAs), and thresholds were determined using an analysis of variance. In Investigation 2, oVEMPs were recorded twice in 10 subjects, once (test) and once approximately 10 weeks later (retest). Test retest reliability for the oVEMP peak-to-peak amplitude, n1 latency, p1 latency, n1 threshold, and IAA were assessed with intraclass correlation coefficients (ICCs) calculated using a two-way random-effects, absolute-agreement model. In Investigation 3, a four-channel oVEMP recording was conducted in 10 subjects. Both observational methods and paired-sample t-tests were used to evaluate the effect that reference electrode location had on the oVEMP. Results: oVEMP responses were present bilaterally in 90% of our subjects. The upper limit of oVEMP amplitude asymmetry, defined as the mean plus two standard deviations, was 34% (mean = 14%, SD 10), and the mean n1 latency was 12.5 (SD 1.0) msec. The amplitude of the response significantly decreased and the threshold significantly increased with increasing age, with the greatest age effects occurring in subjects 50 yr and older. Test retest reliability was acceptable (ICCs for the measurement variables ranged from .53 to .87). Using conventional recommended recording techniques, evidence of reference contamination occurred for all subjects, resulting in a mean amplitude reduction of 30% (range = 18%-43%). Conclusions: Age results in systematic changes in oVEMP measurement parameters. The test-retest reliability is acceptable, and reference contamination averaging 30% is guaranteed using a second infraorbital electrode as the inverting input (i.e., reference electrode) for bipolar recordings. The oVEMP can be used as a complementary diagnostic tool to the cVEMP in evaluating subjects with suspected peripheral vestibular disorders.
引用
收藏
页码:222 / 230
页数:9
相关论文
共 50 条
  • [21] Electrode montage and gaze effects on ocular vestibular evoked myogenic potentials (oVEMPs)
    Govender, Sendhil
    Cheng, Petrina Y.
    Dennis, Danielle L.
    Colebatch, James G.
    CLINICAL NEUROPHYSIOLOGY, 2016, 127 (08) : 2846 - 2854
  • [22] The clinical course of vestibular neuritis from the point of view of the ocular vestibular evoked myogenic potential
    Manzari, L.
    Graziano, D.
    Zambonini, G.
    Faralli, M.
    Morone, G.
    Tramontano, M.
    JOURNAL OF LARYNGOLOGY AND OTOLOGY, 2022, 136 (02) : 129 - 136
  • [23] Ocular vestibular evoked myogenic potential (oVEMP) responses in acute vestibular neuritis
    Govender, Sendhil
    Colebatch, James G.
    CLINICAL NEUROPHYSIOLOGY, 2012, 123 (05) : 1054 - 1055
  • [24] Ocular Vestibular Evoked Myogenic Potentials in Response to Air-Conducted Sound and Bone-Conducted Vibration in Vestibular Schwannoma
    Kinoshita, Makoto
    Iwasaki, Shinichi
    Fujimoto, Chisato
    Inoue, Aki
    Egami, Naoya
    Chihara, Yasuhiro
    Ushio, Munetaka
    Yamasoba, Tatsuya
    OTOLOGY & NEUROTOLOGY, 2013, 34 (07) : 1342 - 1348
  • [25] Ocular Vestibular Evoked Myogenic Potentials
    Felipe, Lilian
    Kingma, Herman
    INTERNATIONAL ARCHIVES OF OTORHINOLARYNGOLOGY, 2014, 18 (01) : 77 - 79
  • [26] Modeling the vestibular evoked myogenic potential
    Luetkenhoener, Bernd
    Stoll, Wolfgang
    Basel, Tuerker
    JOURNAL OF THEORETICAL BIOLOGY, 2010, 263 (01) : 70 - 78
  • [27] Characterizing the impact of advancing age on 500 Hz tone-burst evoked ocular-vestibular evoked myogenic potentials
    Singh, Niraj Kumar
    Firdose, Husna
    EUROPEAN ARCHIVES OF OTO-RHINO-LARYNGOLOGY, 2021, 278 (11) : 4259 - 4268
  • [28] Otolithic Disease: Clinical Features and the Role of Vestibular Evoked Myogenic Potentials
    Curthoys, Ian S.
    Manzari, Leonardo
    SEMINARS IN NEUROLOGY, 2013, 33 (03) : 231 - 237
  • [29] Intersession Variations in Frequency Tuning of Ocular Vestibular Evoked Myogenic Potentials in Healthy Individuals
    Singh, Niraj Kumar
    Raul, Aradhana
    Malik, Garima
    Sao, Tulsi
    AMERICAN JOURNAL OF AUDIOLOGY, 2019, 28 (02) : 407 - 413
  • [30] Clinical application of vestibular evoked myogenic potential (VEMP)
    Murofushi, Toshihisa
    AURIS NASUS LARYNX, 2016, 43 (04) : 367 - 376